Grade 1, Grade 2 and Grade 3 are shorthand for a full set of laboratory tests. This guide explains what is tested, what is not, and how to confirm the grade on the exact SKU.
North American lock specifications keep returning to one phrase: ANSI/BHMA grade. The Builders Hardware Manufacturers Association develops these documents, the American National Standards Institute accredits them, and accredited laboratories certify individual products against them. Three grades exist — Grade 1 for heavy-duty commercial openings, Grade 2 for light commercial and upgraded residential duty, and Grade 3 for basic residential use — but the grade itself is only a summary. Behind it are defined cycles, operating torques, lever and knob pull loads, deadbolt torque, impact, security loading and finish performance, each set by the product family standard (A156.2 for bored locks, A156.13 for mortise locks, A156.5 for auxiliary deadbolts). A grade is meaningful only when an accredited laboratory certified that exact model and the certificate can be located in the BHMA public listing. This page explains the grading system, how to read evidence, and what our factory provides in writing for named smart lock SKUs per quotation.
| What it is | A North American performance system: BHMA writes the standards, ANSI accredits them, and independent laboratories certify individual lock models against them. |
| The grades | Grade 1 is heavy-duty commercial, Grade 2 light commercial and upgraded residential, Grade 3 basic residential. The grade is printed in the certified listing, not assumed from price or weight. |
| Cycles | Endurance scales from 200,000 operations at Grade 3 toward 800,000 and 1,000,000 at Grade 1, with the exact requirement set by the product standard the lock is tested under. |
| Strength tests | Grading also covers operating torque, lever and knob pull, deadbolt torque, tension, impact, key strength and security-related static loading, with limits defined per standard. |
| Finishes | Decorative and protective finishes are evaluated separately under ANSI/BHMA A156.18; the mechanical grade does not by itself guarantee salt-spray or tarnish performance. |
| Certification | Only the BHMA-certified program with an accredited laboratory label counts. Marketing phrases such as “Grade 1 equivalent” or “exceeds Grade 1” are not certification. |
| Our policy | For each quoted smart lock we provide the standard number, grade and certificate for the named SKU. We never imply certification for unlisted models or for the cloud platform. |
Match the grade to opening duty and expected abuse. High-traffic public doors specify Grade 1; controlled offices and apartments commonly accept Grade 2; Grade 3 stays on residential doors. The certified grade belongs to the SKU, not the brand catalog.
| Opening duty | Typical grade | Why specifiers choose it |
|---|---|---|
| Public corridors, schools, transit | Grade 1 | Highest cycle, torque and pull margins absorb continuous and sometimes abusive use. |
| Hotel guest floors, commercial tenants | Grade 1 or 2 | Brand standards and duty volume set the line; Grade 1 still dominates new commercial specs. |
| Apartment units, small offices | Grade 2 | Proven endurance at controlled traffic, with a meaningful cost saving versus Grade 1. |
| Private offices, low-traffic rooms | Grade 2 or 3 | Abuse is limited, but electronic-access buyers often stay at Grade 2 for consistency. |
| Single-family residences | Grade 2 or 3 | Grade 2 buys commercial margins; Grade 3 meets the basic residential performance floor. |
| Back-of-house and storage doors | By exposure | Exterior and high-value rooms trend Grade 1; interior closets can match the rest of the building. |
ANSI/BHMA grades run across several product-family standards. Each lock is graded under the document that covers its construction, so a Grade 1 cylindrical lock and a Grade 1 mortise lock hold certificates to different standards and different tests.
| Opening | Typical door | Lock approach |
|---|---|---|
| Bored knob and lever locks | ANSI/BHMA A156.2 | Ask for the certificate naming the exact SKU and its grade for the bored lock assembly. |
| Mortise locks and trim | ANSI/BHMA A156.13 | Confirm grade plus the function code (for example F04 entry or F20 storeroom). |
| Auxiliary deadbolts | ANSI/BHMA A156.5 | The deadbolt is graded separately from the grip above or below it. |
| Electrified lock functions | ANSI/BHMA A156.25 | Electrical performance adds to the underlying mechanical grade; strikes use A156.31. |
| Panic and fire exit hardware | ANSI/BHMA A156.3 | Check grade together with the fire or panic listing of the labeled opening. |
| Materials and finishes | ANSI/BHMA A156.18 | Specify finish code and corrosion appearance testing independently of lock grade. |
Grade evidence is model-specific. For named smart lock SKUs our factory supplies the documentation pack below per quotation, covering the exact lock body, trim and credential reader being ordered rather than a generic brand claim.
| Component | Typical logic | Notes |
|---|---|---|
| BHMA certificate | An accredited laboratory certified the named SKU to the stated standard and grade. | Check SKU spelling, grade and standard before writing the spec. |
| Public listing entry | The model appears in the BHMA certified-product directory. | Cross-check online; listings can lapse or be withdrawn. |
| Laboratory test report | Records the cycle, torque, pull and finish results behind the certificate. | Use it in architect files and tender submissions. |
| Model mapping table | Shows which commercial name corresponds to which certified SKU. | Prevents shipping a look-alike that was never the tested unit. |
| Written confirmation letter | Our statement of the grade for the exact quoted models. | File it with the purchase order so claims stay SKU-specific. |
Grades are performance tiers defined within each BHMA product standard. Grade 1 targets heavy-duty commercial openings with the highest endurance, torque and pull requirements; Grade 2 targets light commercial and upgraded residential duty; Grade 3 covers basic residential use. Endurance alone runs from 200,000 operations at Grade 3 toward 800,000 or 1,000,000 at Grade 1 depending on the product family. The grade also rolls in strength, impact, security loading and finish tests, and it is certified per individual SKU by an accredited laboratory rather than assigned to a whole brand.
No. The grade certifies cycles, torque, pull, impact and related laboratory performance; it is not an attack rating and it does not mean unlimited resistance to forced entry. Deliberated attack resistance is covered by separate standards such as ANSI/BHMA A156.30 for high-security cylinders or by European EN 1627 door-set classes. A Grade 1 lock can still be defeated by a weak strike, short screws or a soft door frame, so the strike plate, screw length, frame and installation quality are part of real-world security and should be specified together.
A supplier can describe a product however it wishes in marketing, but a meaningful grade requires certification under the BHMA program by an accredited laboratory, with the model listed in the public certified-product directory. Phrases like “Grade 1 equivalent”, “commercial grade” or “exceeds Grade 1” carry no standardized meaning and should be treated as unverified. The safe procurement rule is simple: no certificate naming the exact SKU means no grade claim accepted into the specification, regardless of sample weight or finish quality.
It does not. ANSI/BHMA grades evaluate the mechanical and electrified locking hardware at the door. Credential readers, mobile apps, cloud uptime, encryption and data privacy are governed by other regimes — electrical safety and radio rules such as FCC or RED, and contractual security review for the platform. When a smart lock is electrified, the A156.25 evaluation covers electrical behavior of the locking device, but the access software is outside the grade. Evaluate hardware grade, radio compliance and platform security as three separate evidence sets.
Ask the supplier for the BHMA certificate and the certified-product listing entry before deposit, then compare three fields: the standard number, the grade, and the SKU or model name. Catalog names sometimes differ from certified names, so request a mapping table if the quotation uses a sales code. Cross-check the entry yourself in the free BHMA public directory, and keep the certificate and test report in the project file. Our factory supplies this pack for every quoted certified model, and we state in writing where a model is certified versus uncertified.
Send your door schedule and duty levels. We quote model by model and include the BHMA certificate, standard number and grade for each certified SKU in writing, with no blanket claims.
Request Spec Sheet + QuoteCertifications overviewLast updated: October 31, 2026 · Reviewed by the Smart Lock Factory editorial team