In Europe the door, frame, seals, hinges and lock are tested together under EN 1634. Classification lives with the assembly, and hardware substitution breaks the chain.
EN 1634 is the European family of fire and smoke resistance test methods for doorsets, shutters and openable windows. EN 1634-1 covers fire resistance, challenging the complete assembly against a standard furnace curve and judging integrity (E — the door prevents flames and hot gases passing) and, where required, insulation (I — the unexposed face stays within temperature limits), with results classified under EN 13501-2 as classes such as E 30, EI 30 or EI 60, plus EW for reduced radiation. EN 1634-3 covers smoke control at ambient and medium temperatures, expressed as S_a (ambient) and S_m (medium-temperature) leakage classes that depend critically on continuous seals and controlled gaps. As under UL 10C, the lock, closer, hinges and seals are part of the tested assembly; a component declared fire-suitable under EN 12209 or EN 14846 is not a fire door on its own. This guide explains the classes, the certificate structure and how our factory documents locks intended for European rated doorsets per quotation.
| Parts | EN 1634-1 covers fire resistance; EN 1634-3 covers smoke leakage at ambient (S_a) and elevated (S_m) temperatures. |
| Integrity E | The doorset prevents flames and hot gases passing for the rated duration, such as E 30 or E 60 minutes. |
| Insulation I | Added to E (EI) where the unexposed face must stay below temperature limits; EW limits radiant heat instead. |
| Classification | Results are classified under EN 13501-2 and EN 13501-3 into classes that appear on the doorset certificate and label. |
| Assembly scope | Leaf, frame, seals, hinges, locks, closers, glazing and fixings are tested as one configuration — nothing swaps without evidence. |
| Hardware components | Locks used must carry the fire-suitability digit under EN 12209 or EN 14846 and be named in the doorset test report. |
| Evidence | The door manufacturer holds the assembly certificate; lock suppliers provide component declarations and EXAP or extended-application references. |
The building designer sets the class from the compartmentation strategy; the lock buyer’s job is to stay inside the listed hardware set for that class, not to negotiate substitutes.
| Class | Performance it describes | Typical location |
|---|---|---|
| E (integrity) | Stops flames and hot gases for the rated minutes. | External and separating walls where insulation is set elsewhere. |
| EI (integrity + insulation) | Also limits temperature rise on the cold face. | Corridor and compartment doors near combustible materials. |
| EW (radiation control) | Limits radiant heat flux through the leaf. | Some separating and escape-route assemblies. |
| S_a (ambient smoke) | Low leakage at ambient temperature. | Smoke partitions protecting escape routes. |
| S_m (medium temp smoke) | Leakage control at elevated temperatures. | Doors expected to see early fire heat while containing smoke. |
| Combined classes | Examples: EI₂ 60 S_a, E 30 S200 C5 in full notation. | Exact notation is copied from the classification report. |
European certified doorsets carry a classification report naming every permitted component. When smart locks are retrofitted, the door manufacturer or an extended application (EXAP) rule must cover the substitution.
| Opening | Typical door | Lock approach |
|---|---|---|
| Hotel corridor doors | EI-rated doorsets with electronic lock listed in the report | The smart lock must be the tested or EXAP-covered model. |
| Stair and lobby doors | E or EI with self-closing and smoke seals | Holders release on alarm; free egress preserved. |
| Hospital compartment doors | EI plus smoke class with clinical hardware | Lock functions cannot compromise closing force. |
| Smoke partitions | S_a/S_m doors where gap control is decisive | Only listed strikes; latches must pull the leaf fully closed. |
| Industrial fire walls | High-minute E or EI steel doorsets | Heavy-duty listed locks and closer coordination. |
| Existing door retrofits | Require EXAP or door-maker written approval | Unlisted electronic locks void the classification. |
Our factory supplies the component-side evidence below for named SKUs per quotation. The assembly certificate remains with the doorset manufacturer, and our documents are written to slot into that technical file.
| Component | Typical logic | Notes |
|---|---|---|
| Component declaration | EN 12209 or EN 14846 classification with fire-suitability digit 1. | Proves the lock is eligible for fire-door use. |
| Doorset test references | Examples of EN 1634 reports that include the lock family. | Helps the door maker extend coverage to the project. |
| EXAP guidance note | When extended application rules allow substitution. | Reviewed case by case with the test sponsor. |
| Mounting and spindle data | Preparation, spindles and follower behavior affecting latching. | Critical to maintaining smoke-gap performance. |
| Scope statement letter | Written confirmation of which quoted SKUs target rated doors. | Prevents unlisted models entering the order. |
Integrity (E) means the doorset prevents flame and hot gas penetration and keeps mechanical action for the rated time — 30, 60, 90 minutes and so on. Insulation (I) adds a limit on temperature rise at the unexposed face, protecting people and combustible materials on the cold side; combined, the class reads EI 30 or EI 60. A third letter, W, denotes radiation control (EW), limiting radiant heat flux rather than average surface temperature. The fire-safety engineer assigns the class from the compartmentation design, and the doorset certificate states exactly which letter combination and duration were achieved — buyers copy the notation verbatim rather than ordering “a 60-minute door” loosely.
Smoke doors are tested under EN 1634-3 rather than burned in a furnace. S_a measures air leakage at ambient temperature, around 20 °C, while S_m repeats the leakage test at elevated temperatures, simulating early fire heat. A door classified S_m also satisfies the S_a conditions. Leakage depends on the whole assembly: continuous smoke seals, controlled perimeter gaps, a latch that pulls the leaf firmly shut and a correctly adjusted closer. Gapping the door, dropping the seal or fitting an unlisted strike destroys the smoke class even if the door would still pass a fire test, which is why smoke-door maintenance focuses on gaps and closure.
Only through a formal route. The doorset certificate lists the permitted lock models; a different electronic lock requires either an extended application (EXAP) standard or report that explicitly allows the substitution class, or written approval from the doorset test sponsor or manufacturer. Simply fitting a similarly sized electronic escutcheon, even one with fire-suitability digit 1 under EN 14846, is not enough because spindle torque, latching force and handle projection all affect the tested behavior. For large retrofit programs the cleanest path is selecting the smart lock early with the door maker so it is written into the classification before doors are ordered.
The doorset manufacturer or the party that sponsored the test holds the classification report and the corresponding CE Declaration of Performance under EN 16034 for fire and smoke doorsets. Lock and hardware manufacturers hold component evidence — EN 12209 or EN 14846 classifications with fire suitability and their own reference doorset reports — but they cannot issue a fire rating for an assembled door they did not test. On a project, the technical file combines the door certificate, the component declarations and the installation and maintenance instructions. Our role is to supply precise, SKU-specific component evidence that makes the door manufacturer’s file complete.
Yes. Electromagnetic hold-open devices are part of the controlled assembly: they must be listed for the doorset, installed in the permitted positions, and wired to release on fire alarm activation so the door closes and latches automatically. A permanently wedged or propped fire door fails its purpose regardless of its certificate. Linked door retainers and free-swing closers follow the same logic — listed hardware, correct power supply, alarm integration and documented commissioning. Our electrified lock quotations identify where holders are involved and provide the component data the controls contractor needs, while final acceptance remains with the fire strategy and the authority having jurisdiction.
Send the doorset class and manufacturer. We confirm which named SKUs have fire-suitability declarations and reference reports, and provide the component evidence package for the technical file.