Double leaves need sequence as much as security. Flush bolts, a coordinator and strike alignment decide whether the opening closes and latches every time.
A double-leaf door is two leaves with different jobs. The active leaf carries the lock and daily traffic; the passive leaf is held at top and bottom by automatic flush bolts and released only for equipment moves. Smart access on a double door normally controls the active leaf only, because controlling both halves doubles the wiring and failure points while adding little security — the passive leaf cannot open while its bolts are thrown. The real engineering is coordination: a coordinator arm ensures the passive leaf closes before the active leaf strikes, and misadjusted flush bolts are a leading cause of nuisance alarms. This guide covers the hardware stack, one-leaf versus two-leaf control and the commissioning checks.
| Leaf roles | Active leaf carries the lock; passive leaf uses top/bottom automatic flush bolts and opens for wide loads only. |
| Coordinator | A door coordinator sequences closure so the passive leaf seats before the active leaf latches. |
| Smart coverage | Most projects credential the active leaf; dual-leaf control is chosen only for specific symmetry or access needs. |
| Strike alignment | The active leaf strike must meet the frame with both leaves closed; adjustment follows coordinator setting. |
| Fire doors | Labeled double fire doors require listed coordinators and flush bolts; free egress applies to both leaves. |
| Astragal options | Overlapping or meeting stiles influence escutcheon choice and weather sealing. |
| Commissioning | Both leaves are tested for sequence, flush-bolt throw and single-action egress before handover. |
Active-leaf control with automatic flush bolts is the default; both-leaf smart locks appear where policy or symmetry demands independent credential entry per leaf.
| Question | One-leaf control | Two-leaf control |
|---|---|---|
| Daily entry | All traffic through active leaf | Either leaf opens on credential |
| Passive security | Automatic flush bolts, released manually | Motorized flush bolts with release logic |
| Cost and wiring | One lock, one reader, standard frame prep | Two locks, flush-bolt automation, more checks |
| Fire coordination | Standard listed coordinator | Coordinator plus synchronized release |
| Wide-load access | Release bolts with key/tool for moves | Release via credential with logging if required |
| Typical use | Offices, retail, storerooms | Ceremonial entrances, galleries, special logistics |
A smart lock cannot fix a mis-coordinated pair: coordinator, flush bolts and strike are commissioned as one mechanism before electronics are blamed.
| Opening | Typical door | Lock approach |
|---|---|---|
| Office double entrance | Two aluminum/steel leaves, daily one-leaf use | Smart active leaf + auto flush bolts |
| Fire stair double door | Labeled pair with closers | Listed coordinator, exit devices both leaves |
| Retail double front | Glass leaves with center meeting stiles | Reader on active leaf; passive bolted nightly |
| Ballroom / hall doors | Both leaves opened for events | Motorized flush bolts with controlled release |
| Warehouse double leaf | Wide loads, often held open in shifts | Smart active leaf; mechanical coordinator guard |
| Residential double gate | Timber or metal pair | Smart lock on main leaf, drop bolts on other |
This example illustrates a typical configuration, not a specific customer project. Leaf role and fire schedule drive the list.
| Component | Typical logic | Notes |
|---|---|---|
| Active-leaf smart lock | One credential lock matched to door material | Reader height coordinated per leaf |
| Automatic flush bolts | Top and bottom bolts on passive leaf | Listed versions on fire doors |
| Coordinator | Surface or concealed coordinator arm | Adjusted at commissioning |
| Exit hardware | Panic devices where required per leaf | Free egress both directions as scheduled |
| Commissioning test | Sequence and latch verification per opening | Recorded in handover documentation |
Usually no. With automatic flush bolts holding the passive leaf at top and bottom, that leaf is already secure and cannot be forced open independently; every ordinary visitor enters through the active leaf. Adding a second credential lock means another reader, another power source or battery schedule, another strike to align, and synchronized release logic. Both leaves are independently controlled where operations genuinely need entry through either leaf — ceremonial entrances, event spaces with motorized flush bolts, or logistics doors with logged wide-load release. For standard offices and retail doors, one smart lock plus quality coordinator hardware is the documented recommendation.
A coordinator is a mechanical arm or rail mounted at the head of a double-leaf opening that holds the active leaf until the passive leaf has fully closed, preventing a situation where the active leaf slams against an unbolted passive leaf and fails to latch. On fire doors this sequence is a code-relevant feature because an unlatched pair will not hold a fire compartment. Coordinators are adjusted after closers and flush bolts, and they are tested by releasing both leaves together from full open. Persistent mis-latching, worn carpet contact or people propping the passive leaf are addressed mechanically — a smarter lock cannot replace a missing or maladjusted coordinator.
A rod inside the passive leaf connects top and bottom bolts to a trigger at the meeting stile. When the passive leaf is pushed closed, the trigger contacts the strike on the active leaf or frame and the bolts spring into the frame keepers automatically; opening the active leaf and depressing the trigger (or turning a labeled release) retracts the bolts so the passive leaf can be opened for wide loads. Fire-rated versions are listed and latch without manual lifting. Motorized versions add credential-controlled release and logging for event spaces. Bolts and keepers need periodic lubrication and adjustment as buildings settle.
Yes: egress rules apply to both leaves regardless of credential state. The active leaf opens with its standard exit device or handle from inside, and exit hardware on the passive leaf retracts the flush bolts mechanically so the pair can be pushed open for full-width evacuation. On fire-labeled assemblies the coordinator, closers and exit devices are all listed parts of the rated system, and electrified components default to their defined safe state on alarm. Commissioning includes single-action egress tests from each leaf and an alarm-release test; the results are handed over with the door schedule.
Temperature, wear and coordinator drift are the usual causes. Building frames move overnight, closers lose oil and closing force, flush-bolt keepers shift after settling, and the active leaf then meets the passive leaf instead of the strike. HVAC schedules and warped astragals add binding. The diagnostic sequence starts with closing both leaves slowly by hand to see where contact happens, then checking coordinator timing, flush-bolt extension, closer sweep speed and strike position. Smart lock logs showing “closed but unsecured” events identify the timing; correction is mechanical adjustment, not a lock replacement, and belongs in preventive maintenance.
Send the double-door schedule with fire labels and leaf roles — receive a hardware and coordinator list with commissioning terms.