Electronic cylinders and motor-driven locks are classified under EN 14846. Its digits cover electromechanical endurance, attack resistance, climate and electromagnetic behavior.
EN 14846, Building hardware — Locks and electronically operated locks and locking plates for use in doors, is the European standard for electromechanical and mechatronic locks: electronic euro-profile cylinders, motorized mortise locks, solenoid locks and their striking plates. It extends the EN 12209 classification model with electronic realities. Electromechanical durability runs to its own top grades — typically up to 100,000 test cycles for the electronic function, with some products also declaring higher mechanical-only cycles — while security uses a seven-grade scale measuring end load, side load, drilling time and deadbolt projection, and the environmental digit covers temperature, humidity and water exposure for indoor, sheltered outdoor and exposed outdoor use. Electromagnetic compatibility, battery behavior and fire suitability occupy further positions. As with EN 12209, a digit-1 fire suitability claim only becomes a rated doorset under EN 1634. This page explains the classification and the evidence our factory provides for named smart SKUs per quotation.
| Scope | Electronically operated locks, electronic cylinders and locking plates, including the electromechanical requirements added to the mechanical base. |
| Structure | An EN 12209-style multi-digit classification extended with electromechanical durability, environment, EMC, security and fire suitability. |
| Durability | Electronic-function endurance typically reaches 100,000 test cycles at the upper grades, distinct from any mechanical-only figure. |
| Security | Seven grades (0 through 6) with rising end and side loads, drilling resistance and deadbolt projection requirements. |
| Environment | Classes distinguish indoor climate, sheltered outdoor use with temperature and humidity cycling, and exposed outdoor conditions. |
| EMC and power | Electromagnetic compatibility, electrostatic discharge behavior and battery or supply behavior are classified within the scheme. |
| Evidence | Notified-laboratory classification report for the exact SKU, paired with RED radio evidence where the lock transmits and EN 1634 via the door for fire use. |
It answers whether a smart cylinder or motor lock will survive the door, the climate and the attack model — three questions that mechanical certificates and radio certificates do not answer on their own.
| Attribute | What the digit covers | Why projects care |
|---|---|---|
| Use category | Private versus public-building handling and abuse. | Public sites need the tougher category. |
| Electromechanical cycles | Electronic actuation endurance, up to roughly 100,000. | Sets service life of motor and gearbox. |
| Door mass | Suitability for heavy doors and closing forces. | Heavy fire doors demand the upper digit. |
| Fire suitability | Component claim for fire doors, used via EN 1634. | Never a standalone fire rating. |
| Security grade | Loads, drilling time and bolt projection, grades 0 to 6. | Insurance specs may demand a minimum grade. |
| Environment and EMC | Climate, moisture exposure and electromagnetic behavior. | Exterior and industrial sites set these digits. |
Electronic locks spread across retrofit and new-build markets. The classification is selected per opening, with exterior climate and security insurance requirements driving the highest digits.
| Opening | Typical door | Lock approach |
|---|---|---|
| Retrofit apartment doors | Electronic euro cylinder, no wiring, standard profile | Fast swap; verify length halves and cam type. |
| Hotel guest floors | Motorized mortise with high durability and fire digit | Paired with the doorset EN 1634 certificate. |
| Exterior office entrances | Sheltered or exposed outdoor environmental class | Temperature cycling and moisture matter more than cycles. |
| High-security rooms | Upper security grades with drilling resistance | Cross-checked against EN 1627 door class. |
| Access-controlled corridors | Solenoid or motor lock integrated into access control | EMC class and monitoring outputs reviewed. |
| Marine and poolside sites | Top environmental class plus corrosion evidence | Salt and humidity drive selection over headline security. |
For named electronic lock and cylinder SKUs we provide the pack below per quotation. Where radio modules are used, the EN 14846 evidence is supplemented with RED documentation rather than substituted by it.
| Component | Typical logic | Notes |
|---|---|---|
| Classification report | Full EN 14846 digit string from a recognized laboratory. | Primary document for European hardware specs. |
| Security-grade detail | End load, side load, drilling time and bolt projection for the grade. | Lets insurance reviewers compare requirements. |
| Environmental statement | Temperature, humidity and moisture class the device met. | Decides interior versus exterior suitability. |
| EMC and radio pack | EN 14846 EMC results plus RED evidence for BLE or other radio. | Two regimes, two evidence sets. |
| Battery and override data | Battery life assumptions, low-power behavior and mechanical override. | Critical for maintenance planning and egress review. |
It covers locks where electronics perform or control the locking action: electronic euro-profile cylinders that retrofit into existing mortise locks, motorized or solenoid mortise and rim locks, electromechanical locking plates and similar devices. A purely mechanical lock stays under EN 12209 even if an external reader is bolted beside it; once the lock or cylinder contains the actuator, credential check or motor, EN 14846 applies to the electromechanical assembly. Electronic locker and cabinet locks may reference the standard where their construction aligns, with product-specific standards checked separately.
The security scale runs through seven grades, 0 to 6, with grade 6 imposing the strongest requirements. The laboratory applies end load and side load to the locking elements, measures resistance to drilling with defined tool sets and times, and checks the minimum deadbolt projection, which rises from 10 mm at the low grades to 20 mm at the top. These are component attack tests on the lock, comparable across suppliers, but a door’s burglary resistance as a whole is still classified under EN 1627; the lock grade feeds that assembly class rather than replacing it.
Not by itself. Weather suitability lives in the environmental classification positions, which distinguish indoor use, sheltered outdoor use with defined temperature and humidity cycling, and exposed outdoor conditions; ingress of water is also commonly expressed separately through an IP code under IEC 60529. A top security grade says nothing about rain, and a top environmental class says nothing about attack. Exterior projects should specify both the environmental digit and an explicit IP rating (IP54, IP55 or higher depending on exposure), then confirm the combination on the exact SKU.
EN 14846 is a hardware performance standard; the RED (2014/53/EU) is the European regulatory regime for products that emit radio, covering safety, EMC and efficient use of spectrum through harmonized standards such as EN 301 489 and EN 300 328. A Bluetooth smart lock needs both: an EN 14846 classification to demonstrate lock-level performance and a Declaration of Conformity built on RED evidence for its radio module. Neither document substitutes for the other, and a fire-door project adds the EN 1634 assembly chain. Our quotation pack identifies which documents exist for each named SKU.
The classification and product design must show a safe, predictable low-power path. Typical implementations give early mobile or LED warnings, retain unlock operation through the last safe charge, and provide either an emergency power contact on the outside, a mechanical override cylinder, or an administrative opening procedure. On fire doors, egress remains mechanical regardless of battery state. Our data sheets state battery life assumptions under a defined daily-use model, the exact override method per SKU and whether keys or master cards are supplied; these details should be written into the site operating procedure rather than improvised at 2 a.m.
Share the required classification digits and whether doors are exterior or fire labeled. We supply the classification report, environmental statement and radio evidence for every named SKU.
Request Spec Sheet + QuoteCertifications overviewLast updated: October 31, 2026 · Reviewed by the Smart Lock Factory editorial team