Last updated: October 31, 2026 · Reviewed by export engineering

Training is not measured by how much a team remembers. It is measured by how many doors are cut correctly the first time.A course that raises confidence without raising the first-time fit rate has taught the wrong thing.

A distributor's margin disappears in three places: a lock returned because the door was measured wrong, a service call that could have been a parameter change, and a bid lost because nobody could read the specification. Training addresses all three, but only if it is built from the failures rather than from the product. This page sets out the modules, the four-step certification path, what a trainee physically leaves with, and the three numbers a partner should watch afterwards.

Purpose

What training is for: fewer failed installations

Most training in this industry teaches a catalogue. A sales team learns the six families, the features and the price ladder, then discovers on site that the customer's door is 38 mm thick and the model quoted was sized for a 45 mm leaf. The product knowledge was correct and useless, because it was not attached to a measurement.

This programme is built backwards from the eight installation failures a site team actually meets. Five of them start with a measurement that was never taken, and three with work done in the wrong sequence. That ratio sets the curriculum: the first modules are about reading a door, not about memorising a range. A trainee who can measure a leaf, note the handing and check a backset will prevent more failures than a trainee who can recite every finish option.

The second purpose is service economics. A parameter change that a partner's own technician can make is a ten-minute job; the same change routed through a factory support session is a booking, a time zone and a delay. Training moves the routine calls inside the partner's team, which is cheaper for the partner and frees the support tier for the exceptions it was designed for. The tier structure that benefits from this is described on installation support.

Modules

Module map: audience, duration, assessment

Eight modules cover the path from quote to service. They can be booked as a full programme or individually, and each has an assessment, because a module without one is a presentation. Session lengths below are the standard booking lengths; a cohort with a specific door stock can trade breadth for depth, and the final agenda is agreed in writing before the session.

ModuleAudienceDurationAssessmentDeliverable
Product familiesSales and specification1 session of 90 minTen-question mapping test: application to family to modelFamily comparison sheet with the constraint that eliminates each family
Cards and encodersSales, front desk, service1 session of 90 minEnrol a card, issue a room, revoke it, and read the audit recordCredential procedure card and a lost-card checklist
Software and gatewaysService and IT liaison1 session of 3 hConfigure a property, add a lock, and export a door reportSetup sheet with port, address and gateway placement notes
Door surveyInstallation and sales1 session of 3 h on siteMeasure 5 doors and complete a schedule unaidedSurvey form, tape-measure sequence and photo protocol
Installation practiceInstallation1 day of 6 hFit a lock on the practice door to the drawing, then pass a function checkInstallation checklist and a signed practice record
Fault diagnosisService1 session of 3 hDiagnose three staged faults from symptom to cause to fix, including a reader that reads at 2 cm and a pack that reads 1.5 V per cellFault code table and the escalation sheet for tier 2
Spare identificationService, stores, procurement1 session of 90 minMatch four parts to a model and a batch from labels and photographsPart family sheet and the matching rules used at spare parts
Tender documentsSales and bid teams1 session of 3 hAssemble a model document pack against a stated tender listDocument index and a redaction rule sheet

Two modules carry more weight than the others. Door survey is the one that changes a partner's first-time fit rate, and installation practice is the one that reveals whether the team's measuring habit survived the classroom. A cohort that skips the survey module and takes only installation practice will fit locks well to doors that were measured wrong, which is a faster route to a returned container rather than a shorter one.

The teaching material uses the SLK-2020 as the reference hotel model: a 306 mm x 75 mm x 15 mm body, a No. 2 hotel mortise, a 13.56 MHz reader and 4 x AA cells. A trainee measures that body against a real leaf, notes the handing and checks the backset, so the specification is attached to a door rather than to a brochure. Models in the same family are listed at hotel door locks.

For system integrators
Module 01

For system integrators

Wiring, reader protocols, network topology and the handover checklist. The integrator needs the access system to behave, not the lock to perform.

For locksmiths
Module 02

For locksmiths

Cylinder changes, override procedure, jam diagnosis and the tool list that matches each mortise case in the range.

For installers
Module 03

For installers

Measurement, cutting, spindle alignment, handover documents and the report an installer signs at the end of a job.

For service partners
Module 04

For service partners

Multi-site rollouts, firmware management and the escalation path when a site reports an event that does not match the record.

Certification

The certification path in four steps

Certification exists so that a distributor can answer a tender question about competence with a document rather than an assurance. The four steps below move a person from reading to doing, and each step has a condition that cannot be skipped. The path applies to an individual, not to a company, because a company does not fit a door.

StepFormatWhat the candidate doesCondition to advanceRecord issued
1 – Self-studyManual, checklists and fault table, read before any sessionWorks through the measurement and installation chapters and completes the practice questionsPractice questions submitted, with the incorrect answers marked and explainedStudy record against the revision of the manual used
2 – Online assessmentTimed assessment against the module mapAnswers the mapping and fault-diagnosis sections without reference materialPass mark agreed with the partner before the cohort startsAssessment result sheet, per module
3 – On-site workshopPractice door, real tools, the partner's own door stock where possibleMeasures, prepares and fits a lock, then runs the function check and completes the recordFit signed off by the trainer against the drawing and the checklistSigned practice record with photographs
4 – Supervised installationFirst 5 doors on a live site, with review after eachFits, records and hands over, with the deviation list completed5 doors recorded, no repeated failure, and a commissioning sheet countersignedInstaller certification, naming the models covered

The order matters more than the content. A candidate who fits a door before measuring one learns the lock and not the door, and that lesson is hard to reverse later. Step 4 is also the only step that cannot be run in a classroom: five doors recorded with no repeated failure is a statement about habit, not about knowledge, and it is the record a tender is most likely to ask for.

Outputs

What a trainee leaves with

A trainee should leave with documents that are used on a Tuesday afternoon, not a certificate in a drawer. The pack below is physical where a physical object helps and printed where a screen does not. Every item is tied to a situation the trainee will meet in the first month.

  • The installation manual for the models in the partner's range, at the revision current on the training date
  • A door survey form with the measurement sequence printed on it, so the order of steps is not left to memory
  • The eight-failure table, laminated for the site bag rather than filed in an office
  • A fault code table mapping the symptom on the door to the cause and the first three checks
  • The escalation sheet for tier 2 support, with the evidence a video session needs before it is booked
  • A practice door board or the partner's own trial leaf, retained after the session for new hires
  • The credential and encoder procedure, including the lost-card and room-move cases
  • The spare part family sheet, with the batch and model matching rules described on spare parts

The practice door is the item most often dropped and most often missed. A partner who keeps a prepared leaf with a correct pocket, a set strike and a known handing can train a new installer in an afternoon without booking a trainer or waiting for a cohort. The leaf costs less than one returned lock, and it turns training from an event into a habit.

Delivery

Delivery formats: on site, video and train the trainer

Three formats cover the same modules, and the choice depends on what the partner wants to own. On-site delivery puts a trainer in front of the partner's door stock. Video delivery trades that for frequency. Train the trainer builds a capability inside the partner's business, which is the only format that survives staff turnover without a new booking.

On site is the right choice for the first cohort and for any team installing a door type they have not met. The trainer sees the actual leaf, the frame and the strike, and the practice record reflects the partner's stock rather than a demonstration door. Video suits refresher sessions, new hires joining between cohorts, and service teams spread across several cities; it needs a camera at the door and a person willing to measure on screen. Train the trainer is a 2-day format for a partner who will run their own sessions: the candidate teaches a module under observation, is assessed on the teaching as well as the content, and leaves with the assessment key and the revision control rule.

All three formats use the same manual revision and the same assessment. That is deliberate. A certificate issued through video should mean what a certificate issued on site means, or the document is not worth showing to a client. The revision number on the manual is the anchor: if the manual changes, the assessment changes with it, and a certificate carries the revision it was earned against.

Measurement

How a partner measures whether training worked

A training programme that cannot be measured becomes a cost line that is cut in a slow quarter. Three numbers make it defensible, and all three can be produced from records a partner already keeps. The definitions below matter as much as the numbers, because a metric with a loose definition drifts until it flatters.

MetricDefinitionWhere the data comes fromWhat a good result looks like
First-time fit rateDoors that pass the function check on the first attempt, divided by doors attemptedThe door schedule, which already records pass or fail per doorA rising rate across a cohort window, with the failures concentrated on new door types rather than on new staff
Return rateUnits returned for a fit or function reason, divided by units installedThe partner's returns register, matched to the deviation listReturns traced to preparation rather than to product, which is the category training can reduce
Mean time to diagnoseHours from a reported symptom to a stated cause, per service ticketService log with timestamps, before and after the fault moduleA shorter time with a higher share of tickets closed without escalation

The first metric is the one to publish internally, because it is the one the installer controls. The second is the one to show a customer, because a low return rate is a commercial argument. The third is the one to watch for cost, because service hours are the line that grows quietly. None of the three should be measured over a single month: a cohort's effect appears after the first 100 doors, and a rate taken from 20 doors is noise with a decimal point. A 200-door project is the smallest fleet where the numbers settle.

Boundary

What training does not cover

Not included: certification of a company, door preparation as a trade, electrical installation, network design, and a guarantee that every trainee passes. Training produces records about people; it does not produce an accreditation for a business.

  • We do not certify a distributor as a business. Certificates name individuals and the models they were assessed on, because a company does not carry a tape measure.
  • We do not teach door preparation as a trade. Cutting a pocket, setting a strike and hanging a door belong to the door trade; the programme teaches the interface, the drawing and the check.
  • We do not cover electrical work or network design. Mains wiring, containment and the site's IT policy sit with licensed trades and the site owner.
  • We do not pass a trainee who fails the assessment. A re-sit is offered against the same revision; a certificate issued without a pass makes every other certificate worth less.
  • We do not replace site support. Training reduces routine calls; it does not remove the tier 2 session that a new door type will still need.

The boundary keeps the programme honest. A distributor who wants a badge for a tender should ask for the individual records, not a company certificate, because that is what a serious buyer checks. A distributor who wants an installer to learn carpentry should hire a carpenter and use the training for the lock.

Verification

What a partner can verify before booking a session

A booking is easier to justify when the partner can inspect what will be taught before paying for it. Six items are available before a session is confirmed, and each answers a question a distributor should ask anyway.

  • The module map with assessment methods, so the outcome of each session is known in advance
  • The manual revision that the session will use, so the content can be compared with the models on the partner's shelves
  • The practice record template that the trainer will sign, so the standard of a pass is visible
  • The fault code table as issued, so the service team can judge whether it covers the calls they take
  • The assessment key for each module, shared with the partner after the cohort rather than before
  • A reference cohort's before-and-after first-time fit rate, with the door count it was measured on

Ask for the revision number first. A module map without a revision is a brochure, and a manual without one cannot be compared across cohorts. The second question to ask is how the assessment is marked, because a pass mark agreed before the cohort starts is the difference between a training record and a receipt. Documents behind the programme are indexed at compliance documents, and templates for the partner's own use are at buyer resources.

FAQ

Training questions distributors ask first

How long before a new installer is productive?

The measured answer is five supervised doors after the workshop, because that is the step where habit replaces instruction. A team that only attends the classroom session is productive on prepared doors and uncertain on the first unusual one, which is exactly the door that generates a support call.

Can the training be delivered in our language?

Sessions are delivered in English by default, and a local trainer can be certified through the train-the-trainer format to deliver in the partner's language. The manual and the assessment stay in one revision, so a translated delivery does not create a second standard.

Do you train sales staff who will never fit a lock?

Yes, on the product family and survey modules. A sales person who cannot read a door schedule writes quotations that the installation team has to correct, and the correction usually happens after the order is placed.

What does a session cost?

It depends on the format, the number of modules and whether travel is involved, and it is quoted per cohort rather than per head. A train-the-trainer booking is priced differently from an on-site workshop because it produces a local capability rather than a single cohort's records.

Can we run the assessment ourselves?

After the train-the-trainer step, yes. The partner receives the assessment key, the marking rule and the revision control requirement. The certificate still names the revision of the manual it was earned against, which is what keeps an in-house assessment credible.

Is training included with a distributor agreement?

The first cohort is normally part of the onboarding conversation, and the scope is written into the agreement rather than assumed. Refresher sessions and additional modules are quoted. The commercial terms sit with the distributor programme.

What happens when the manual revision changes?

The assessment changes with it, and previously certified installers are notified of the modules affected. A certificate carries the revision it was earned against, so a buyer can see whether an installer was assessed on the current procedure or an older one.

Book a session around your next installation

Send the models you install, the door types on the next project, the number of installers and the date of the first door. We reply with the module plan, the practice record and the certification path that fits that project. Current MOQ policy and lead time on the training door stock are confirmed in writing with the quotation.

Request a quoteTalk to the training team
Your Cart
Your experience on this site will be improved by allowing cookies Cookie Policy
Chat on WhatsApp