IK codes describe impact energy in joules. They help choose vandal-resistant hardware for public spaces, but a pendulum test is not a forced-entry or prying rating.
The IK code, defined by IEC 62262 (Europe: EN 62262), rates the degree of protection an enclosure provides against external mechanical impacts. The scale runs from IK00 (no protection) through IK01 (0.14 joule) to IK10 (20 joules), delivered by standardized pendulum hammers, spring hammers or free hammers of defined masses and drop heights — IK10, for example, corresponds to a 5 kg mass from 400 mm. Each strike lands on defined points of the enclosure, which must remain safe and functional afterward. For smart locks, IK codes matter on exposed public hardware: gate keypads, parking entrances, rear-of-store doors and transit installations. Specifiers should keep two boundaries in mind: IK measures blunt impact, not lever attacks, drilling or sustained vandalism (those belong to EN 1627 or ANSI/BHMA security tests), and the enclosure may survive while the door or reader behind it does not. This guide explains the scale, selection logic and evidence our factory provides for named SKUs per quotation.
| Standard | IEC 62262 (EN 62262) defines impact-protection codes for electrical enclosures, complementary to the IEC 60529 IP system. |
| Scale | IK00 is unprotected; IK01 to IK05 cover 0.14 to 0.7 joule; IK06 to IK10 run from 1 to 20 joules. |
| IK10 meaning | 20 joules, delivered for example by a 5 kg pendulum falling through 400 mm, striking the enclosure at defined points. |
| Test method | Standardized pendulum, spring or free hammers strike representative points; the enclosure must remain safe and functional afterward. |
| Where it matters | Unsupervised outdoor keypads, gate readers, parking and transit hardware, school and nightlife corridors face the highest casual-impact risk. |
| What it excludes | Prying, levering, drilling, tool attacks and repeated sustained beating; forced-entry resistance uses EN 1627 or ANSI/BHMA A156.30-style evidence. |
| Evidence | An IEC 62262 test report naming the SKU and code, with the tested mounting and impact points; informal claims such as “vandal proof” are not ratings. |
Casual knocks and thrown objects define most real exposure, which pushes unsupervised exterior hardware toward IK08–IK10. Deliberate forced entry is a separate engineering problem entirely.
| Environment | Typical level | Typical threat |
|---|---|---|
| Indoor office, hotel floor | IK03 to IK06 | Bags and accidental contact. |
| Shared apartment corridors | IK06 to IK08 | Moving boxes, bicycles, rough handling. |
| Retail back and service doors | IK08 | Deliveries, trolleys and cleaning equipment. |
| Unsupervised exterior gates | IK09 or IK10 | Kicks, thrown objects and casual vandalism. |
| Transit and parking sites | IK10 plus mounting substrate design | High-energy strikes and attempted damage. |
| Nightlife and school zones | IK10 with tamper alarms and surveillance | Sustained abuse beyond what a code alone solves. |
The rated enclosure performs only as well as its mount and the door behind it. High-IK escutcheons are specified together with substrate, fixings and monitoring rather than as a label in isolation.
| Opening | Typical door | Lock approach |
|---|---|---|
| Mounting plate | Rigid steel backing and anti-rotation fixings | Flex behind the panel absorbs nothing at IK10. |
| Fasteners | Security screws or concealed bolts | Exposed standard screws invite deliberate removal. |
| Reader windows | Impact-rated lens material over the sensor | A cracked window disables even an intact body. |
| Cable routing | Harness protected inside the door or frame | Impact must not expose or shear wiring. |
| Tamper signaling | Switch or accelerometer alert to the access platform | Turns an impact event into a dispatched response. |
| Environmental pairing | IK plus IP plus corrosion evidence | Public sites face all three simultaneously. |
For named public-space SKUs our factory provides the pack below per quotation, separating genuine enclosure-impact evidence from marketing language and from the different question of attack resistance.
| Component | Typical logic | Notes |
|---|---|---|
| IEC 62262 test report | States the IK code, energy and impact points for the SKU. | Core evidence for the claim. |
| Mounting specification | Plate, screws and substrate required to reproduce the test. | Critical because field mounting changes results. |
| Materials description | Lens, cover and housing materials and thickness. | Supports durability expectations under UV and cold. |
| Tamper-event description | How the electronics report impacts and cover removal. | Links hardware to the monitoring platform. |
| Scope clarification | Written note that IK is impact, not forced-entry resistance. | Helps specifiers add EN 1627 where needed. |
Under IEC 62262, IK08 is 5 joules, IK09 is 10 joules and IK10 is 20 joules. For scale, the IK10 pendulum is a 5 kg mass dropped through 400 millimeters at the striking point, while mid-scale codes use lighter hammers or shorter drops. The strikes are applied to representative points on the enclosure — faces, corners and weak points defined in the method — and afterwards the housing must remain safe, with no dangerous access to live parts and no loss of required function. For an unsupervised gate keypad, IK10 means it should absorb a strong kick or thrown object without exposing electronics, which is why it dominates exterior public-access specs.
No, and specifiers should not read it that way. IK tests simulate accidental or casual impact with defined masses; a deliberate attacker with a screwdriver, crowbar, drill or hammer is covered by security standards — European burglary-resistant doorsets under EN 1627 (RC1–RC6 classes), high-security cylinders under EN 1303 or ANSI/BHMA A156.30, and the lock security digits of EN 12209/EN 14846. An IK10 escutcheon can still be levered off a weak substrate or bypassed through the cylinder. High-risk doors therefore combine IK10 hardware with an RC-rated assembly, high-security cylinder, security fixings and, increasingly, tamper alarms.
The enclosure is mounted on a rigid support as defined in IEC 62262, and a pendulum hammer, spring hammer or free-falling mass of the mass and drop height corresponding to the code is released against specified impact points: flat faces, corners, operating elements and weak areas receive the strikes, with the number and distribution set by the standard. After the sequence the enclosure is inspected for access to hazardous parts, loss of ingress protection beyond allowed limits and functional damage. Because mounting stiffness affects results, a device tested on a steel jig can behave differently on a thin sheet-metal door, which is why the report should be read together with the required mounting specification rather than treated as a standalone sticker.
Yes, and public-space hardware usually needs both; the codes are complementary and defined by sister standards, IEC 60529 for dust and water and IEC 62262 for impact. A typical exterior gate keypad might be specified IP66 IK10: dust-tight and jet-resistant, plus 20-joule impact survival. Each code needs its own test report, and the combined specification should also name the corrosion expectation, because chlorides and cleaning chemicals degrade housings that neither test addresses. In practice the mount, cable gland and cover design that seal water are often the same elements that absorb impact, so well-engineered outdoor platforms tend to achieve the pair together, but the evidence remains separate.
Occasionally, but it is usually wasted cost. IK10 construction means thick housings, rigid mounts and tougher reader windows, which add price, weight and sometimes battery-access friction. Indoor corridors, offices and hotel floors experience bag bumps and accidental contact well below IK06–IK08 territory, and the building’s access control, cameras and staff presence handle deliberate damage better than enclosure mass. The right level follows the site threat model: supervised interiors at moderate IK levels, unsupervised exteriors at IK10, and locations with recorded attacks at IK10 plus monitoring and attack-rated door assemblies. We help map the code to the actual incident profile rather than defaulting every project to the highest number.
Share the location and incident history. We quote IK-rated SKUs with the matching mounting specification, IEC 62262 report and tamper-signaling options for unsupervised openings.
Request Spec Sheet + QuoteCertifications overviewLast updated: October 31, 2026 · Reviewed by the Smart Lock Factory editorial team