A156.25 adds electrical requirements on top of the mechanical standard a lock already meets. Understanding fail-safe and fail-secure behavior starts here.
ANSI/BHMA A156.25, the American National Standard for Electrified Locking Systems, defines how locking devices behave once motors, solenoids, position sensors and controlling inputs become part of the lock. Its premise matters: the device must first meet the mechanical standard for its family — A156.2 for a bored lock or A156.13 for a mortise lock — and A156.25 then layers on electrical endurance, voltage and current behavior, strength while energized or de-energized, and the all-important fail mode. Electric strikes and frame-mounted actuators have their own dedicated document, A156.31. A156.25 is also where fail-safe (unlocks on power loss) and fail-secure (stays locked on power loss) behavior is specified, a decision that life-safety and fire code reviewers examine carefully. This guide explains the standard, how smart locks use it, and the evidence we provide for named electrified SKUs per quotation.
| Scope | Electrified locking devices whose mechanical side is covered by the applicable BHMA product standard, plus integral input or controlling devices. |
| Layering | The lock first meets A156.2 or A156.13 mechanically; A156.25 adds electrical endurance, energized strength and control behavior on top. |
| Fail-safe | The device unlocks when power is lost; required where free egress or emergency entry must survive an outage, subject to the door code. |
| Fail-secure | The device stays locked when power is lost; mechanical override or free-egress inside must still satisfy the applicable life-safety code. |
| Tests | Electrical cycles, energized and de-energized strength, voltage and current behavior, overheating and operation at the rated supply. |
| Related standard | Electric strikes and frame-mounted actuators are covered separately under ANSI/BHMA A156.31, not under A156.25. |
| Evidence | The certificate should name the electrified SKU, its base mechanical standard, its grade and its fail mode, backed by the electrical test report. |
The choice is driven by life safety first, security second and operations third — in that order. Fire-rated and egress paths impose fail-safe or listed fail-secure alternatives, never convenience alone.
| Door situation | Typical mode | Reason |
|---|---|---|
| Stair and egress doors | Fail-safe or listed fail-secure with free egress | Occupants must be able to leave; the fire assembly listing governs. |
| Electric strike entrance | Fail-secure with mechanical egress hardware | Loss of power keeps intruders out while a push bar or lever exits freely. |
| Magnetic lock openings | Fail-safe with listed release and sensors | Maglocks have no mechanical hold; power loss must open the path. |
| Server and high-security rooms | Fail-secure with key override | Outage does not release the room; authorized staff use mechanical override. |
| Office tenant entry | Fail-secure plus request-to-exit | Security survives outages; staff egress via motion sensor or mechanical trim. |
| Elevator and delayed-egress setups | Per local fire marshal approval | Specialized sequences require listed components and explicit approval. |
A156.25 evidence sits alongside the mechanical certificate and the fire-door listing. Access-control designers trace all three documents for every controlled opening before wiring begins.
| Opening | Typical door | Lock approach |
|---|---|---|
| Electrified mortise | A156.13 body plus A156.25 electrical evaluation | Specify solenoid or motorized latch retraction and fail mode. |
| Electrified cylindrical | A156.2 chassis plus A156.25 | Confirm the listing names the electronic model, not only the chassis. |
| Electromagnetic locks | A156.25 with release and signaling accessories | Require fire-marshal-accepted egress sequence and listed parts. |
| Electric strikes | ANSI/BHMA A156.31 | Match fail mode, monitoring and strike strength to the lock. |
| Standalone smart locks | Mechanical grade plus radio and safety compliance | Battery-powered devices still need their radio and EMC evidence. |
| Request-to-exit devices | Listed switches and motion sensors | They are part of the egress logic, not afterthought accessories. |
Electrified projects need three evidence chains to agree: the mechanical grade, the A156.25 electrical behavior and the fire or egress listing. For named SKUs we supply the pack below per quotation and identify gaps that the system designer must close.
| Component | Typical logic | Notes |
|---|---|---|
| Mechanical certificate | A156.2 or A156.13 grade for the underlying lock. | Establishes the strength baseline. |
| A156.25 certificate | Electrical cycles, strength, fail mode and controls for the SKU. | Check fail-safe or fail-secure is stated explicitly. |
| Wiring and data sheet | Voltage, current, inrush, duty cycle and wire runs. | Prevents voltage drop that causes intermittent unlocks. |
| Fire listing cross-reference | Which labeled assemblies accept the electrified device. | Designer verifies against the door and frame labels. |
| Override description | Mechanical key or egress path during outage. | Required to reconcile security with life-safety review. |
Fail-safe devices unlock when electrical power is removed, ensuring the door can be entered or passed through during an outage, which suits openings whose primary duty is life safety. Fail-secure devices remain locked without power, preserving perimeter security, while free egress from inside is provided by mechanical levers, panic hardware or request-to-exit logic. The choice is not a vendor preference: it is constrained by the building code, the fire-door listing and the authority having jurisdiction. Maglocks are typically fail-safe with listed release sequences; strikes on perimeter doors are commonly fail-secure with mechanical egress.
No, it layers on top of them. A156.25 explicitly assumes the locking device first satisfies the mechanical product standard for its family — A156.2 for bored locks, A156.13 for mortise locks — and then adds requirements for the electrical function, endurance while energized, control inputs and failure behavior. A smart lock submittal should therefore show two certificates for the same model: the mechanical grade certificate and the electrified listing. If only one exists, ask whether the device was tested as a complete electrified configuration or as a bare chassis.
Electric strikes live in the frame rather than the door and interact with the latch through a keeper, so their mechanics, loading and installation are different from door-mounted electrified locks. ANSI/BHMA A156.31, Standard for Electric Strikes and Frame Mounted Actuators, defines their operational and finish requirements, while A156.25 addresses electrified locking systems on the door. A controlled opening that combines an electrified mortise lock or a conventional lock with an electric strike will reference both documents, and the two devices must be rated for the same grade level and fail logic.
Inrush current and holding current matter as much as nominal voltage. A solenoid may draw several times its holding current for a fraction of a second, and long wire runs with thin cable create voltage drop that causes buzz, weak throw or intermittent unlocking. Specify the supply voltage window, inrush and holding current, duty cycle (continuous versus intermittent), temperature range and whether the device is polarity-sensitive. The data sheet should name monitoring outputs for latch and door position as well. Power supplies, batteries and wire gauges are then sized with margin rather than guessed.
Yes, but only in configurations the door assembly listing allows and only when egress requirements are satisfied independently. A fail-secure electric latch retraction device can sit on a fire door if the door, frame and hardware listing names it and the inside trim always permits free egress without a key; magnetic locks require their own fail-safe release and signaling logic accepted by the authority having jurisdiction. Field substitutions — swapping in an unlisted strike or maglock — void the fire rating. Our quotations identify which named electrified SKUs are intended for labeled openings and provide the listing cross-references for design review.
Send your opening schedule with egress and fire labels. We quote named electrified SKUs with A156.25 and mechanical certificates, wiring data and explicit fail-safe or fail-secure statements.
Request Spec Sheet + QuoteCertifications overviewLast updated: October 31, 2026 · Reviewed by the Smart Lock Factory editorial team