Fail-safe hardware unlocks when power is cut so people can exit; fail-secure hardware stays locked to protect the space. Egress duties, fire strategy and asset risk — never preference — determine the mode for each opening.
Every electrified opening answers the same question: when power disappears, should this door be locked or unlocked? A fail-safe device requires power to remain locked, so cutting power (including a fire-alarm relay) releases the door for free egress; magnetic locks and many entrance strikes work this way, paired with request-to-exit sensors and backup power to control nuisance release. A fail-secure device requires power to unlock, so loss of power leaves the door secured against entry from outside while mechanical egress — a lever, crash bar or key override — still lets legitimate occupants leave; server rooms, cash rooms and pharmacies commonly specify fail-secure. Confusing the two is dangerous and sometimes illegal: fail-secure hardware on a required means of egress without proper free-egress mechanics can trap people in an emergency, while fail-safe hardware on a high-value room opens it to anyone during a power cut. Selection belongs to the architect or fire engineer per opening and local codes, with listed hardware, correct power and battery backup. Device listings, power requirements and override mechanics per SKU are confirmed in writing per quotation.
| Fail-safe | Locked while powered; unlocks on power loss to clear the egress path. |
| Fail-secure | Locked without power; needs power to release, protecting assets during outages. |
| Egress rule | Mechanical free exit must remain available regardless of the chosen mode. |
| Common devices | Maglocks and many strikes fail safe; selected strikes and bolts fail secure. |
| Backup power | UPS sizing decides how long either strategy behaves as intended. |
| Code ownership | The architect or fire engineer sets the mode, not the lock vendor. |
| Our policy | We supply listed devices for both modes and document power and override per opening. |
Means-of-egress doors favor fail-safe release under fire logic; asset rooms favor fail-secure with mechanical exit; many projects combine modes across the building and tie both into backup power.
| Opening | Typical mode | Reason |
|---|---|---|
| Main entrance maglock | Fail-safe | Fire strategy releases the entrance path. |
| Corridor egress door | Fail-safe | Clear exit on alarm or power loss. |
| Server or comms room | Fail-secure | Protect equipment during outages. |
| Cash or pharmacy room | Fail-secure | Asset protection with keyed exit. |
| Stairwell re-entry door | Per fire strategy | Code design balances egress and security. |
| Loading dock gate | Fail-secure often | Prevents tailgating during power events. |
The legal question is not lock versus lock but whether occupants can always leave. Even fail-secure openings must provide the code-required free egress mechanically — a lever or panic device — regardless of how entry is controlled.
| Decision factor | First option | Second option |
|---|---|---|
| State at power loss | Unlocked. | Locked against entry. |
| Power meaning | Power keeps the door locked. | Power unlocks on credential. |
| Primary goal | Life safety and egress clearance. | Asset and perimeter protection. |
| Typical hardware | Maglocks and fail-safe strikes. | Fail-secure strikes and electric bolts. |
| Backup concern | UPS prevents unwanted release. | UPS preserves scheduled entry. |
| Exit mechanics | Free exit follows release. | Free exit via lever, bar or key. |
Mode selection must follow the project’s fire and life-safety documentation. Confirm the following with the responsible designer before ordering electric hardware.
| Checkpoint | What to confirm | Why it matters |
|---|---|---|
| Egress classification | Whether the door is on the required means of egress. | Determines permissible modes and overrides. |
| Fire-alarm interface | Which relay must release under alarm. | Fail-safe doors tie into fire panels. |
| Mechanical exit | Lever, panic bar or key override present. | Fail-secure doors still need free egress. |
| Backup power | UPS capacity and monitoring for the access system. | Both modes fail predictably only with planning. |
| Device listing | The electric device listed for the intended function. | Strikes are ordered fail-safe or fail-secure specifically. |
The difference is entirely the door’s state when electrical power is removed. A fail-safe (also called fail-open in casual language) device is locked by power, so cutting power — whether by outage, emergency relay or damage — releases the leaf and clears the path, which is why maglocks on egress doors work this way. A fail-secure (fail-locked) device is unlocked by power, so without current it stays latched against the outside, preserving security during outages while occupants leave through a mechanical lever, panic bar or key override. The terminology matters in specs: “fail-safe” does not mean a safer lock for every purpose, and fail-secure does not mean occupants are trapped when the device is correctly installed with free-egress mechanics. We quote strikes, maglocks and bolts labeled with their exact failure mode and supply the wiring and power logic per opening in writing rather than relying on verbal shorthand.
Fail-secure entry control can be legal on doors that sit in the egress system only when the code-required means of free escape remains available without electrical power — for example a fail-secure strike on the outside-reader side paired with a mechanical lever or panic device that always withdraws the latch from inside. What is prohibited in nearly every modern code regime is a configuration where loss of power traps occupants because the only release was electric. Requirements vary by jurisdiction, occupancy and door classification, and some doors also need fire-alarm release regardless of the lock mode. The authority having jurisdiction and the project fire engineer own this decision; we provide listed hardware options and their egress mechanics per opening, and we never recommend ordering fail-secure devices on egress doors without the responsible designer’s written specification.
Electromagnetic locks are inherently fail-safe as devices: they hold the door only while energized, so any power loss releases them, which is precisely why they dominate fire-released entrance designs. That property also creates the operational duty to control unwanted release: request-to-exit sensors, delayed-egress logic where permitted, door alarms and properly sized UPS keep the building secure during short power events, while the fire panel can intentionally cut power for evacuation. Specifying a maglock also means accepting that a power failure opens the door — a lobby with no UPS becomes an open lobby during an outage. High-security entrances sometimes combine a maglock for egress duties with separate monitoring or secondary controls. We detail the maglock, release sensors, UPS sizing and alarm integration per entrance configuration rather than treating fail-safe behavior as a standalone feature.
A correctly installed fail-secure opening stays latched to the outside throughout the outage, protecting the room while authorized people inside leave by mechanical means — lever, crash bar or key — and new entries pause unless backup power carries the access system or a keyholder uses the mechanical override. That is exactly the behavior server rooms, pharmacies and cash rooms buy. The planning duties are threefold: size UPS for orderly operation of monitored doors, define keyholder response for prolonged outages, and ensure emergency responders understand the building’s override logic. Fail-secure should never be specified as a cheap substitute for proper egress hardware. We document mechanical override positions, UPS recommendations and the lock’s behavior at each power stage per SKU so building procedures match the installed reality.
Not literally for one device, because each electric strike or bolt is manufactured and listed in one failure state, but an opening can combine devices to cover both duties: common designs pair a fail-safe maglock on the egress path with a separate monitored or keyed control, or use electric strikes with selectable kits ordered for the required mode, plus mechanical overrides that work in every power state. Some high-security vestibules use different modes on each leaf (mantrap interlocks with their own controller logic). What matters is that the complete opening — every device, relay and override — is documented and tested against the fire strategy as one system. We review combined assemblies at the shop-drawing stage, list the failure state of each component, and confirm the tested behavior in every power and alarm scenario before hardware ships to site.
Provide the door schedule with egress classifications and the fire strategy. We supply listed strikes, maglocks and bolts in the correct modes, document power, UPS and override mechanics per opening, and support testing of free egress in every power state before handover.