RFID hotel card lock SLK-760 supports password and RFID access with standalone locks, PC encoder management, onboard access logs, and custom finishes for hotel projects. Request a project quotation.

SLK-760 Combines RFID Access, Password Entry and Standalone Management

The SLK-760 is a split-style RFID hotel card lock that provides password and RFID access for hotels, residential projects, and other lock installations managed through PC encoder software. It operates as a standalone lock without in-room networking, which supports retrofit planning where door wiring for networked access controls is not required.

  • RFID card access and passcode entry are standard, so staff can use programmed guest credentials while authorized users can enter a password without a physical card.
  • The standalone lock connects to a PC-linked card encoder for management, so guest card issuance, room permissions, validity windows, and unlock records can be handled without an in-room network.
  • Onboard access logs record lock activity, so managers can review unlock records through the supported PC encoder management workflow rather than relying only on physical key usage.
Access methods
Passcode / keypad access and RFID / IC card access
Network architecture
Standalone lock with PC-linked card encoder; no in-room network required
Management functions
Guest card issuance, floor and room permissions, check-in validity windows, and unlock records
Product style
Split-style RFID hotel card lock
Project documentation
Dimension drawings, installation guide, and full datasheet available on request
OEM and ODM
Custom logo, finish, packaging, manuals, and product configuration

What makes the SLK-760 a project-grade hotel lock

SLK-760 Standalone access without in-room network wiring

01Standalone access without in-room network wiring

The SLK-760 operates as a standalone lock managed through a PC-linked card encoder, so no in-room network is required. This can reduce network installation work and allows projects to add electronic card access where network cabling is impractical.

02Two supported access methods for different operational needs

RFID card access and passcode entry are both standard, so the lock can support issued guest credentials and password-based access. Staff can select the method that matches the access situation instead of issuing a physical key for every authorization.

SLK-760 Two supported access methods for different operational needs
SLK-760 PC encoder workflow for room-level administration

03PC encoder workflow for room-level administration

The PC encoder and hotel lock management software handle guest card issuance, floor and room permissions, and check-in validity windows. These functions give property teams a defined workflow for setting guest access before arrival and controlling it during the stay.

04Onboard records support access administration

The lock stores unlock records that can be reviewed through the supported management setup. This gives operators a record of room activity for administration rather than leaving access history outside the lock-management workflow.

SLK-760 Onboard records support access administration

How the SLK-760 works

The SLK-760 manages programmed guest access through a PC encoder and standalone locks, without requiring an in-room network.

  1. Configure the access system. Install the hotel lock management software and connect the PC encoder to the administration computer. The encoder becomes the interface for programming guest credentials and lock access data.
  2. Set room permissions. Assign floor and room permissions and define the check-in validity window for each issued credential. This gives the lock a defined guest-access period.
  3. Issue the guest card. Create and write the RFID guest card through the PC encoder workflow. The guest can then use the issued RFID card at the assigned lock.
  4. Use the selected access method. An authorized user can present an RFID card or enter the assigned passcode. The lock applies the programmed room access and records the unlock event in its onboard access log.
  5. Review unlock records. Retrieve and review the stored unlock records through the supported PC encoder management workflow. Administrators can use the activity record for access administration.

System & compatibility

The SLK-760 is a standalone, PC-linked RFID hotel lock system with supported card and password access but no specified in-room network or mobile-app connection.

RFID / IC card accessStandard
Passcode / keypad accessStandard
Fingerprint access—
3D face recognition—
Finger vein recognition—
Mobile app access—
Mechanical override key—
Remote control / fob—
In-room networkNot required for the specified standalone architecture
Management platformHotel lock management software with PC encoder and guest cards

Review the Specification tab for the SLK-760 project configuration, and request dimension drawings, the installation guide, and the full datasheet for exact technical confirmation.

Compare with related models

A fact-by-fact comparison with other SLK models in the same product family, so you can choose the closest match for the door and project at hand.

SpecificationThis modelSLK-308SLK-309SLK-502SLK-236
Access methodspasscode, RFID/IC cardpasscode, RFID/IC cardpasscode, RFID/IC cardpasscode, RFID/IC cardpasscode, RFID/IC card, mechanical key
Smart platformHotel lock management software (PC encoder + guest cards)Hotel lock management software (PC encoder + guest cards)Hotel lock management software (PC encoder + guest cards)Hotel lock management software (PC encoder + guest cards)Hotel lock management software (PC); TTLock on keypad versions
Network modeStandalone lock; PC-linked card encoder (no in-room network required)Standalone lock; PC-linked card encoder (no in-room network required)Standalone lock; PC-linked card encoder (no in-room network required)Standalone lock; PC-linked card encoder (no in-room network required)—

Figures are taken from each model’s own specification sheet. Confirm door preparation, credentials and project options before approval.

Where the SLK-760 is installed

SLK-760 is installed in hotel guest rooms with RFID card and passcode access, using a standalone lock and PC-linked encoder that requires no in-room network.

SLK-760 - Hotels & resorts
Hotels & resorts
Front-desk staff can issue guest cards with floor, room, and check-in validity permissions through the PC encoder and hotel lock management software.
SLK-760 - Serviced apartments & short-stay
Serviced apartments & short-stay
The standalone SLK-760 supports reissued RFID cards for changing residents without requiring an in-room network, while preserving unlock records.
SLK-760 - Renovation & retrofit projects
Renovation & retrofit projects
For retrofit projects, SLK-760 requires no room wiring and provides dimension drawings, an installation guide, and a full datasheet on request.

Related resources for your project

Configure the SLK-760 for your project
Send door dimensions, quantities and finish — we return a fitted configuration, packing and a project quotation.
Request a quote
Request the catalog
Access Methods
Fingerprint Access—
Passcode / Keypad AccessStandard
RFID / IC Card AccessStandard
3D Face Recognition—
Finger Vein Recognition—
Mobile App Access—
Mechanical Override Key—
Remote Control / Fob—
Smart Platform & Connectivity
Smart Platform / Management Hotel lock management software (PC encoder + guest cards)
Network Mode Standalone lock; PC-linked card encoder (no in-room network required)
Management Functions Guest card issuance, floor/room permissions, check-in validity windows, unlock records
Mechanical
Product Style RFID Hotel Card Lock
Documentation & OEM Service
Documentation Dimension drawings, installation guide and full datasheet available on request
OEM / ODM Custom logo, finish, packaging, manuals and product configuration for distributor and project orders

The SLK-760 differs from the SLK-236 on smart platform: it is built around Hotel lock management software (PC encoder + guest cards) rather than Hotel lock management software (PC), TTLock on keypad versions. The two models share one family but diverge on smart platform; pick the SLK-760 for hotel lock management software (pc encoder + guest cards), or specify the SLK-236 rather than the SLK-760 for hotel lock management software (pc), ttlock on keypad versions.

The SLK-760 is managed through Hotel lock management software (PC encoder + guest cards), with functions covering guest card issuance, floor/room permissions, check-in validity windows, unlock records. Standalone card locks issue credentials at the front-desk encoder and do not require in-room networking; networked versions exchange data with the property platform. The property should state its current locking platform and number of floors or rooms; integration method and any encoder or gateway are then confirmed for the site.

The SLK-760 is supplied with passcode and RFID/IC card access. Every listed method is taken from the model’s own specification sheet rather than assumed for the family. Different doors on the same site can be configured for different methods, so map users to openings before finalising the model list.

Guest credentials are written to RFID/IC cards at a front-desk encoder working with Hotel lock management software (PC encoder + guest cards); the lock itself reads the card offline, so no wiring to each door is needed for a standalone system. Before approval, specify how many front-desk encoders and how much card stock are required, and include operator training in the handover.

The SLK-760 is an RFID Hotel Card Lock. Unlocking is by passcode and RFID/IC card. The classification and credential set above are taken from the model specification sheet, not inferred from similar-looking locks.

A lost card is deactivated at the management encoder and a replacement card is issued to the guest, so the lost credential no longer opens the SLK-760. The property confirms the authorisation level needed to void a card, and staff are trained on the encoder steps during handover.

The factory supports custom logo, finish, packaging, manuals and product configuration for distributor and project orders for the SLK-760. Branding artwork, finish approvals, packaging layout and any model-configuration changes should be agreed and supplied before production so the branded items match the approved samples.

The dimension drawings, installation guide and full datasheet are available on request. Certification for the destination market, warranty length and spare-parts scope are model-specific and confirmed per project; OEM terms (custom logo, finish, packaging, manuals and product configuration for distributor and project orders) can be included. Spare-parts scope and support period are settled alongside the document package so after-sales responsibilities are clear at handover.