
A 100-door warehouse is mostly about rhythm: shift changes, dock traffic and zone control have to work faster than a key cabinet ever could.
This page is a representative typical configuration for a distribution warehouse with about 100 controlled openings, not a delivered project for a named operator. It shows how logistics planners usually combine person doors, aisle gates, dock positions and restricted stores under one credential system driven by shift schedules. Warehouse staff receive PIN codes or cards tied to their shift and zone, forklift and reach-truck drivers get credentials for the aisles they actually work, and visiting drivers receive narrow time windows for a specific dock rather than general floor access. Because doors face weather, dust and constant traffic, outdoor-rated hardware and protected readers matter more than aesthetics, and battery service must be scheduled around operations. Restricted areas such as bonded stores, chemical cabinets and dispatch offices carry access groups with audit review. Quantities, gateway ratios and specifications are planning estimates only; exact quantities and specifications are confirmed per project quotation.
| Site profile | A representative distribution or fulfillment warehouse of roughly 100 controlled openings, operating multiple shifts with dock traffic. |
| Openings in scope | Planning estimate of about 100 openings covering person doors, aisle gates, dock positions, offices and restricted stores. |
| Credential architecture | Shift-linked PIN codes and cards, zone-scoped forklift credentials, time-boxed driver codes and role-based office access. |
| Software/integration | Central platform with shift rules, zone groups, audit retrieval and optional warehouse-system linkage confirmed per project. |
| Network/power | Outdoor-rated readers at docks, battery locks on remote gates, gateways zoned by measured coverage inside steel shelving. |
| Compliance evidence | Environmental, radio and electrical evidence for named SKUs are provided per RFQ; egress follows local fire code. |
| Commercial terms | Current MOQ policy, sample terms and lead time are confirmed in writing per quotation; certificates and test reports for named SKUs are provided per RFQ. |
Shifts and docks set the real door logic. Person doors should open for the people scheduled that hour, aisle gates for the zones those people work, and dock positions only for the trailer being served. Once access follows the operating rhythm instead of a static key list, audits and exceptions become meaningful.
| Opening group | Typical choice | Scale reasoning at 100 doors |
|---|---|---|
| Staff entrances | Keypad lock with shift-based schedules | The main turnover point where every shift change is validated and logged. |
| Aisle gates and cages | Keypad or reader gate lock in a zone group | Limits pickers and trucks to assigned aisles without reissuing credentials. |
| Dock and overhead doors | Outdoor-rated shutter or overhead-door lock | Loading runs all weather, so hardware must survive daily cycling and rain. |
| Dispatch and office doors | Keypad lock with role groups | Clerical and dispatch access is separated from floor credentials. |
| Bonded or chemical stores | Dual-authorization reader lock | Controlled goods need two-person rules and exportable audit records. |
| Driver waiting and welfare points | Time-boxed PIN codes | Visiting drivers receive narrow windows that expire automatically. |
| Evidence level | What this page states |
|---|---|
| L1 authorized named case | A named warehouse or 3PL operator case requires written authorization. None is published without NDA, so no such case is claimed here. |
| L2 public-reference case | Public references to comparable distribution sites may be cited where independently published, without confirming we supplied them. |
| L3 NDA photo or record case | Photos and delivery records for similar 100-door sites can be shared with qualified buyers under mutual NDA per RFQ. |
| L4 genericized record | Anonymized records keep opening counts, shift logic and zone groups while removing operator and site identity. |
| L5 representative typical configuration | What is published here is an L5 typical configuration: an illustrative 100-door logistics plan for budgeting and RFQ discussion, not a statement of a delivered project. Higher levels are provided to qualified buyers under NDA per RFQ. |
This is a planning bill of materials for budgeting, not a quotation. Opening counts come from the door schedule, while gateway and reader quantities follow the measured coverage and dock layout confirmed per project quotation.
| Component | Quantity logic | Notes |
|---|---|---|
| Component | Typical quantity logic | Notes |
| Keypad locks | Around one per person door, counted from the opening schedule | Shift and zone logic is configured centrally, not on the device. |
| Aisle gate locks | One per controlled gate or cage | Gate hardware must tolerate daily impact and dust. |
| Dock door locks | One per controlled dock or overhead door | Outdoor-rated assemblies specified for the fitted opening. |
| Readers and controllers | One per restricted store or dual-authorization door | Hardwired where power and code design allow. |
| Gateways | One per coverage zone inside steel shelving | Steel racking creates dead spots; coverage is measured. |
| Spare locks and batteries | A pool sized to shift risk and service distance | Service visits are scheduled outside peak dispatch. |
Re-check the items below when your project is smaller or larger than the representative scale on this page.
| Scale factor | How the configuration changes | What to verify |
|---|---|---|
| Scale factor | Impact on configuration | Planning note |
| Shift patterns | Static keys fail once shifts rotate faster than reissue cycles | Model schedules before choosing lock models. |
| Dock volume | Dock access becomes a traffic problem, not a security problem | Time-box driver credentials to the trailer being served. |
| Zone complexity | Aisle control multiplies as pick faces expand | Keep zone groups small and auditable. |
| Outdoor exposure | Dust, rain and impact wear out indoor hardware quickly | Require verified ratings for the whole assembly. |
| Staff turnover | Credential churn is constant in logistics | Automate expiry and revocation from the start. |
| Audit expectations | Customers and insurers ask for opening records | Agree retention and export formats early. |
Send your opening schedule, shift pattern and dock layout. We confirm lock families, zone grouping, reader and gateway counts and audit integration; current MOQ policy, sample terms and lead time are confirmed in writing per quotation, and certificates and test reports for named SKUs are provided per RFQ.
Request Similar ConfigurationProject configurationsLast updated: November 1, 2026 · Reviewed by the Smart Lock Factory editorial team