SLK-230 and the Door It Has to Live In: Fit, Clearance and Retrofit
Buying a hotel lock is a product decision. Buying one for a door that already exists is an engineering decision, and the difference shows in the way the record for the model is written. These slk 230 door fit notes start from that record: the SLK-230 is logged as an RFID hotel electronic card lock in 304 stainless steel with a silver finish, driven by 4 × AA alkaline batteries, with a mechanical override, a low-battery alert, and a standalone arrangement in which a PC-linked card encoder feeds a standalone lock with no in-room network required.
Direct answer. In brief, this article covers slk 230 door fit notes from slk 230 door fit notes to slk-230. It states what to confirm about slk 230 door fit notes on the dated product page where a figure is involved. A slk 230 door fit notes is a component-level look at how the technology behaves. slk 230 door fit notes is where the limits sit. slk 230 door fit notes is verified on the dated product page.
- Check the capability — confirm on the dated product page for the specific SKU behind slk 230 door fit notes
- Check the limit — record where the technology in slk-230 stops working
- Check the fallback — name the mechanical path that remains if slk 230 door fit notes fails
- For slk 230 door fit notes, the order below is fixed and slk 230 is the reference point.
That description is complete about behaviour and empty about geometry. The door-fit group in the catalogue row is a dash, and so are the capacity and versions group and the environment group. No thickness band, no panel dimensions, no case pocket family, no backset, no reader position, no projection into the reveal — none of it is published in the catalogue entry, and every value an installer will cut to arrives instead on the dimension drawings, the installation guide and the dated product page for the specific SKU.
What follows is written for the person who has to release an order and then live with it. It treats the SLK-230 as what the catalogue says it is: a card-driven hotel lock for guest-room leaves, in stainless steel, running on cells, with no in-room network, and with a sibling record — the SLK-230-F, a front-mount version — whose fitting method is settled before a single hole is drilled. It covers the readings that sort a door population into families, the clearance argument between leaf, frame and closer, the battery route a corridor has to live with, the four ways to reach a leaf that is already hung, the paperwork that turns blank catalogue groups into a defensible order, and the sequence that carries a door from survey to released family.
The Catalogue Row for the SLK-230, and the Three Groups It
The row below is reproduced as it stands, because a fit decision built on a paraphrase of a product record is a fit decision built on somebody's memory of a web page. Confirm on the dated product page for the specific SKU before any line in it drives a procurement decision, and read the dashes as absences rather than as values that have yet to be published.
| Field | Catalogue record for the SLK-230 |
|---|---|
| Access | RFID/IC card: Standard · Mechanical override: Standard |
| Platform & network | Platform: Hotel lock management software (PC) · Network: Standalone lock; PC-linked card encoder (no in-room network required) · Functions: Guest card issuance, floor/room permissions, check-in validity windows, unlock records |
| Body & panel | Style: RFID Hotel Card Lock · Material: 304 stainless steel · Finish: Silver |
| Power | Supply: 4 × AA alkaline batteries · Low-battery alert: Standard |
| Door fit | — |
| Packing | Carton: 570 × 355 × 345 mm · Units/carton: 10 pcs/ctn · Gross weight/carton: 22 kg |
| Capacity & versions | — |
| Environment | — |
| Services — documentation | Documentation: Dimension drawings, installation guide and full datasheet available on request |
| Services — OEM/ODM | OEM/ODM: Custom logo, finish, packaging, manuals and product configuration for distributor and project orders |
Read as a product, the row is reassuring. Card access is standard, the mechanical override is standard, the platform line names a desktop management path carrying the four functions a house actually runs on, and the body is 304 stainless steel in a silver finish — a corridor decision rather than a drill decision.
Read as a preparation instruction, the row is thin in exactly the places retrofit risk lives: no applicable door thickness, no suitable door types, no panel dimensions, no lock body or mortise geometry, no user capacity, no version list, no operating temperature or humidity range. Three blank groups in one row is not carelessness. It is a statement about what a catalogue can promise about a building, and the next section deals with why.
Why a Blank Door-Fit Line Is the Honest Kind of Record
A thickness band in a catalogue row is a promise made across every leaf a hotel owns. A factory cannot keep that promise, because door construction varies between floors, between buildings, and between the door that was replaced last year and the door that was never touched at all. What a factory can keep is a drawing set: a dimension drawing at a named revision, an installation guide, and a datasheet. The SLK-230's services line commits to exactly those three, plus an OEM/ODM scope covering custom logo, finish, packaging, manuals and product configuration.
The rest of the hotel range shows how differently the same decision can be handled. Another model in this catalogue, the SLK-9936S, records an applicable door thickness of 36–100 mm on its product page. That band belongs to that model. It cannot be read across to the SLK-230, because the two are different escutcheons over different cases, and carrying a neighbour's envelope into a new model is precisely how a leaf gets cut for a lock that will not sit in it.
So the buyer inherits a method instead of a number, and the method is the part that survives a change of mind. These slk 230 door fit notes follow that method against one model whose record refuses to publish dimensions: get the drawings, survey the leaf against them, classify the population into families, choose a route per family, pilot on the worst door, release the balance against the pilot.
The blanks also tell you that the SLK-230-F is a separate record rather than a version line. The capacity and versions group for the SLK-230 is empty, so the front-mount body is not listed as a version of the other body; it has its own catalogue entry, its own style line and its own product page. A buyer who assumes the two are interchangeable will end up with a drawing that does not match the unit on the pallet.
Front Mount Against Mortise: Two Records, Two Words Apart
The most consequential difference between the SLK-230 and the SLK-230-F is the style line, and it is the difference between a lock let into the leaf and a lock carried on it.
| Comparison point | SLK-230 record | SLK-230-F record | Why the buyer has to ask |
|---|---|---|---|
| Style | RFID Hotel Card Lock | RFID Hotel Card Lock (Front Mount) | This is the only published field that separates the two records |
| Material | 304 stainless steel | 304 stainless steel | Same body material, so the corridor-side questions are the same set |
| Finish | Silver | Silver | A presentation decision rather than a fit decision |
| Access | RFID/IC card: Standard · Mechanical override: Standard | RFID/IC card: Standard · Mechanical override: Standard | Identical, so the credential questions do not differ between the lines |
| Power | Supply: 4 × AA alkaline batteries · Low-battery alert: Standard | Supply: 4 × AA alkaline batteries · Low-battery alert: Standard | Identical, so the cell route is the same question on both lines |
| Door fit | — | — | Neither record publishes a fit value; each drawing set answers for its own body |
| Packing | Carton: 570 × 355 × 345 mm · Units/carton: 10 pcs/ctn · Gross weight/carton: 22 kg | Carton: 570 × 355 × 345 mm · Units/carton: 10 pcs/ctn · Gross weight/carton: 22 kg | Whether two lines may share an export carton is a factory question, not an assumption |
The temptation is to fill the blank with an assumption: a surface body must need no pocket, a let-in body must need one. That assumption is cheap to make and expensive to discover in a corridor. The drawings for each record are the instrument, and the question to send is short: for the front-mount body, does the case sit on the face, what is its projection into the reveal, and what does it do about the existing latch and strike?
Two other questions ride on the same choice. The first is the old hardware footprint: a body let into the leaf presents a panel over the preparation, while a body carried on the face presents its whole case on the corridor, so an escutcheon that a panel would cover may be plainly visible beside a surface case. The second is the door's construction: a body carried on the face can often be fixed to a leaf that may never be drilled, while a body let into the leaf cannot, and on an estate where some leaves are listed or part of a documented assembly, that decides which record you need on which door.
The order of decisions is fixed. Decide the mount per family, not per unit, because the two records are not interchangeable; then take the readings for that mount; then match them to the drawing set for that record. Reading first and choosing the mount afterwards is how a survey gets invalidated halfway through a programme.
The Reading Sheet: Eleven Readings That Sort a Door Population
Most of what matters about a guest-room leaf can be read from the corridor with a tape and a torch. A survey that needs the door stripped is a survey that was badly planned, and the general sequence for the work sits in the Hotel Smart Lock Site Survey, the Smart Lock Retrofit Site Survey and the Smart Lock Door Measurement Guide. The readings below are the subset a card lock on an existing room door turns on.
| Reading | Where it is taken | What it settles on the mortise body | What it settles on the front-mount body |
|---|---|---|---|
| Core build of the leaf | Close to the top edge and at the lock stile | Whether a pocket can be cut and whether the edge needs reinforcing | Whether the case can be carried on the face without working the core |
| Lock edge width | Narrowest point at hardware height | Whether the case and the spindle have material to land in | Whether the panel can sit without overhanging the edge |
| Leaf thickness at the lock stile | Three heights, extremes recorded, never averaged | Whether the fixing lengths suit the leaf | Whether the panel and its seal suit the leaf |
| Existing case pocket family | With the old set removed | Whether the door converts or has to be re-cut | Whether the leaf is acceptable as it stands |
| Old escutcheon footprint | Taken off the removed panel | Whether the new panel covers the old holes | The same question, plus whether partial coverage is acceptable |
| Bore pattern and centres | Taken off the removed panel | Whether the fixings land on existing centres | The same, where the body can be fixed over them |
| Backset and strike position in the frame | Leaf edge to the centre of the existing strike | Whether the latch reaches without moving the strike | Whether a surface case can reach the existing strike at all |
| Rebate clearance and reveal depth | Frame stop to the closed leaf face | Whether the inside panel closes without fouling the stop | The same, and more so if the body is deeper |
| Closer arm and swing projection | Inside face to the closer arm | Whether the door still latches under its own closer | The same, and the swing arc is tighter |
| Old reader side and height | Corridor face | Where a guest expects to find the reader | The same, since the guest does not know which body is fitted |
| Cell access route | Inside face, old set removed | Whether cells can be changed with the door hung | The same |
Two of those deserve a rule rather than a line. Never average a leaf: take three heights and hand the fitter the extremes, since a stiffener or a mid-rail in the core makes the same door measure differently from top to bottom. And read the rebate clearance before anything that depends on thickness, because a tight rebate can rule out a panel before any other measurement is taken.
One reading deserves its own habit: write the corridor-side observations down as a photograph with a scale in frame, beside the dimension on the drawing. A reader that sits forty millimetres from the old one, on the wrong side of the door number, produces a door that looks broken to a guest even when it works perfectly, and a picture is easier to argue with than a description.
Clearance Is a Three-Way Argument Between Leaf, Frame and Closer
Fitting a lock to a room door is one question wearing three costumes: the face has to sit over the leaf, the case has to sit inside or on it, and the latch has to reach the frame without the leaf fouling the stop on the way home.
classDiagram
class GuestRoomLeaf {
string coreBuild
string lockEdgeWidth
string leafThickness
string rebateClearance
}
class LockCase {
string pocketFamily
string backset
string followerSpacing
string spindlePosition
}
class ReaderPanel {
string panelWidth
string readerHeight
string aperturePattern
string surfaceFinish
}
class CellHolder {
string cellType
string cellCount
string accessRoute
}
class FrameAssembly {
string strikePocket
string keeperClearance
string stopFace
}
class DoorCloser {
string armType
string swingProjection
string closingSpeed
}
GuestRoomLeaf "1" --> "1" LockCase
GuestRoomLeaf "1" --> "1" ReaderPanel
GuestRoomLeaf "1" --> "1" CellHolder
LockCase "1" --> "1" FrameAssembly
ReaderPanel "1" --> "1" FrameAssembly
DoorCloser "1" --> "1" FrameAssembly
The frame is the half of the fit that the catalogue never sees, and it is usually the half that has been there for twenty years. The strike pocket was cut for a latch that no longer exists, its lining may be worn, and it sits wherever the original frame was drilled. Whether a new latch drops into it, whether it has to be moved, and whether the frame can be worked on a corridor of occupied rooms are three different questions. The measurements involved are set out in the Smart Lock Strike Plate Measurement and the Smart Lock Door Gap Measurement references.
The closer is usually the last item to be considered, and it is the one that decides whether the door closes at all. It holds the leaf at a speed and against a force chosen for the old furniture, and a card lock face changes both: it is heavier than a lever set and it stands further proud of the leaf. If the inside panel or a surface-mounted case projects further into the reveal, the door may bind on the stop before the latch is thrown, and staff read the fault as a broken lock rather than a closer that needs adjusting.
Every value in the diagram is a placeholder for a number the buyer must obtain from the drawings and the dated product page for the specific SKU. The sketch shows which measurement belongs to which object, so that nothing in the release pack is left without a source.
The Reader Face on a Stainless Corridor
304 stainless steel in a silver finish is the easiest finish decision a hotel can make and the most visible one afterwards. There is no paint match to chase and no lacquer sheen to fade into a different tone over a season. What there is, instead, is an edge. A stainless panel on a painted or laminated door draws its own outline, and the outline is the thing a guest sees.
graph LR
C["What a guest sees at the door"] --> C1["Which side the reader is on"]
C --> C2["Reader height against the old handle height"]
C --> C3["Panel width against the old escutcheon footprint"]
C --> C4["Metal edge against a painted or laminated leaf"]
C --> C5["Where the room number sits relative to the panel"]
C --> C6["Cleaning regime for a handled surface"]
C1 --> D["Which way the door is hung and which way it opens"]
C2 --> D
C3 --> D
C4 --> D
C5 --> D
C6 --> D
Because the panel does not blend, the coverage question matters more here than it would on a painted escutcheon. If the old reader or the old lever plate is not fully covered by the new panel, the leftover is not a soft mismatch but a crisp border in the wrong place. The Smart Lock Hole Coverage Guide sets out the general method, and the panel dimensions from the drawings supply the two numbers it needs.
Cleaning is the other corridor fact. A stainless surface handles a housekeeping wipe better than most painted finishes, and that is an advantage in a hotel where a handle is touched every day. It also shows every mark, and it will be cleaned more often. Any care regime named in the installation guide or the datasheet should reach the property's housekeeping team rather than living only in the maintenance file.
The panel position also has to survive the reader's working method. A card is presented flat against the face, so the guest holds a card at a height and an angle. If the reader ends up below the natural hand position of the old handle, the property will hear about it as a card-read complaint rather than as a fit problem, and it will reach the wrong team. Read the old reader height and side during the survey and put the drawing's reader position beside it before the order is placed.
Cells and Not Cables: Where the Power Sits on a Standalone Lock
The power line for this model reads Supply: 4 × AA alkaline batteries, Low-battery alert: Standard. That is the whole of the published power story, and it is a considerably more useful story than a lock that needs a cable pulled through a corridor.
A standalone lock with a PC-linked card encoder and no in-room network required removes an entire trade from the retrofit programme: no riser to open, no conduit to run, no electrician to book, no network switch to argue about. On a refurbishment of an operating hotel, that saving is usually the difference between a programme that fits inside a low season and one that does not. The published RFID Hotel Lock System Architecture and the comparison in Standalone vs Centralized Hotel Lock Systems set out the wider picture.
What cells take away is the availability of the lock itself: the battery is the only thing between a guest and a door that does not open. Three questions follow, and none can be answered from the catalogue row.
The first is the access route. The cells sit inside the lock, and a guest-room lock is changed by housekeeping while the room is occupied, which means the change happens with the door hung and somebody in the room. Whether the cell holder is reachable with the door open and nothing removed is a drawing question, and it is the difference between a quick task and a task that produces a callout.
The second is the alert. The record says a low-battery alert is standard. What it does not say is what the alert is, how it presents at the door, at what level it triggers, or whether a low-battery condition is written into the unlock records the platform keeps. Those are questions for the dated product page for the specific SKU and for the datasheet.
The third is what happens when the cells are flat. The catalogue does not record an external power override via a USB terminal for this model, so a plan that assumes a backup feed at the door is not supported by the record. The mechanical override recorded as standard is an emergency path, not a routine power method, and the two should never be confused in an operating plan.
The cadence question is the practical one. Cell life depends on how often a card is presented, how often the motor is driven, the quality of the cells and the corridor temperature, and none of those are fixed across a portfolio. The published note on RFID Hotel Lock Battery Life covers the reasoning; the figure for this model belongs in the datasheet, and the housekeeping schedule should be built from it.
The Encoder Lives on a Desk, and That Moves the Work Order
The platform line for the SLK-230 names hotel lock management software on a PC, a standalone lock, a PC-linked card encoder with no in-room network required, and four functions: guest card issuance, floor and room permissions, check-in validity windows and unlock records.
Read as a work plan, that line is mostly good news. Because the lock stands alone and the card is written at a desk, a door does not have to be brought to life by a technician standing in front of it with a phone or a laptop. Fitting a unit, fixing the strike, checking the reader and testing a card is a mechanical check that one fitter can do with a handful of test cards. That is why a card programme of this shape can roll across ninety doors without ninety commissioning visits, and it should be argued for explicitly when the programme is priced, because a competing quotation can look cheaper on labour.
Read as a credential plan, the same line raises the questions that decide whether the programme survives the handover. The card standard behind the RFID/IC card line, its read distance and the format the encoder writes belong to the dated product page for the specific SKU; they are not to be inferred from the fact that cards are involved, and they are not to be carried over from another model in this catalogue. If the property already runs cards, the question is whether the software it uses writes to a format this reader accepts, and that is a question with a written answer rather than a hopeful one.
The transition deserves its own paragraph. A floor of rooms whose cards stop working on the evening of the swap is an operational failure, not an installation detail, and the issuing path during the works has to be agreed with the property before the first leaf is opened. So do the master-card hierarchy, the housekeeping card, the maintenance card and the override key, whose presence on this model is recorded as standard but whose everyday use is a property policy rather than a hardware fact. The four functions recorded on the platform line are the vocabulary for that conversation, and the published note on RFID Hotel Lock Card Management covers the desk side of it.
Four Routes From an Existing Leaf to a Fitted Lock
A card lock can reach an existing guest-room door in four ways. Each has its own appetite, its own visible cost on the corridor and its own characteristic way of failing.
flowchart TD
A["Family named from the reading sheet"] --> B{"Leaf already carries a usable case pocket"}
B -->|"Yes"| C["Reuse the preparation and the existing strike"]
B -->|"No"| D{"Lock edge and core can take new work"}
D -->|"Yes"| E["Re-cut the pocket and bores to the template"]
D -->|"No"| F{"Leaf may be drilled at all"}
F -->|"Yes"| G["Surface conversion on both faces"]
F -->|"No"| H["Order a prepared replacement leaf"]
C --> I["Pilot on the worst door in the family"]
E --> I
G --> I
H --> I
I --> J{"Pilot meets the written release condition"}
J -->|"Yes"| K["Release the balance of that family"]
J -->|"No"| L["Revise the drawing and repeat the pilot"]
L --> I
| Route | What it consumes | What it costs the corridor | Where it fails |
|---|---|---|---|
| Reuse the preparation | The old furniture and the old panel | Almost nothing; the door is down for one fitting window | A pocket from another family, a strike pocket worn thin, holes the new panel cannot cover |
| Re-cut the leaf | The original preparation and the door finish | A second visit, because the leaf cannot close while it is worked | A hollow core, a narrow edge, a face that cannot be refinished |
| Replace the leaf | The whole leaf | A hanging window per room, scheduled rather than improvised | A frame that will not accept the new leaf |
| Surface conversion | Nothing of the leaf, but both faces are used | The slowest on site and the hardest to disguise | A tight reveal, a closer in the way, a corridor look the property will not sign off |
The first route is the cheapest and the second most common. It depends on the existing pocket belonging to the same family as the new case, which the drawings answer and the survey confirms, and on the existing strike being deep and lined enough to receive the new latch. The second route is where a refurbishment quietly runs out of money: re-cutting a painted or laminated leaf means filling, sanding and refinishing, on a corridor face that is visible from the guest approach. The third route moves the fitting work into a workshop, once per leaf rather than once per room, and it is the most predictable answer for a large estate. The fourth route is the answer for doors that may not be drilled, and the published notes on Hotel Lock Replacement Without Replacing Doors, together with Smart Lock Replacement Without Door Modification, cover that ground.
The route is decided once per family and applies to every door in it. Deciding per door is how an estate ends the programme with three different lock and panel combinations on one floor, which is a maintenance problem before it is a design problem.
The Dossier Rows That Block an Order
The output of a fit survey is not a list of doors. It is a dossier per family, with a release pack per family, short enough to write on one page. Each row has a name against it, so a blank row is visible to everyone and a completed row can be defended months later.
| Dossier row | What must be on it | Blocks the order when |
|---|---|---|
| Model record named | SLK-230 or SLK-230-F written against the line | The drawing on site and the unit on the pallet are different records |
| Drawing number and revision | The identifier and issue date of the drawing used | The line carries no drawing reference at all |
| Leaf family | Physical description, door count and room numbers | The family exists only as a filter in a spreadsheet |
| Reading sheet | The eleven readings, extremes recorded, doors identified | The readings have been averaged rather than recorded at their worst |
| Route decision | The chosen route and the reason in one line | The route was decided on site without being released |
| Pilot result | Door reference, date, outcome and the revision used | The pilot was run on the easiest door rather than the worst one |
| Release condition | The written condition the pilot was judged against | The condition was written after the pilot had already passed |
| Frame and strike position | Where the existing strike sits in the frame | Nobody has confirmed the latch will reach it |
| Cell access route | How cells are changed with the door hung and the room occupied | The change is assumed to be a quick task |
| Card and record plan | The issuing path during and after the change | Nobody owns the transition |
| Finish scope | Who fills, sands and refinishes, and when | The corridor discovers it afterwards |
The state machine below is how that pack moves. The branch that matters commercially is the one that sends a family back to the drawing rather than to the site.
stateDiagram-v2
[*] --> Registered
Registered --> Familyed: doors grouped by physical type
Familyed --> DrawingsIn: drawing and template issued
DrawingsIn --> Pilot: unit fitted on the worst door
Pilot --> Released: written release condition met
Pilot --> Redrawn: drawing revision changed
Redrawn --> DrawingsIn
Released --> Installed: unit on the door and card tested
Installed --> Archived: dossier signed and filed
Familyed --> Blocked: leaf will not accept the case
Blocked --> Respecified: route changed
Respecified --> Familyed
Two rules sit above the table. The drawing revision used on the pilot must be the revision that ships with the order, because a custom finish, a revised manual set or a project-specific configuration all move the revision. And the release condition must be written before the pilot is fitted, because a condition written afterwards describes what happened rather than setting a standard the next family can be judged against.
What the Carton Numbers Let the Logistics Team Do
The packing group on this record is populated, which is unusual in this catalogue and worth using. Carton: 570 × 355 × 345 mm. Units/carton: 10 pcs/ctn. Gross weight/carton: 22 kg.
That is three numbers, and between them they let a project build a handling plan without asking anyone for an opinion. The carton footprint is fixed, so the cartons for a given door count are arithmetic rather than a guess, and the gross weight per carton is fixed, so the weight arriving at site is arithmetic too. Because the units per carton is published, the reserve a property holds for a replaced unit can be sized in the same units.
| Published number | What it settles | What it does not settle |
|---|---|---|
| Carton 570 × 355 × 345 mm | How much space a consignment needs on a pallet, in a van or in a store | The size of an individual unit, which comes from the drawings |
| Units/carton: 10 pcs/ctn | How many doors one carton covers and how many cartons an order needs | Whether two different model records may share one carton |
| Gross weight/carton: 22 kg | What the shipment weighs and what a fitter is handling on arrival | The packed weight of a single unit, which includes its share of the carton and the packing |
| Door count in the programme | Export cartons | Gross weight in cartons | Handling note |
|---|---|---|---|
| 40 | 4 | 88 kg | Two cartons fit comfortably in a light van for a single-floor pilot |
| 91 | 10 | 220 kg | A full-floor-plus programme; the lift or stair capacity has to be checked, not assumed |
| 140 | 14 | 308 kg | More than a tonne across two buildings, which makes delivery staging a site question |
The last column is a reminder that the packing figures are the start of a handling conversation rather than the end of it. A carton at twenty-two kilograms is a two-person lift for many teams, and the threshold in a guest corridor is where a programme gets slower than anyone modelled. The published Logistics Shipping material covers the freight side; the corridor side belongs to the property's facilities team, and they should be asked what they can accept on a trolley and at a lift.
None of this touches price, order minimum or production timing. Those are commercial variables agreed in a quotation and not published in the catalogue, so any programme plan that needs them should be built around the quotation rather than around a guess.
An Illustrative Programme: Ninety-One Guest-Room Doors
Consider an illustrative scope: ninety-one guest-room doors across three floors of an operating hotel with an existing card estate and a mixed door history. This is a worked illustration of how the method handles a mixed population, and it is not a report of a project.
The reading sheet returned four families: thirty-eight doors carrying an original hotel case from a previous card system, with a pocket family and a backset the drawings recognised; twenty-six replacement doors fitted with a lighter furniture set and a tubular case; fifteen connecting doors between pairs of rooms, whose frames had been set differently and whose strikes sat where nothing in the standard range could reach; and twelve leaves the property had ruled out because they sit within a documented assembly the building must maintain.
The thirty-eight became the reuse family. The twenty-six were re-cut, and because their corridor faces were laminated they were paired with prepared replacement leaves so the finishing happened in a workshop. The fifteen connecting doors were not ordered until the drawings came back, because a frame is a different object from a leaf. The twelve were held, and the question about them went to the authority that governs the building.
A second thread ran through the same estate. The property wanted the reader positioned differently on one wing, where the door numbering scheme sat differently and the existing reader height did not match the guests' habits. Rather than argue the label, the programme carried the front-mount record as a separate line on the quotation, asked for the drawing set that covers it, and let the drawing decide whether the request was buildable. The drawing showed a different panel arrangement, so those doors were surveyed a second time rather than assumed to match the other seventy-nine.
The order went out as five lines, each carrying its own drawing reference, its own model record named on the quotation and its own pilot door. The pilots sat on the worst door in each family, and each line was then released against the pilot result rather than against a date on a delivery schedule.
Two details from that scenario travel well. The connecting doors were not ordered until the drawings arrived, which is uncomfortable but correct: ordering on a leaf survey is how a strike pocket ends up in the wrong place on fifteen frames. And the cells were treated as a service route rather than a spare part, because the housekeeping team had to accept a cell change in an occupied room before the first room was opened.
The Drawing Request That Turns the Blank Groups Into Numbers
One request, sent before the survey is scheduled, because the request is what makes the readings usable. For this model the documented offer is a dimension drawing, an installation guide and a full datasheet on request, together with an OEM/ODM scope covering custom logo, finish, packaging, manuals and product configuration for distributor and project orders.
- Dimension drawings for the SLK-230, stating the applicable door thickness band, the case pocket family and its dimensions, the backset, the follower spacing, the spindle and handle position, the panel dimensions on each face, the reader aperture pattern, how far the unit stands proud of the leaf, the handing options, and a fixing schedule with a drawing number and an issue date.
- The equivalent drawing set for the SLK-230-F at the same revision, stating where the case sits relative to the leaf face, how it interacts with an existing latch and strike, and what its projection into the reveal is. Ask which existing hardware it can be fixed over.
- The cutting and drilling template for each record and each handing, issued at the same revision as the drawings.
- The installation guide, covering removal of the old lock set, the case-fitting sequence, spindle alignment across the leaf, the access route for a cell change with the door hung, and the card test that closes the job.
- The full datasheet, carrying the power, environmental, packing and capacity lines that the catalogue record leaves empty, including operating temperature and humidity limits, user capacity and the version list if one exists.
- The power and credential specification: where the 4 × AA alkaline cells sit on each body, the low-battery alert mechanism and its threshold, whether that condition appears in the unlock records, whether any external power override exists on this model, and the card standard, read distance and written format behind the RFID/IC card line — confirmed on the dated product page for the specific SKU.
- The scope and packing questions: whether two model records may share an export carton, how the OEM/ODM scope for logo, finish, packaging and manuals affects the drawing revision, and what the instruction document the installer receives will contain.
Send the reading sheet in the same message once it exists, and ask which record each drawing covers. A supplier who answers the readings but not the record has told you that the door preparation cannot be finalised, and that is itself a decision about whether the model belongs in the programme.
Where This Note Sits Beside the Other SLK-230 Reading
One thing is covered here: how to decide whether an RFID card lock can go onto guest-room doors that already exist, and what evidence has to exist before that decision is allowed to become an order. The catalogue record, field by field and with every blank marked, is decoded in Decoding SLK-230: Specifications, Gaps and What to Ask for. What the management layer adds — issuing guest cards, setting floor and room permissions, holding check-in validity windows and keeping unlock records — is taken up in SLK-230 Access Options: What the Management Layer Adds. The checks that belong before release sit in Before You Order SLK-230: The Project Checklist.
The general references sit underneath all of it. For the mechanics and the route decisions, the Smart Lock Door Measurement Guide, the Smart Lock Retrofit Compatibility Guide and the Smart Lock Door Compatibility Matrix are the starting points, while the Smart Lock ANSI Mortise note covers the general case footprint question and the Smart Lock Door Preparation Guide covers the workshop side.
Three limits of this note should be stated plainly. The environment group in the record is empty, so nothing here fixes a temperature band, a humidity range or a weather resistance figure for this model, and the lock is described as a hotel card lock rather than an exterior unit. No door has been fitted and no dimension has been verified from reading it; the drawings and the dated product page for the specific SKU are the source, and the reading sheet is the evidence that the two were compared. And wherever a fit value for this model is discussed at all, it is named as a value to be confirmed, because the catalogue does not publish it and this note does not assert it either.
The Sequence That Releases a Guest-Room Door
The SLK-230 is recorded as an RFID hotel electronic card lock in 304 stainless steel with a silver finish, with card access and a mechanical override as standard, a low-battery alert, and a standalone arrangement pairing a PC-linked card encoder with hotel lock management software on a PC — and with no published door-fit, capacity or environment values at all. That is not a weakness in the product but a fact about its shape: it has to meet a building, and it puts the work in the drawing set and the survey rather than in a catalogue line.
timeline
title Release sequence for a guest room programme
section Evidence
Leaf survey : readings taken
Family grouping : doors sorted
section Documentation
Drawing request : issued
Template received : same revision
section Site
Pilot door : fitted and tested
Balance release : family signed off
section Records
Dossier archive : signed and filed
The sequence that resolves it runs on a property. Name the model record on the quotation — SLK-230 or SLK-230-F — and keep it there. Ask for the drawings, the template, the guide and the datasheet, and in the same message ask which record each drawing covers. Survey the population with the eleven readings an existing card lock turns on, and sort the leaves into families by their physical construction instead of by what the door schedule claims they are. Choose a route for each family, pilot on the worst door in it, and let the pilot result release the balance of that family. Carry the drawing revision, the model record and the product-page read date onto every released line, and keep the cell route and the card transition in the same pack as the fit pack.
For the drawings, the sample and the catalogue pull on this model, the routes are Request a Quote, Order Samples and Request Catalog. How the lock is made, checked and packed is a factory question. The Manufacturing process, the Quality Control regime and Logistics Shipping sit alongside the Smart Lock Manufacturer overview, with the buyer self-check material on Buyer Resources. The dated product page for this model is RFID Hotel Electronic Card Lock, and the front-mount record is RFID Hotel Card Lock Front Mount; the fit values for either come from those pages and the drawing set, with the reading sheet as the evidence that the two were compared.