North American doors run on 2-1/8 inch bored prep and deadbolts, graded under ANSI/BHMA, while wireless and fire-door rules shape the electronics.
North America — the United States and Canada — is a deadbolt market: most residential and light-commercial entrance doors are factory-bored 2-1/8 inch cylindrical openings with a separate deadbolt, defined by ANSI/BHMA A156 series preps and graded under A156.2, A156.13 and A156.25. Commercial openings add labeled fire doors assessed to UL 10C, ADA accessibility expectations, and wireless authorization under FCC rules in the US with corresponding Canadian radio and electrical requirements. Hotels remain a large offline RFID channel, and multifamily (MDU) projects mix common-area and unit-door credentials. Our factory supplies ANSI-prep deadbolts, cylindrical and mortise smart locks plus offline hotel and MDU families, and confirms grading evidence, radio documentation and fire-door logic for named SKUs in writing per RFQ. This page maps the door standards, electronic-access rules, channels and logistics realities our North American buyers actually plan around.
| Door standard | Residential and light-commercial doors use a 2-1/8 inch (roughly 54 mm) bored opening and a deadbolt; ANSI backsets are commonly 2-3/8 or 2-3/4 inch. |
| Lock grading | ANSI/BHMA A156.2 (cylindrical), A156.13 (mortise) and A156.25 (electronic) define grading and performance; grade evidence is tied to the exact listed SKU. |
| Fire doors | Commercial fire-rated openings commonly reference UL 10C; the certified hardware schedule must be preserved and egress stays mechanical. |
| Wireless | Radio modules follow US FCC authorization requirements; Canada applies its own radio and electrical market-access rules, confirmed per SKU in writing. |
| Accessibility | ADA expectations affect operable hardware, mounting height and access paths in commercial and multifamily specifications. |
| Channels | Offline RFID hotels, MDU multifamily portfolios, retail shelf programs and wholesale distribution each need different packaging and support. |
| Supply terms | MOQ, pricing, warranty terms and lead times are confirmed per RFQ; compliance documentation is provided for named SKUs only. |
Buyers get faster, safer quotations by declaring the door prep, required ANSI/BHMA grade, fire-door status, wireless region, channel and documentation expectations up front.
| RFQ element | Why it matters | What we return |
|---|---|---|
| Door prep | Bored 2-1/8 inch plus deadbolt, mortise or storefront prep changes the entire lock family | Model mapping matched to ANSI prep and backset |
| BHMA grade target | Grade 1, 2 and 3 correspond to different duty cycles and strength | Grade references for the exact listed SKUs |
| Fire-door openings | UL 10C-rated assemblies cannot accept field-modified hardware | Hardware selected inside the labeled schedule |
| Wireless region | FCC for the US; separate Canadian requirements apply | Radio documentation for named models, confirmed per RFQ |
| Sales channel | Retail packaging differs from project-bulk or hotel channel supply | Branding, packaging and manual configuration per channel |
| Service expectations | Distributors and hotel groups plan spare parts and support in advance | Written terms for spares, documentation and support per quotation |
Channel structure in North America is unusually distinct: retail shelf programs, hotel procurement, MDU operators and wholesalers rarely accept the same configuration or packaging.
| Segment | Typical opening | Supply approach |
|---|---|---|
| Retail brands | Residential bored deadbolt doors across the US and Canada | Retail-packaged ANSI deadbolts with branded manuals and cartons |
| Hotel groups | Guest-room and common doors, offline or online PMS projects | RFID or mobile-key families standardized floor by floor |
| MDU multifamily | Unit entrance doors plus lobby, amenity and service doors | Unit smart locks with common-area credential planning |
| Wholesale distribution | Mixed contractor demand across door types | Catalog SKUs, spares logic and graded commercial options |
| Project integrators | Commercial office and institutional openings | Mortise families matched to fire and access schedules |
| Canada buyers | Same bored-door culture, distinct radio and electrical rules | Documentation set confirmed for Canadian requirements per RFQ |
This is a typical scope list, not a customer case. The exact configuration, terms and documentation are confirmed per quotation.
| Component | Typical logic | Notes |
|---|---|---|
| ANSI-prep locks | Bored deadbolts, cylindrical levers and mortise families | Grading references provided for named SKUs |
| Hotel and MDU families | Offline RFID, mobile credential and common-door options | Topology confirmed against the property plan |
| Branding and packaging | Private-label cartons, manuals and retail-ready finishing | Artwork and configuration confirmed before production |
| Compliance packs | FCC-related and other access documentation per model | Issued per RFQ for selected SKUs only |
| Logistics and support | Ocean or air shipment, spare-parts planning, written terms | MOQ, lead time and warranty terms confirmed in writing |
There is no universal answer, but the grade follows the opening duty. Entrance and commercial doors are commonly specified toward Grade 1 or Grade 2 performance in the ANSI/BHMA A156 series, while lighter residential interiors can accept lower-duty products. The grade belongs to the tested lock assembly, not to the electronics or the brand label, so buyers should request the grading reference for the exact listed SKU rather than accept a family-level claim. We map door types to candidate families and confirm grading evidence per named model in writing; selecting and enforcing the grade for a given building remains the specifier’s responsibility.
UL 10C is a fire-door test used across much of US commercial construction, and a rated door must keep its labeled hardware configuration. Smart electronics are possible where the selected lock, frame, closer and releasing hardware are part of an assessed schedule, and immediate single-action mechanical egress is always preserved. We supply products against the documented door-and-hardware schedule and provide relevant material for the models involved; we do not field-approve modifications. The installing contractor and the authority having jurisdiction confirm the local acceptance path for each opening.
Wireless products sold in the United States sit under FCC authorization requirements, and Canada maintains its own radio and electrical market-access framework. We provide compliance documentation for the named SKUs included in each quotation and confirm in writing which models carry which paperwork; we do not make blanket catalog-wide certificates. Buyers building retail or project specifications should send the model list and destination country early so the document set can be checked before tooling or branding work begins. Importers remain responsible for placing the product on the market under the applicable rules.
Most North American residential doors are bored for a 2-1/8 inch cylindrical lock plus a separate deadbolt, with 2-3/8 or 2-3/4 inch backsets, whereas European doors are dominated by Euro-profile cylinders and mortise pockets. Interchangeability is therefore not a matter of adapters alone: the lock body, strike, tail and handing all differ. Importers sometimes request both catalogs for cross-border programs, and we keep the two prep standards as separate model lines rather than forcing one hardware family onto both door cultures.
Hotel programs usually standardize one offline RFID or mobile-capable family across guest floors, with encoder, credential and common-door logic agreed before rollout; larger projects may add PMS-oriented integration. MDU portfolios combine unit-door locks with lobby, package and amenity doors and often want audit and staff-credential workflows. Both channels buy against a property schedule rather than a catalog page, and both care about spare-parts availability and consistent firmware. We confirm topology, documentation and commercial terms per RFQ without quoting customer names or project numbers.
Send your channel mix, door prep list and target standards — receive a model map with documentation and commercial terms confirmed per RFQ.
Request a Quote (RFQ)Project configurationsLast updated: October 31, 2026 · Reviewed by the Smart Lock Factory editorial team