Slk 4G door fit notes: measured door surveys, dimension-drawing requests and replacement rules for fitting the SLK-4G 4G cellular smart lock onto doors.

Pubblicato il: mag 07, 2024

SLK-4G Door Fit and Replacement Notes for Buyers

SLK-4G Door Fit and Replacement Notes for Buyers

Technology claims are cheap and verification is not, so slk 4g door fit notes is treated here as a set of checks. Door fit for a 4G cellular networked lock is two envelopes, not one. The first is mechanical: thickness, bores, backset, rail width, handing, projection, and where the strike plate lands on the frame. The second is cellular: radio coverage at the door, the SIM behind the radio, the power the radio draws, and whether a technician can still service the interior unit with the door in daily use. A lock can pass the first envelope and still fail the second, and in a retrofit programme the door population you already own sets both.

Direct answer. SLK-4G door fit notes come down to five steps: take a measured survey of every door population you are replacing, request the dimension drawings and datasheet for the specific SKU, reconcile door values against drawing values line by line, pilot one unit on the worst door in the population, and order only the doors whose rows are closed. Where the record is blank, it stays blank until a dated product page or a written supplier answer fills it.

This guide is written for the procurement manager holding a 4G lock quote against a live building. It assumes the doors already exist, which is the normal case when a cellular lock is chosen for a car park, a service corridor or an estate with no building-wide wireless network. The catalogue record for the SLK-4G leaves its door-fit and power groups empty, so this guide publishes the survey, the request list and the decision rules instead of borrowed dimensions. Every model-side value here is a blank you fill from the drawing, and every door-side value is a blank you fill with a tape measure.

What the SLK-4G Record Answers, and the Four Groups It Leaves Empty

The catalogue row for the SLK-4G, a 4G cellular smart door lock, reads as follows. The wording is quoted as it stands in the record, because a fit decision built on a paraphrase is a fit decision built on a guess.

Field groupWhat the catalogue record states for the SLK-4G
AccessRFID/IC card: Standard · Passcode: Standard · Fingerprint: Standard · Mobile app: Standard · Mechanical override: Standard
Platform and networkPlatform: dedicated 4G management app, WeChat Mini Program and PC management platform · Connectivity: 4G LTE · Functions: remote unlock, temporary/periodic passcodes, user management, access records
Body and panelStyle: 4G Cellular Networked Smart Lock · Finish: Black / Silver / Gold
Power—
Door fit—
Packing—
Capacity and versions—
Environment—
ServicesDocumentation: dimension drawings, installation guide and full datasheet available on request, plus OEM/ODM: custom logo, finish, packaging, manuals and product configuration for distributor and project orders

Every line above is quoted from the catalogue row for the SLK-4G; confirm on the dated product page for the specific SKU before you rely on any of it for a procurement decision. A dash here is not a zero and not a hidden value. It means the record carries nothing for that group, so nothing in this guide may be filled in on your behalf.

That leaves one fact doing most of the work in this article. Across the whole catalogue of 79 published models, 4G LTE connectivity is recorded for exactly one model: the SLK-4G. The wider capability counts make the same point from the other side — RFID/IC card appears on 72 models, mechanical override on 63, passcode on 55, mobile app on 41, fingerprint on 38, Bluetooth on 23 and Wi-Fi with Bluetooth on 15. Every other credential and connectivity route has a neighbour you can move to when a door refuses it. The cellular route does not.

The consequence for a fit decision is direct: a fit failure on a 4G lock cannot be solved by moving to another 4G model, because there is no other 4G model in the range. It has to be solved by preparing the door, by routing that population to a different lock class, or by fixing the service side. That is why the survey and the drawing request have to happen before the order rather than after it. The living reference for how the same 4G model is read from its paperwork is the companion piece on reading the product data sheet line by line, SLK-4G Explained: Reading the Product Data Sheet Line by Line; the credential and platform side of the same model is covered in SLK-4G Credential and Software Configuration Options.

Why a Cellular Networked Lock Adds a Second Kind of Fit Failure

A standalone keypad lock has one dominant failure mode in the field: the door does not open, and the cause is mechanical. A cellular networked lock carries a radio module, a control PCB, a motor and gearbox, a battery or cell compartment and often an emergency power port, and every one of those is a physical object occupying space on and through the leaf. The exterior escutcheon or panel has to hold a reader stack and a keypad as well as the door furniture, and the interior assembly has to hold the electronics and a serviceable power source.

None of that tells you whether it fits your doors, because the fit envelope for this specific model is the field the record leaves empty. What it does tell you is which questions are worth asking the drawing, and which answers would change your door population rather than your order.

  • Projection and mass. The exterior unit and the interior assembly each add depth. On a door with a stop, a closer arm or a tight reveal, added depth is a swinging or fouling problem before it is a fitting problem, and a panel with more electronics in it is heavier, which changes the force a closer has to work against.
  • Antenna keep-out. A radio module that sits behind a metal escutcheon, a mortise case or an aluminium profile behaves differently from one with clear space around it. Ask for the mounting position of the radio and the clear space the drawing assumes around it.
  • Interior service clearance. The interior unit has to be reachable with the door closed for battery service and for any SIM change, and it must not foul the door closer arm or the reveal.

Direct answer. The mechanical envelope decides whether the lock can be mounted; the cellular envelope decides whether the mounted lock will work. A door can be perfectly machined and still be service-dead, which is why a 4G fit survey has two columns — door geometry and site service conditions — and a door passes only when both columns close.

The service side is not a footnote here. Wi-Fi with Bluetooth appears on 15 models and Bluetooth on 23 in the catalogue's connectivity picture, while 4G LTE appears on one. Buyers usually arrive at a cellular lock because the site has no usable wireless coverage at the doors they care about, which means the signal question is a question about those specific doors rather than about the building. The wider radio-path trade-offs are laid out in Smart Lock Network Requirements and Smart Lock Gateway vs Direct WiFi: An Architect's Dialogue on Choosing the Radio Path for a Multi-Site B2B Estate.

The Six Measurements That Decide Whether a Door Takes the Lock

Six measurements, taken the same way on every door, turn a fit argument into a register. The method behind each one is set out in the published Smart Lock Door Measurement Guide, with the dedicated treatments for Smart Lock Door Thickness Measurement, Smart Lock Backset Measurement, Smart Lock Door Gap Measurement and Smart Lock Strike Plate Measurement.

MeasurementWhat it settles on the doorHow it is readWhere a wrong value surfaces
Thickness at the lock edgeWhether the two halves clamp the leaf correctly and the fasteners have usable lengthCaliper on the closed door's lock edge at three heights; record extremes separatelyFitting — a unit that rocks, or bolts that protrude inside
Cross bore diameterWhether the body enters the hole already in the door, or new cutting is neededRule down the bore; compare against the drawingCutting — a body that will not enter, or a gap around the case
Edge bore and case pocketWhether the latch and deadbolt can reach the strike in the existing prepMeasure the pocket depth and the edge bore at the same referenceCommissioning — a latch that binds or a bolt that stops short
BacksetWhere the mechanism sits from the edge and whether the latch meets the strikeEdge to bore or spindle centrelineCommissioning — the strike plate is in the wrong place
Lock-edge rail widthWhether there is enough solid material to carry the bore and the fixingsNarrowest reading on the lock-edge face at hardware heightCutting — breakout into a panel or a void
Handing and swingWhich face takes the exterior unit, where the latch points, which jamb takes the strikeRead from the hinge face, then classifyAfter install — the lever is on the wrong side or the latch bevel fights the strike

No dimension qualifies alone. A door can be a correct thickness, correctly bored and correctly handed, and still have a rail too narrow to carry the case without breaking into the panel. Fit is the intersection of six sets, and the register is what proves the intersection is not empty.

Three discipline points keep the register usable. Record minimum and maximum rather than a mean, because a door that tapers 2 mm across its height is a different order than a door that is uniform. Measure at the height where the hardware will actually sit, not at the middle of the leaf. And record the leaf material, because a hollow-core leaf, an aluminium profile and a solid timber leaf take the same fixing differently.

A worked example of what a completed envelope line looks like is available in this catalogue: the SLK-9936S hotel lock publishes a door thickness of 36–100 mm, and the SLK-9905A hidden-reader model publishes approximately 38–100 mm. Those are useful as format examples — a band expressed as minimum and maximum, tied to one named model — and dangerous as values borrowed for anything else. The SLK-4G does not publish a thickness band in its record, so it does not have one here. The full method behind that distinction sits in the SLK-9936S Door Thickness Compatibility Guide and the SLK-9905A Door Thickness and Compatibility Guide.

Reading the Dimension Drawing as a Commitment, Not an Illustration

The services row of the SLK-4G record commits to dimension drawings, an installation guide and a full datasheet available on request. That is the entire legitimate source of fit values for this model. The drawing is not a marketing render; it is the document that lets a buyer reject a door before ordering and lets an installer cut without a site visit.

Request the drawing and read it as a set of commitments with acceptance rules attached. Each line below is a line you should be able to quote back.

Line to find on the drawingA usable answer looks likeA weak answer looks like
Thickness bandA stated minimum and maximum at the lock edge, in one unit, with the door state definedA single nominal thickness with no band
Bore and pocket geometryBore diameters and case pocket dimensions, with tolerances"Fits standard doors"
BacksetA fixed value or an adjustable range with the range statedNo backset line at all
HandingA statement of whether the unit is reversible or supplied handed, per handingOnly a picture of one handing
ProjectionExterior and interior depth from the door facesA plan view with no dimensions
Service clearancesThe space needed around the interior unit for power and for any SIM changeNot drawn
Template and fixing patternA cutting template supplied as a document, with the screw pattern dimensionedA photo of an installed lock
Radio positionWhere the module sits and the clear space the drawing assumes around itNothing
RevisionA drawing number and date that can be tied to the firmware and hardware you receiveAn undated sheet

Two questions about the drawing decide how much weight it can carry. Does it describe the hardware you are buying, or a family of variants? And does it match the revision that will be in the box? The request should specify the drawing revision and the SKU it applies to, so that a later argument about a 2 mm interference is about a document both sides hold.

Do not treat the drawing as a substitute for the survey. The drawing describes what the lock needs; the register describes what the doors have. Both are required before a verdict, and the verdict is only as good as the weaker of the two.

Mapping the Doors You Are Replacing Instead of the Doors You Want

A retrofit programme is an archaeology project. The doors carry the record of whatever builder, renovation and facilities team touched them last, and the fit question is not what the building should have but what it has. Grouping the doors into populations first turns a long list of surprises into a short list of decisions.

Door populationWhat you will find on siteWhat the population demandsWhat to capture
Mortise-prepared doors, recentA case pocket, euro-profile cylinder hole, follower holesUsually the cleanest population for a networked lockPocket dimensions, cylinder position, follower spacing, backset, handing
Refurbished doors with a legacy cylindrical prepA 2-1/8 in style cross bore and a separate edge boreA decision between a cover plate, a new pocket or a different modelExisting bore diameter, edge bore, what furniture currently covers them
Narrow-rail or aluminium profile doorsA hollow section with a thin wall at the lock edgeA rail-width decision that can move a population out of this modelWall thickness, rail width, section profile, whether the screw thread is sound
Glazed or frameless doorsNo leaf to bore, a glass patch fitting insteadA completely different fitting approach, and a different order lineGlass thickness, gap between leaves, patch fitting family, swing direction
Steel or heavily prepared security doorsExisting prep, multi-point hardware, often a filled edgeRarely a re-cut; usually an agreement about reuse or exclusionPrep standard, existing hardware schedule, edge condition

The register is one row per door, or per door class with a recorded count when the population is genuinely uniform. The rows that matter are the ones that can reject a door: the geometry, the rail, the handing, the material, and the prep condition. The published Smart Lock Old Lock Replacement Guide covers the removal and reinstallation mechanics, while the Smart Lock Retrofit Compatibility Guide covers how existing preps are classified before a model is chosen.

Two numbers make the register defensible. Record the count of doors in each population so that the order can be split. And record which measurement you are least sure about on each population, because that is where the pilot door should come from.

Six Replacement Geometries and What Each One Asks of You

Once the door is classified, the replacement question becomes concrete. The geometry of the existing prep decides whether the new lock reuses the door, modifies it, or leaves it alone.

1. Like-for-like on a mortise-prepared door. The best case, and it still needs a case-family check. The new mortise case must be the same family as the pocket in the door, with the same follower spacing and the same cylinder profile. Where the old lock was a hotel-class unit with a euro-profile cylinder, that cylinder position is inherited, and a lock with a different cylinder expectation does not reuse it.

2. A legacy cylindrical or ANSI cross bore. The door has a round hole and an edge bore. Three routes exist: an escutcheon wide enough to cover the old cross bore, a new pocket cut into the door, or a different model class designed around the cylindrical prep. The route you pick has consequences downstream — covering the old bore leaves the old edge bore exposed unless the new escutcheon or a plate handles it. The Smart Lock Hole Coverage Guide sets out how to check whether a new panel can hide an old hole.

3. A narrow-rail or aluminium profile door. Here the rail width governs, not the thickness. The published SL-6301 Narrow Edge Door Compatibility is a worked example of a narrow-edge product class and of how a rail measurement decides the model, and the SLK-G200 Glass Door Thickness Guide covers the glazed case where the patch fitting replaces the mortise case altogether.

4. A glazed or frameless door. The order line changes shape entirely. There is no bore, the fixing is a glass door patch fitting, the gap between leaves becomes the governing dimension, and the radio position inside a patch fitting is worth asking about specifically. The Smart Lock Door Compatibility Matrix is a useful published cross-check when a population spans glass and timber.

5. A steel or heavily prepared security door. The default answer here is reuse of the existing prep or exclusion of the door from the programme. New cutting into a prepared steel edge is slow, and the fixings have nothing to bite into. Record what is there and decide in writing.

6. A rated or fire-rated assembly. This is a routing decision, not a lock decision. Any new hole in a rated door is a question for the documentation that governs that door set and for the authority that signs it off. The correct output of the survey is a blocked flag with a named owner, not an order line.

CONFIRM-WITH-LOCAL-INSURER — whether the access and escape provisions required for the doors being replaced are met by this lock configuration and its installation. Verify the scope for each door class, and do not treat a product-page entry as a compliance answer.

Two reconciliation points apply across all six. The strike plate and the frame rebate must be checked against the new latch and backset — the Smart Lock Strike Plate Measurement page covers the frame side, and frame rework is scope, not luck. And the mechanical override path, cylinder position and rose or collar must be checked against the interior face, because the old lock's cylinder hole and the new one often want different positions. The Smart Lock Replacement Without Door Modification page covers the case where the door is not to be touched at all, which is a legitimate and under-used option in a replacement programme.

The Cellular Envelope: Signal, SIM, Power and Service Access

The record's power group is empty, so the power and service questions cannot be answered from the catalogue. They have to be put to the supplier in writing and checked against the site. Four clusters of question cover it.

Service questionWhy it belongs in a fit orderWhat to obtain
Coverage at the doorCoverage at the office says nothing about a basement, a courtyard or a rear entranceA coverage check at the actual door positions, carried out or evidenced before the fleet order
Radio locationA lock carrying its own module and a lock reached through a gateway have different installation and different failure modesWhether the model is directly cellular, gateway-dependent, or configurable, on the dated product page
SIM and operatorThe SIM carries an operator relationship, a format and a recurring cost that somebody ownsWhich market's operators are supported, the SIM format, who provisions and who pays
Service accessA SIM change and a battery change both need the interior unit reachable with the door closedInterior clearance, access path, and whether service can happen with the door shut

On power specifically, the blank row means you must request the whole set rather than assume it. Ask for the power source and cell type, the expected operating behaviour and cycle count, the low-battery alert behaviour, and whether an external power override via a USB terminal is available. Each of those is a line the record leaves empty, and each changes how you specify the power box, the maintenance route and the service contract. The catalogue glossary uses external power override via USB terminal and low-battery alert as the standard terms, and so should your request.

Two axes decide the order before any number is filled in: how much mechanical preparation the door needs, and how hard the site is to serve. A population with low preparation risk and strong coverage is the easy case. A population with high preparation risk and weak coverage is the one that must be resolved before it becomes an order line.

quadrantChart
    x-axis Low mechanical prep risk --> High mechanical prep risk
    y-axis Strong cellular coverage --> Weak cellular coverage
    quadrant-1 Prepare the door before ordering
    quadrant-2 Route the population elsewhere
    quadrant-3 Pilot then fit as ordered
    quadrant-4 Fix the service side first
    "Apartment entrance doors": [0.18, 0.24]
    "Refurbished doors with legacy bore": [0.58, 0.28]
    "Aluminium courtyard doors": [0.82, 0.66]
    "Basement car park doors": [0.72, 0.88]

The fourth quadrant is the one that catches people. A steel car-park door that is already well prepared and sits in a signal-poor basement looks like an easy fit on the drawings and turns out to be a service problem, not a preparation problem. Deciding which quadrant a population sits in before you order is cheaper than discovering it at commissioning.

The Fit Dossier and the Rows That Block an Order

Two sets of values meet in the middle: yours from the register, the supplier's from the drawing and the written answers. The dossier is the document that holds both, and its purpose is to make an empty cell visible before it becomes an order line.

Dossier rowYour value from the registerSupplier answer to obtainAcceptance ruleBlocks the order?
Applicable door thicknessMinimum and maximum per doorPublished band for this SKURegister extremes fully inside the bandYes
Cross bore diameterExisting bore per doorRequired boreReuse, enlarge or new cut — recorded per populationYes
Edge bore or case pocketExisting pocket and edge boreRequired geometryEither reuse or a signed cutting scopeYes
BacksetEdge to centre per doorFixed value or adjustable rangeExact match, or a range that covers itYes
Lock-edge rail widthNarrowest readingMinimum rail widthAny door below it leaves the populationYes
HandingCounts of each handingReversible or supplied handedWrong answer mis-orders a populationYes
Exterior and interior projectionClearance available each sidePublished projectionMust clear the stop, the reveal and the closerYes
Power source and cell typePower route and service accessPower specification for this SKUServiceable with the door closedYes
Low-battery and power override—Alert behaviour and override availabilityNamed in the written answerYes
Radio position and clear spaceSpace behind the escutcheonMounting position on the drawingNo metal obstruction assumedYes
Coverage at the doorSignal condition per populationWhether the model serves the site as foundEvidence before the fleet orderYes
SIM and operator supportMarket per doorSupported operators and SIM formatNamed in the written answerYes
Mechanical override accessKey custody planKey and cylinder provision per unitCustody written before the orderYes
Template and installation guide—Supplied as documentsNo template, no field-cutting commitmentYes
Spare parts and service kit—Availability of panels, cells, modulesNamed for the programmeNo, but note it

The rule that makes the dossier work: a door cannot receive a pass verdict while any model-side row is still empty. An empty cell is a blocking item with an owner and a date attached, not a footnote. This is the same discipline the published Smart Lock Model Selection Matrix applies to choosing between models, applied instead to a single model against a single door population.

erDiagram
    DOOR_CLASS ||--o{ DOOR_ROW : "holds one row per door"
    DOOR_ROW }o--|| FIT_VERDICT : "bucketed as"
    DRAWING_LINE ||--|| FIT_VERDICT : "gates"
    SERVICE_LINE ||--o| FIT_VERDICT : "gates"
    DOOR_CLASS {
        string class_id "one door population"
        string vintage "what the door was built as"
        string prep_found "hardware and prep on site"
    }
    DOOR_ROW {
        string door_id "survey register entry"
        string thickness_extremes "minimum and maximum at the lock edge"
        string rail_width "narrowest solid material"
        string handing "right left and reverse"
    }
    DRAWING_LINE {
        string dimension "one line of the drawing"
        string supplier_answer "blank until requested"
        string acceptance_rule "how the door value is judged"
    }
    SERVICE_LINE {
        string service_item "coverage sim power access"
        string supplier_answer "blank until requested"
        string acceptance_rule "condition at the door"
    }
    FIT_VERDICT {
        string outcome "one of three verdicts"
        string owner "the person who signed it"
    }

Only three verdicts exist, so the register cannot drift into opinion. Fits as ordered means every row closed and every value inside the envelope. Fits with documented preparation means one dimension sits outside and a named treatment has been signed by a person. Not this model or blocked means a dimension falls outside the envelope, a model-side row is still empty, or the door raises a question for somebody other than the supplier. A population with three verdicts in it is two populations, and it should be ordered as two.

Piloting the Worst Door in the Population Before the Fleet Order

One physical unit, fitted on one real door, settles arguments that a spreadsheet cannot. The pilot is not a formality and it should not be spent on a good door, because a pilot on a good door proves that the box was complete.

Choose the worst borderline member of each population: the narrowest rail, the odd backset, the reverse-hand door, the outward-opening leaf, the door with the legacy bore nobody has measured, and the population with the weakest coverage. If the same unit type has to cover several populations, pilot the one where the failure would be most expensive.

Test on the pilot doorWhat it provesWhy it cannot be done at the desk
Cut-out and mounting against the drawingThe drawing matches the hardwareA template error is invisible until a hole is drilled
Latch and deadbolt travel with the door closed and liftedThe strike geometry works in the real frameA latch that binds looks fine on an open door
Key override on the installed leafThe mechanical path suits the thicknessThe cylinder length is a thickness-dependent dimension
Interior service access with the door shutBatteries and any SIM change are reachableClearance problems appear on site, in daylight, with the door open
Every declared credential through the closed doorThe reader stack works at the mounting positionA reader that works in the hand can fail at a door
Remote unlock and event records from the siteThe radio path serves this doorRemote functions are the ones that fail quietly, from the wrong location
Coverage check at that doorThe cellular assumption holdsA coverage problem is invisible until the first customer needs entry

Record the pilot in writing, with the door identifier, the measurements taken on the day, the unit's own identifier, and the result of each line. That record is the evidence for the fleet order and the baseline for the installer who follows you onto the next floor. The published Smart Lock Commissioning Checklist covers the wider sequence beyond the pilot door.

An Illustrative Scenario: 186 Doors Across Five Door Generations

Consider an illustrative retrofit of a 186-door mixed estate: a twelve-storey serviced residence with ninety-six apartment entrances, a ground-floor retail arcade, a basement car park and a service corridor. The operator wants remote unlock and a central access record at the car park and service doors, and there is no building-wide wireless network, so a 4G cellular lock is the logical candidate. This is an illustrative scenario, not a project record.

The first survey returned 186 doors in five populations, and only one of them looked like a single order line. Ninety-six apartment entrance doors were mortise-prepared timber, uniform in thickness, consistently handed, with a euro-profile cylinder hole and a case pocket of the right family — the cleanest population, closing as fits as ordered once the drawing lines for pocket geometry, backset and handing came back in writing.

Forty-four refurbished doors carried a legacy cylindrical cross bore and a separate edge bore from an older fitting. These closed as fits with documented preparation, each carrying a plate and a signed treatment, provided the new escutcheon was wide enough to cover the old bore — which is why the hole coverage check happened before the order and not on site.

Eighteen aluminium courtyard doors had a narrow hollow rail. The measured rail ruled them out of this model regardless of how the drawing read, and they were routed to a different lock class with their own survey.

Fourteen basement car-park doors were steel, already prepared, mechanically comfortable — and in a level where the coverage check came back weak. Those went into the service-side exception file: the pilot had to happen on one of them before any of the fourteen was ordered.

Twelve arcade street doors had been prepared for a hotel-class mortise case with a different follower spacing, so the case family was a mismatch; they were separated onto their own line pending a case-family answer. Two stair doors were rated assemblies and were routed to the documentation holder for that door set, marked blocked rather than ordered.

The result was an order split into three lines, one exception file and one authority routing, all decided in the survey phase. The lesson for a procurement manager is not the numbers in this illustration. It is that a single-line order is the most expensive document a fit survey can produce, because it means the survey was skipped.

How Fit Failures Arrive Months Later Wearing a Different Name

Fit problems are rarely reported as fit problems. They arrive as a service call, a complaint, a returned unit or a network fault, and by then the evidence that would have settled them has been lost. Mapping the symptom back to its cause is what keeps a replacement programme out of that loop.

What gets reportedThe likely cause underneathThe check that settles it
The door does not open; the bolt is half thrownLatch alignment against a strike plate set for the old backsetPush the door closed and lift it while operating the handle; measure the strike position against the new backset
The unit is intermittent on some doors and fine on othersFixings under-torqued or a rail too narrow for the fastenerCompare the register's rail reading against the drawing's minimum; check the torque on the actual door
Batteries drain faster than expected on a few doorsRadio signal quality driving repeated reconnection, or a cell set that does not match the specificationCompare the affected doors' coverage against the doors that behave; check the power specification against the cells supplied
A card that worked on the old lock is refusedThe credential standard behind the record line is not the standard in your card fleetConfirm the card standard and read distance on the dated product page for the specific SKU before migrating a fleet
The door closes hard or drifts openPanel weight and projection changing the closing behaviour against an unchanged closerCheck the closer against the new panel weight and the new interior projection
Remote unlock works everywhere except one doorCoverage at that door, or a radio position against metalRepeat the coverage check at that door with the panel mounted as it will be

The pattern worth internalising is that mechanical misalignment reports itself as an electronics fault. A motorised bolt pushing against a misaligned strike loads the mechanism, the mechanism draws more current, and the first symptom a user or a monitoring dashboard shows is a battery or a radio fault. Before you accept an electronics diagnosis on a door that failed soon after a retrofit, prove the mechanical path by hand: the latch should throw freely on an open door and the bolt should enter the strike without the door being lifted.

The Stage-Gated Sequence from Survey to Purchase Order

A retrofit order built on measured doors has a natural sequence, and each stage has an exit condition that can fail. The gates below are the working order for an evaluation-stage buyer who intends to place a project order once the fit question is closed.

flowchart TD
    A[Record the blank model-side rows] --> B[Survey every door population]
    B --> C[Request drawings and written answers]
    C --> D[Reconcile door values against drawing values]
    D --> E{Fit verdict}
    E -->|Pass| F[Order the standard line item]
    E -->|Preparation| G[Order with a signed preparation scope]
    E -->|Not this model| H[Route the population to another class]
    F --> I[Fit a pilot on the worst door]
    G --> I
    I --> J[Release the fleet order]

Gate 0 — record the blanks. Write down every field the model record leaves empty before you contact anyone. For the SLK-4G that is the door-fit group, the power group, packing, capacity and versions, and environment. A blank you have written down is a blank you can close.

Gate 1 — survey. Every door population measured, counted and classified, with the least certain measurement flagged. Exit condition: a register with a row per door and no empty geometry cell.

Gate 2 — request. The drawings, the installation guide, the datasheet, the power specification and the service answers, all against a named SKU and a dated revision. Exit condition: a dossier with the model side filled, or a written refusal on named rows.

Gate 3 — reconcile. Each register row against each drawing row, with an acceptance rule applied. Exit condition: every door carries one of three verdicts, and no door carries a pass verdict with an open model-side row.

Gate 4 — order in lines. One line per verdict and per population, with preparation scopes and exception files separate. Exit condition: a purchase order whose lines match the register, which is where the companion SLK-4G Purchase-Order Checklist: What to Confirm Before Ordering takes over.

Gate 5 — pilot. One unit per borderline population, on the worst door, with the test script above. Exit condition: a signed pilot record.

Gate 6 — release. The fleet order, the installer pack and the commissioning record. Exit condition: the installer's pack contains the drawing revision and the pilot record, so the crew cuts from the same document you reconciled against.

The Document Request That Precedes Every Fit Order

Send this list before you send a purchase order, and amend it to match the programme. It is written so that a supplier can answer it row by row without guessing.

  1. Dimension drawings for the SLK-4G, showing the applicable door thickness band, cross bore, edge bore and case pocket, backset, handing, exterior and interior projection, fixing pattern and service clearances, with a drawing number and a date.
  2. The cutting template, supplied as a document, for each handing you need, matching the drawing revision.
  3. The installation guide, and the full datasheet, for the same SKU and revision.
  4. The power specification: power source and cell type, expected operating behaviour and cycle count, low-battery alert behaviour, and whether an external power override via a USB terminal is available.
  5. The connectivity specification: whether the model is directly cellular, the radio position on the lock, and the supported operators and SIM format per market.
  6. The credential specification: the card standard behind the RFID/IC card line, read distance, and the fingerprint sensor's working conditions, all confirmed on the dated product page for the specific SKU.
  7. The environment specification, and the spare-parts position: operating temperature and humidity limits, weatherproof housing availability, and the availability of replacement panels, cells and modules for a distributor or installer to hold locally.
  8. The packaging specification: carton dimensions, units per export carton and gross weight per carton, so the delivery and handling plan can be checked against the site.
  9. The OEM/ODM scope available for distributor and project orders: custom logo, finish, packaging, manuals and product configuration, with the effect of each on the fit documentation and the packaging route.

Send the survey register and the drawing request in the same message. A supplier who replies to the register but not the drawing has told you the drawing will not exist, which is itself a fit decision you can act on. When the answers come back, run them through the dossier before they become an order, and keep the dated product page with the file.

For a quote that answers the register against your own doors rather than against a generic door, send it through the request a quote page, and pull one physical sample to pilot on the worst door through order samples. The model itself is listed as the 4G cellular smart door lock on the site, where its current published specification and finish options are set out. What you should take from this guide is the discipline rather than the numbers: measure every door, obtain the drawing for the exact SKU, refuse a verdict built on an empty cell, and pilot the worst door before the fleet order leaves the factory.

Il tuo carrello
La tua esperienza su questo sito sarà migliorata consentendo i cookie Informativa sui cookie
Chat on WhatsApp