A dated diary of campsites key control, following one seasonal credential reset across a border, from the site gate to the washroom block.

Veröffentlicht am: Mai 02, 2023

Smart Lock Key Control and Master Key Decisions for Campsites, Glamping and Park Lodges

Smart Lock Key Control and Master Key Decisions for Campsites, Glamping and Park Lodges

Every building type resolves into door classes, and campsites key control is organised around them. This is a working diary of one key-control decision as it crossed a border, reconstructed from the order in which the questions arrived on a factory desk between a mid-October brief and a February specification freeze. The project is a small group running a lakeside campground on one side of a national border and a coastal glamping and park-lodge site on the other. The inland site was already trading with a set of mechanical keys hanging on a board in a timber hut. The coastal site was a second phase, with a different set of building rules, a different fire authority and a different idea of what a guest's data is. The group wanted one programme: one way to issue, void and re-issue credentials at the season boundary, one answer for a lost key, one policy for who may hold a master.

  • Cluster the openings — sort the door population into classes that behave alike, starting from campsites key control
  • Assign each class — state what october file needs before anything is quoted
  • Document the fit — record the measurement that closes campsites key control
  • This is the sequence campsites key control has to follow, anchored on campsites.

Campsites key control is not the same problem as key control in a building that never closes. Three things bend it. The unit count changes every season, so the credential population is rebuilt rather than adjusted. The labour is seasonal, so the person holding the keys this October is not the person who held them last October and will not be the person who holds them next October. And the doors are outdoors or half outdoors, in rain, sun and salt, on a site where nobody is watching the gate at three in the morning.

The diary names no supplier, no operator and no market figure. Nothing here states what either side of the border requires: every regulatory, fire, building and privacy position is written as the question the buyer asks and the evidence the buyer demands, because whether a given installation falls inside a given rule is a per-site question for the local authority and the operator's own adviser. Every per-model figure is confirmed on the dated product page for the specific SKU.

Direct answer. Decide the master before the hardware. On a seasonal site a master is a decision about what one person can open, and it is far cheaper to fix in a policy than to fix in a cylinder. Then decide the reset, because the season boundary has to be a sequence the warden can run with a device in one hand and a bag of blanks in the other, with no factory, no integrator and no engineer on site. The four door classes on a campsite — the pod and lodge entry, the site gate, the washroom block and the waterside or equipment store — take four different answers, and a programme that gives them one answer will fail on at least two of them.

14 October — The File That Arrived With Two Sites on It

The brief that landed on the desk was two pages, and it was not really a brief. It was a set of assertions the group had already made about how the programme would work, and a list of things they wanted the supplier to confirm or correct.

The first assertion was that the two sites would run the same programme. The second was that the seasonal reset would happen in the week the site closes, without anyone from the supplier on site. The third was that a lost key would be replaced from a stock the warden holds. The fourth, and the one that took longest to answer, was that the site gate, the washroom blocks and the waterside or equipment store would each get a different answer.

In the illustrative scenario that runs through this diary, the inland site opens thirty-eight glamping pods and nine park lodges at the start of the season and closes most of them at the end of it. The coastal parcel adds a cluster of lodges on a second site, on a different piece of land, in a different country, with its own gate, its own washroom block and its own store. Those numbers are the group's own planning assumption for the season, and they change every year, which is the point.

Two questions arrived with the file and stayed for the rest of the winter. The first was about the boundary itself: what exactly is voided when a season closes, and who holds the authority to void it. The second was about the warden's hands: what can one person do with a bag of blanks and a device, and what needs a second person or a specialist.

The supplier's part is narrow and worth saying plainly at the start. The factory supplies hardware, the documentation that describes it and the training material that supports it. The credential policy, the decision about who holds a master and the answer for each door class belong to the operator. A supplier that starts designing the operator's master hierarchy for them has crossed a line that is expensive to uncross.

The wider due-diligence frame for that conversation sits in Smart Lock Supplier Evaluation Checklist and in Smart Lock Factory Audit Checklist for International Buyers. Neither is about this vertical specifically; both are useful because the group was buying across a border with no local presence on either side.

21 October — The Door Survey Came Back as Five Populations

The survey was supposed to be a door-fit exercise and turned into a key-control exercise, because the surveyors asked the obvious follow-up question: is there a cylinder pocket on this door at all.

The pods were uniform. New timber leaves from a kit, the same rebate, the same backset, the same hardware across all thirty-eight, which is the best news a key-control programme can receive: one cylinder profile, one blank type, one spare stock. The lodges were older and were not uniform — a mix of two rebate depths and three backsets, with a handful of doors that had been re-hung since the site opened.

The site gate was an aluminium gate on a motor post, and the gate question was not a door question at all. The washroom block was steel utility doors in a block with a service entrance. The waterside store was a steel door with a hasp and a padlock through it, which made it the one door on the site where the key, quite literally, was the lock.

That last one decided a lot. On a store with a padlock through a hasp, there is no cylinder pocket, no mortise and no escutcheon to fit an electronic lock to without changing the door or the hasp. Which means the lost-key question for that door is answered with a padlock, a blank and a shackle, not with an app. A programme that treats the store as an electronic door is a programme that will be re-specified in February.

The fit detail that decides key control is mechanical rather than electronic, and the measurement guidance in Smart Lock Door Measurement Guide is the right starting point for it. The door survey and fit argument for this vertical in more depth sits in Smart Locks for Campsites, Glamping and Park Lodges: Door Survey and Fit Reality. What matters here is narrower: a key control policy is only real if a cylinder of the right profile can physically occupy the lock body, and if it can be reached with a key blank from the cupboard.

4 November — Four Door Classes, Four Different Answers

The answer to the fourth assertion on the brief page was written as a door table. Four classes, and the group had guessed three of them wrong in the direction of over-complicating.

Door classLeaf and frame as surveyedWho legitimately opens itWhat the master is hereWhat replaces a lost credential
Pod and lodge entryTimber leaf on a timber frame, two rebate depths on the lodgesThe arriving guest and the housekeeping teamA season credential issued against a booking, never a masterVoid the booking credential at the issuing device and issue a replacement
Site gate at the barrierAluminium gate on a motor post, opened by a driveWardens on duty, and guests who paid for a barrier-free pitchA warden-held master with no guest scope at allReplace the warden master only; guest credentials are unaffected
Washroom blockSteel utility doors, public entry plus a service doorAny guest, and the cleaning contractor on the service doorNo master; the service door sits on a separate cylinderSwap the service cylinder from the blank stock, or issue the contractor a dated code
Waterside or equipment storeSteel door with a hasp and a padlock, no mortise pocketStaff on shift and the maintenance contractorA keyed override held on site, and no electronic masterA padlock blank and a shackle from the cupboard

The washroom block is the one that surprises people. It is a public door in a place where guests wander in the dark, and giving it a credential door creates a problem rather than solving one: now the door has to know who let the guest in, and the answer on a washroom block at ten at night is nobody. The correct key-control answer for the washroom block is usually that the door is not a credential door, that it opens from the inside without one, and that the only credentialed door in the block is the service entrance, which is the door the cleaning contractor needs and the guests do not.

graph LR
  A[Pod and lodge entry] --> A1[Booking credential with a validity window]
  A --> A2[Mechanical override held on site]
  B[Site gate at the barrier] --> B1[Warden master only]
  B --> B2[No guest scope on the barrier]
  C[Washroom block] --> C1[Public door with no credential]
  C --> C2[Service door on its own cylinder]
  D[Waterside or equipment store] --> D1[Named staff credential with an unlock record]
  D --> D2[Keyed override and padlock blank]

The comparison between a mechanical hierarchy and an electronic one, written up properly for a different vertical, is still the right frame here: Smart Lock vs Traditional Master Key System. What the campsite adds is that the mechanical hierarchy has a physical inventory that has to be stored, counted and — at the end of the season — destroyed, while the electronic hierarchy has a scope that has to be designed so that no single person quietly holds everything.

12 November — What a Master Key Is on a Site That Closes

The word master hides the question. A master is any credential that opens more than one door. On a site that trades year-round, that question is answered by a building's security design. On a site that closes, it is answered by a seasonal labour market.

Four options were put in front of the group.

OptionWhat it actually isWhat it costs on a seasonal siteWhere it fits
Mechanical master on a shared cylinder profileOne key profile opening several doors, with blanks cut from stock the warden holdsEvery copy is a physical object to account for; the record is a sign-out sheetStores and sheds where knowing who opened the door is not the point
Electronic master held as a scopeA credential with a broad scope, issued and revoked from a deviceNeeds power and a device at the door, plus a rule deciding who may hold itPod and lodge entries where the booking list is already digital
Mechanical override on each lock and no master at allEvery lock keeps its own keyed override and no single key opens two doorsMore cylinders to stock, and more minutes per door at closeWashroom blocks and public doors
Contractor credential with an expiryA dated code or card issued for one named jobDepends entirely on whether the expiry is enforced at the doorAnywhere a third party needs a single visit and nothing more

The group came in expecting a hierarchy of four or five levels, because that is what a hotel would have. The recommendation that survived was a hierarchy of three: the guest, the staff member on shift, and the custodian who holds the site master and signs for it. Every additional level on a seasonal site is a level that has to be re-populated with new people every spring.

One catalogue fact settled a hardware assumption the group had made. Across the seventy-nine published models in this range, sixty-three carry a mechanical override key and sixteen do not. The group had assumed a keyed override came as standard on every lock. It does not, and the sixteen models without one are the ones that cannot be fitted to a door where a physical override is the whole point. Read the access line for the model you are actually buying rather than the family it sits in, and confirm on the dated product page for the specific SKU.

The related published reading on this hierarchy is Hotel Smart Lock Master Key Management, and the mechanical side of the decision sits in Smart Lock Mechanical Key Override. The difference between this site and the hotel it borrows the vocabulary from is that the hotel's master list changes when a person leaves; the campsite's master list changes when the season turns over.

19 November — The Warden Is Also the Only Technician

This entry exists because the whole programme was quietly being designed for a building with a maintenance department, and this site has no maintenance department. In the closed season there is, on the inland site, one person on site during working hours, and nobody at all overnight. On the coastal site the winter staffing is thinner still.

That single fact reclassifies every feature in the quotation. A network reconfiguration is not a support question, because there is no support to call. A firmware update is a return-to-factory event. A dead cell at the gate on a Friday evening in July is a warden dispatch, a van and a guest with a booking for a pitch with a barrier-free pitch.

So the programme was written around what one person can do with what is in the cupboard. The warden can change cells. The warden can void a credential and issue a replacement on the issuing device. The warden can cut and fit a blank in a re-keyable cylinder at the door. The warden cannot reconfigure a gateway, replace a mortise case or re-enrol a fingerprint template set without a second trip. That list became the service boundary, and it was written down rather than assumed.

A warden key custody sheet was drafted as a one-page document: the master credentials, who holds each one, the signature on issue and on return, and the destruction line at the end of the season. It replaced a board of hooks with no list behind it. It is the same idea that the clinic vertical reaches from a different direction, and the practical training material for the role sits in Training Site Wardens to Run Smart Locks in Campsites, Glamping and Park Lodges.

The mistake to avoid here is treating the warden as an installer of software. If the season reset needs a laptop, a network and an account that only works while somebody is on a site with broadband, it will not survive a January close.

26 November — The Sample That Crossed the Border in a Case

The sample went to the coastal site first, not the inland one, because the coastal store door had the deepest rebate and the narrowest stile in the whole population. A case is a poor shipping method for a lock that must not be dropped, but it is the method available, and the point of the exercise was not the case — it was the fit.

The fit lesson is the one that would have cost the programme if the sample had gone to the easy door. On the hard door, the leaf is thicker than the standard pod leaf and the stile is narrower, so the lock case sits deeper and the escutcheon has to clear the door edge. A model whose lock case is 35 by 85 mm or 40 by 85 mm will fit where a wider case will not, and a case that does not fit is a door that has to be cut, which on a steel utility door in a washroom block is a fabrication job rather than an installation job.

The models that went into the sample box, with their catalogue lines as they stand:

ModelAccess as recordedBody and cylinder as recordedEnvironment and power as recorded
SLK-D15 weatherproof smart lock for courtyard aluminium gatesRFID/IC card, passcode, fingerprint, mobile app and mechanical override, all standardWeather-resistant broken-bridge aluminium lock body in aluminium alloy, black or silver finishWeatherproof housing, 4 × AA alkaline batteries
SLK-1104 four-in-one weatherproof smart lock for narrow-profile doorsRFID/IC card, passcode, fingerprint and mechanical override, all standardBody in stainless steel, lock case measuring 35 by 85 mm or 40 by 85 mm4 × AA batteries, external power override via a USB terminal
SLK-118 RFID card lock for hotels and B&BsRFID/IC card and mechanical override, both standardNo. 2 hotel mortise, 201 stainless steel, panel 242 by 77 by 19 mm4 × AA alkaline batteries, low-battery alert
SLK-9936S RFID hotel card door lockRFID/IC card and mechanical override, both standard5-pin high-security profile cylinder, stainless steel and alloy body4 × AA alkaline batteries, door thickness 36 to 100 mm
SLK-8831 five-in-one fingerprint keypad smart lockRFID/IC card, passcode, fingerprint and mechanical override, all standardFaceplate in zinc alloy, 227 by 66 by 20 mm, over a stainless-steel mortise caseMinus 25 to 65 degrees Celsius, 20 to 95 percent relative humidity, 4 × AA

Every line in that table is the catalogue record for the model named; check each one against the dated product page for the specific SKU before it is allowed to drive a buying decision, and read a blank field as a blank rather than as a hidden capability. The dated pages are the weatherproof smart lock for courtyard aluminium gates, the four-in-one weatherproof smart lock for narrow-profile doors, the RFID card lock for hotels and B&Bs, the RFID hotel card door lock and the five-in-one fingerprint keypad smart lock with app control.

3 December — Writing the Season Boundary as a Sequence

The reset was the heart of the brief, and it took three drafts to get right, because the first two drafts described a reset and a reset is not a sequence.

The sequence has an order to it, and the order is a security property. If the electronic credentials are voided before the physical blanks are collected, then a blank that turned up in a lost-property box in a service hut is still a working key to a door that no longer has a credential on it — the electronic side says nobody has access, and the physical side says otherwise. Collect first, then void, then destroy, and only then reissue.

flowchart TD
  S1[Freeze the booking calendar] --> S2[Collect every physical blank and card]
  S2 --> S3[Void the live credentials at the issuing device]
  S3 --> S4[Destroy the recovered blanks with a witness]
  S4 --> S5[Reset the master scope and the custodian list]
  S5 --> S6[Check the cells and swap what is low]
  S6 --> S7[Reissue the season credential set]
  S7 --> S8[Walk every door and test the manual route]
  S8 --> S9[File the register and sign the season sheet]

The sequence also has to be resumable, because a season close is interrupted by weather, by staff turnover and by a guest who is still on site in a pod in November. A reset that has to be done in one pass will be done half, and a half-done reset is worse than no reset, because it leaves the group believing the old credentials are dead.

The working document was a single sheet with nine lines, one per step, with a signature against each. Two columns, step and done, and a date. It went into the site office with the key cabinet and it did not go in the supplier's hands, because it is an operator's document and not a product feature.

That distinction matters for the reader who is comparing systems rather than products: the difference between a standalone system and one that is connected is not the lock, it is whether the reset can be run offline on site. Standalone vs Connected Smart Locks and Smart Lock Offline vs Online Architecture both circle that, and the seasonal close is where the answer shows up.

10 December — Losing One Key Without Losing the Season

The lost-key question produced the sharpest technical exchange of the winter, and it turned on a distinction the group had not made: a key can be lost in two different ways, and they have two different answers.

A lost credential that is electronic is not a lost key. It is a scope that must be reduced, and the reduction has to be possible by one person from a device without a network call to a factory. A lost credential that is physical is a lost key, and the only answer that keeps the season running is a blank.

So the site holds a small stock of mechanical key replacement blanks for the cylinder profile in use, matched to the profile of the store cylinder, the service door cylinder and the lodge cylinders. A warden who loses a key fits a blank, re-keys the cylinder at the door, and the lost key stops working the same afternoon. The alternative — a locksmith call-out, a wait, a season's worth of rooms without a store key — is the outcome the group was trying to avoid.

The condition attached to that answer is specific and is where the buying decision actually sits. The cylinder has to be a re-keyable profile with a key blank available in the right section and depth. A five-pin high-security profile cylinder and a mortise in a hotel-format lock are not the same thing, and whether a given model's override cylinder can be re-keyed on site at a door, with a blank from a cup of mixed stock, is a per-model question.

The worksheet that came out of this discussion is short enough to pin to the inside of the key cabinet:

Item in the cupboardCount at closeCarried over or replacedSigned by
Blanks for the store cylinder profile
Blanks for the service door cylinder profile
Blanks for the lodge cylinder profile
Padlock blanks and shackles for the hasp doors
Issuance device charged and signed in to the season account
Warden master credentials, one per custodian
Destruction certificate for the previous season's blanks

The final line is the one that makes the sheet worth keeping. It is the evidence that last year's credential set is dead, and it is the only thing that distinguishes a reset from an intention.

17 December — Three Doors That Take a Bumper, a Hose and a Wind

Key control is decided on the doors where the key is the most expensive thing to lose, but it is lived on the doors that take the punishment, and on a campsite those are different doors.

The gate takes a vehicle bumper, a wind gust and a post that moves in frost. The washroom block takes a hose, a mop, a trestle table carried out in the evening and a trolley that catches the wrong edge. The store takes salt, damp and a padlock that has been left off the hasp because somebody needed the door open for an hour.

The consequence for key control is specific: a door that is being damaged regularly needs a defined manual route more than it needs a strong credential. That is why the washroom block's answer included a keyed override and the store's answer included a padlock blank — not because either door holds anything worth stealing, but because a locked-out door with a broken handle on a wet weekend is an emergency call to a warden who is not on site.

The environmental record on the models matters here in a narrow way. Several catalogue models are recorded with a weatherproof housing, and one records an operating range of minus 25 to 65 degrees Celsius at 20 to 95 percent relative humidity, which is a figure worth holding against a store door that sits between a damp floor and a bright yard. Weatherproof housing is a catalogue field, not a promise about a specific installation, and the enclosure that actually covers the lock on a gate post is the supplier's question to answer, not the reader's assumption.

The load and misuse argument for this vertical, in more detail, sits in Vandalism, Misuse and Environmental Load on Locks in Campsites, Glamping and Park Lodges.

8 January — The Codes That Go Out After Dark

By January the hardware questions were settled and the policy questions were not, because the last assertion on the brief page — the after-dark code — turned out to be a key-control question wearing a guest-experience costume.

A guest arriving at twenty to ten at a site where the reception hut is unstaffed is given a code. The code is a credential with a lifetime, and the lifetime is a decision. A code that lives until the checkout time has expired on the calendar rather than on the lock, and a code that lives until the checkout time plus an hour covers the case where somebody drives back for a bag. A code that lives forever because the issuing device was left on a season setting is a key-control failure with a guest-facing face.

The property manager asked the question that decides it: if a guest forwards the code in a message to a friend who drives in for a beer, what stops that friend getting in at two in the morning? The answer is not a feature, it is a policy about how long a code lives, whether it stops at the checkout time, whether it can be voided from the warden's phone before the guest arrives, and whether the site keeps a record of which code went to which booking.

That last part is a privacy question, and it is the question the buyer asks rather than the answer anyone gives. How long is the issuing record kept, where is it kept, who can read it, and what happens to it at the end of the season.

CONFIRM-WITH-LOCAL-DATA-PROTECTION-REVIEWER. Before the after-dark code goes into the booking message, ask the local data-protection reviewer what record the site must keep of a code issued to a named booking, for how long, and whether the answer differs on the two sides of the border. Take the answer in writing and let it set the issuing policy, not the other way round.

The published guidance on codes for self check-in, written for a different operating model, is Smart Lock Guest Access Codes. The cross-border version of the same question is in Smart Locks for Campsites, Glamping and Park Lodges: Credential Model that Survives Annual Re-Issue at Season Start.

15 January — Cells, Power and the Box in the Cupboard

Power turned out to be a key-control topic rather than a facilities topic, for one reason: on an off-grid site, a lock's ability to open is the lock's ability to be trusted with a credential.

Most of the catalogue models quoted here run on 4 × AA alkaline cells, and several record a low-battery alert. The gate on the coastal site sits on a solar supply with a battery backup that is sized for the motor, not for anything else; the washroom block has no mains at all and is powered from a small solar panel on the roof. A reader and a motor both draw from the same compartment, and on a washroom block door that is opened a hundred times a day in the wet season, the cells are the consumable that decides whether the door opens.

The operational consequence for the key-control programme is that cells are part of the season-boundary sequence and part of the blank stock worksheet, because a lock that is flat at the close is a lock that will be flat at the opening, and the custodian who finds it in January is a custodian who cannot change it.

The second point is the emergency route. Some models record an external power override through a USB terminal, which is what a warden reaches for when the cells are flat and the guest is waiting. Whether the specific model carries that provision is a per-model question, and the answer belongs in the specification rather than in the warden's memory.

The wider programme sits in Battery and Power Programme for Smart Locks in Campsites, Glamping and Park Lodges and the service model around the cells in Spare Parts and Service Model for Campsites, Glamping and Park Lodges Sites.

22 January — The Coastal Site, Across the Border

The second site is where the cross-border part of this story earns its name, and the finding was uncomfortable: the credential set must not cross, and most of what the group wanted to standardise had to be rewritten.

What genuinely travels is the policy and the documentation. The door-class map, the three-level hierarchy, the season reset sheet, the RFQ clauses and the supplier's product records all cross the border unchanged. What must not travel is the credential set: a card issued at the inland site does not open a coastal door, and a warden master issued for one site should not open the other, because the two sites have different staff, different insurers and different local questions.

The things that had to be re-asked on the coastal side were the ones nobody writes down in a specification. Which authority signs off the locking arrangement on the escape routes, and whether it is the same authority as the one inland. What record of guest credentials the coastal jurisdiction expects to be kept, and for how long. What the coastal insurer asks about master key custody. Who holds the blanks, in which country, and how the stock is replenished when the season reopens — stock cannot be lent across a border, and a blank held on the wrong side of it is not a spare.

And the labour question, which was the real reason the second site cost more than the first. The inland site has a returning warden who knows the site; the coastal site is a new recruitment market every spring, with no institutional memory and a training window measured in days. That is why the warden training material was written before the hardware list was closed rather than after.

The published material on the phased approach to a multi-site programme is Phased Retrofit: Smart Locks Across a Campsites, Glamping and Park Lodges Portfolio, and the design question of how a second site inherits a policy sits in Scaling from One Site to Many: Smart Locks for Campsites, Glamping and Park Lodges.

29 January — Egress, the Alarm Interface and the Question to Ask

By the end of January the group had a credential policy, a door table and a reset sequence, and one door class it had been treating as ordinary: the washroom block and the lodge entries, which sit on escape routes.

This is the part of a key-control programme where the supplier's answer is never the answer, and where the right form of the article is the question rather than a rule.

CONFIRM-WITH-LOCAL-FIRE-AUTHORITY. Ask the local fire authority which of these doors sit on an escape route, what the locking arrangement may be on each one, and what happens to the locking arrangement when the alarm system activates. Take the answer per door, in writing, before the hardware order goes in.

CONFIRM-WITH-LOCAL-BUILDING-CONTROL-BODY. Ask the local building control body whether the proposed locking arrangement on the gate and the washroom block needs a submission, and what evidence they want with it. Confirm which authority signs off, because the fire authority and the building control body are not always the same office.

The two practical points behind those questions are worth stating plainly because they are engineering facts rather than regulatory positions. A lock with a keyed override is not an escape device, and an escape device — a panic bar or a lever exit — is a separate object that has to be specified, supplied and maintained as one. A lock that is held released by the alarm system has an interface that has to be commissioned and tested with the system that drives it, not assumed because both are on the same wall.

Whatever the answers turn out to be, one output is required: a written manual route for each door, including the door where the lock is dead and the door where the alarm is sounding, with the person who can execute each. That record is what the warden is handed at handover, and it belongs in the same file as the credential policy rather than in a drawer of its own.

5 February — The Clauses to Write Into the RFQ

The February document was the RFQ, and the clauses in it were written as questions rather than as requirements, because a requirement that names a supplier's product gets answered with a brochure.

  1. Describe the exact sequence by which every live credential for a season is voided, and the exact sequence by which the season set is reissued, including who performs each step and what equipment each step requires. State explicitly whether any step requires a factory, an integrator or a network connection.
  2. State the cylinder profile used by the mechanical override on each proposed model, whether that cylinder can be re-keyed on site with a blank held by the site custodian, and the key blank section and depth required.
  3. State which doors in the proposed configuration are opened by a master credential, and confirm that no guest-facing credential carries a master scope.
  4. State whether a mechanical override event appears in the unlock record, or whether using it bypasses the record.
  5. State the validity behaviour of a temporary or periodic passcode: whether expiry is enforced at the door when the device is offline, and what happens to a passcode that has expired.
  6. State the power source for each proposed door, the cell specification, whether a low-battery alert is provided, and whether an external power override is provided.
  7. State what the weatherproof housing on each outdoor model actually covers, and what it leaves to the site.
  8. Provide a door-by-door fit list: door class, leaf thickness, rebate and backset, and the model proposed for it.
  9. State what the supplier does not decide: the fire authority question, the building control question and the guest data question are the operator's, with the local authority's answers.
  10. Provide the documentation set: dimension drawings, the installation guide and a datasheet, on request.

The house template for a document like this is RFQ Template for Smart Locks for Campsites, Glamping and Park Lodges, and the general shape of an international hardware RFQ is in Smart Lock RFQ Guide for International Buyers. The migration argument behind clause two — why a mechanical estate is replaced by a credential set rather than by more cylinders — is set out in Migration from Mechanical Keys to Smart Locks in Campsites, Glamping and Park Lodges, and the planning of the estate's end of life belongs with Smart Lock End-of-life and Re-Keying Planning for Campsites, Glamping and Park Lodges.

12 February — Where the Programme Lands

The specification was frozen on the twelfth. What came out of it was not a lock list. It was five documents: a door table with four classes and a different answer on each, a three-level hierarchy with a named custodian for each master, a nine-step season reset with a signature against every line, a custody sheet for the blanks and the master credentials, and a set of dated questions for the fire, building and data-protection authorities on each side of the border.

The order of those decisions is the thing worth carrying out of this diary. Decide what a master opens before deciding which master to buy. Decide the reset before deciding the platform. Decide which doors are not credential doors before deciding what the credential is. And write the lost-key answer as a blank in a cupboard with a name against it, because on a site where the labour turns over with the season, that is the only answer that still works in November.

The supplier's part is narrower than the question sounds and worth restating. The factory supplies the hardware, the dated product record behind each model line and the documentation that lets a warden fit a blank and swap a cell. It does not decide who holds a master on a site it has never stood on, and it does not decide what the escape routes may do.

Send the door table and the credential policy to the factory as one document through the request a quote page, pull one physical sample to fit against the hardest door in the population through order samples, and take the dated catalogue through request-catalog so the model lines being compared are the ones that will actually be delivered.