Ansi bhma a156 23 versus ansi bhma a156 25 applicability: use this checklist to determine whether ANSI/BHMA A156.23 or A156.25 fits a smart lock door.

Đăng lúc: Th09 19, 2025

Ansi/bhma A156.23 Versus ANSI/BHMA A156.25: Which One Applies to Your Smart Lock Door

Ansi/bhma A156.23 Versus ANSI/BHMA A156.25: Which One Applies to Your Smart Lock Door

The qualification question ansi bhma a156 23 versus ansi bhma a156 25 applicability is answered by identifying the locking device before naming the standard. ANSI/BHMA A156.23 and A156.25 can appear on one project, but they do not test the same thing. This tear-off sheet helps procurement record the decision, evidence request, and open supplier questions.

Direct answer. On ansi bhma a156 23 versus ansi bhma a156 25 applicability, this article uses ansi bhma a156 23 versus ansi bhma a156 25 applicability as the definition. It treats ansi bhma a156 23 versus ansi bhma a156 25 applicability as a working definition specific to this market and product

A published standard describes what it tests; it does not establish that a site, product, or installation is certified. Certification status is CONFIRM-PER-SUPPLIER and must rest on dated, traceable documents.

1. Identify the door’s locking function

Mark the door’s primary mechanism, not the product category. A “smart lock” may include a latch, motor, reader, relay, and strike, but those elements do not automatically determine the applicable standard.

Door functionFamily to investigateQualification note
Electromagnetic lockANSI/BHMA A156.23Holding force, duty, indoor/outdoor scope
Electrified locking device not covered elsewhereANSI/BHMA A156.25Cycling, security, operation, strength and environmental tests
Smart lock with internal electrical controlFit against current A156.25 scopeDo not decide from product wording
Electric strike or frame-mounted actuatorANSI/BHMA A156.31Keep this adjacent family separate

The electromagnetic lock standard is ANSI/BHMA A156.23, covering holding force, duty, and indoor or outdoor scope. The electrified locking device standard is ANSI/BHMA A156.25, covering cycling, security, operation, strength, and environmental tests where the electrical function is not covered elsewhere. A156.25 is the closest BHMA family for electrified lock hardware, but the current published scope still controls. Specifications at this level come off the smart door locks.

2. Run the applicability decision

For the ansi bhma a156 23 versus ansi bhma a156 25 applicability record, use this sequence:

  • Primary device is an electromagnetic lock? Candidate A156.23.
  • Primary device is an electrified locking device not covered elsewhere? Candidate A156.25.
  • Electric strike or frame-mounted actuator? Route to A156.31.
  • Multiple mechanisms? Ask for a written scope rationale for each.
  • Door use or assembly needs another assessment? Carry it forward.

Record “ANSI/BHMA A156.23 applicability” and “ANSI/BHMA A156.25 applicability” as separate determinations. If a product combines functions, request a scope rationale for each; do not turn one report into blanket coverage.

flowchart TD
    A[Identify locking device] --> B{Primary device is electromagnetic}
    B -->|Yes| C[Investigate A156.23]
    B -->|No| D{Electrical function covered elsewhere}
    D -->|Yes| F[Route to another applicable family]
    D -->|No| E[Investigate A156.25]
    E --> G[Verify scope edition and exact SKU evidence]
    C --> G

Readers comparing approaches usually start with smart lock price by access method. That is the same question ansi bhma a156 23 versus ansi bhma a156 25 applicability has to answer here.

3. Verify the edition and product scope

Before requesting evidence, check the published title and scope of the current edition of each candidate. Route every clause-level question to the published standard text. Match the proposed mechanism, configuration, intended environment, and exact SKU or variant to that scope.

This overlaps with the earlier coverage in the smart lock certification cost. That is the same question ansi bhma a156 23 versus ansi bhma a156 25 applicability has to answer here.

  • Standard designation and current edition recorded.
  • Tested function matches the proposed function.
  • Model, variant and relevant options identified.
  • Written clarification obtained for scope ambiguity.
  • Unrelated standards and claims left outside the declaration.

Qualification record: ansi-bhma-a156-23.

4. Separate the four evidence documents

Ask the supplier to label every attachment. These documents are not interchangeable:

DocumentWhat it establishesMinimum qualifier
Test reportSomeone tested a sampleStandard, edition, tested model and report date
CertificateA body attests conformityScope, number, issuer and validity
Declaration of conformityManufacturer or importer makes its own legal claimSignature, date and product identification
MarkingA market mark is printed on the product or labelProduct or regime identity, not broader proof

A supplier saying it has a certificate must identify which of these four it means. Require the document name, issuer where applicable, scope, number, date and validity in the response.

CONFIRM-WITH-LOCAL-AUTHORITY: Confirm with the local authority having jurisdiction and the importer which declaration, marking and inspection requirements apply to the specific purchase.

5. Work up the evidence-quality ladder

Use The evidence-quality ladder that governs ansi bhma a156 23 versus ansi bhma a156 25 applicability runs: marketing image → self-declared DoC → test report on a sample → third-party certificate with scope + number → certificate covering the exact SKU/variant you are buying → audit evidence showing the approval still holds after the sample passed

For smart lock procurement evidence, move up this ladder until the document identifies the exact product and mechanism. A sample report or self-declared DoC does not prove coverage of the purchased variant. For deeper review, use Ansi/bhma A156.23 for Smart Locks: Scope, Tests and What the Standard Never Proves for scope limits, Reading an ANSI/BHMA A156.23 Test Report Page by Page: A Smart Lock Buyer Walkthrough for report anatomy, Three Ways ANSI/BHMA A156.23 Evidence Disappoints Smart Lock Buyers for evidence failures, and Who Pays for ANSI/BHMA A156.23 Evidence in a Smart Lock OEM Programme for ownership.

6. Keep adjacent requirements separate

Lock-hardware performance, fire-door assembly, access-control system, electrical safety and accessible operation answer different questions. A156.23 and A156.25 do not replace NFPA 80 for a fire-door assembly, UL 294 for access-control system units, or UL 1034 for electrically controlled lock safety and performance. Keep electric strikes and frame-mounted actuators with A156.31. Check each current published scope rather than stacking marks in a generic claim.

CONFIRM-WITH-LOCAL-AUTHORITY: Confirm with the local authority having jurisdiction and the door manufacturer which egress, fire-door, accessibility and electrical requirements apply to the installed assembly.

Use Office Smart Lock Site Survey to capture site conditions separately from the standards decision.

7. Issue the RFQ clause and complete the sign-off

Put the selected family in the RFQ only after completing the device decision. A usable clause is:

Evidence is requested against the current edition of [A156.23 or A156.25, justified by the locking function] for the offered [SKU]. The response shall identify the tested sample, certificate scope and number where applicable, issuer, validity, exact model or variant, and production-control evidence. A marking or declaration of conformity shall not substitute for scope-matched documents.

Complete these tear-off fields before release:

FieldProcurement entry
Primary locking function
Candidate family and reason
Current edition and scope checked
Document type, number and issuer
Exact SKU or variant match
Open door or local questions
  • Scope matches the proposed function.
  • Document type is explicit.
  • Exact SKU or variant is linked.
  • Open questions have written answers.

Send the completed tear-off sheet with the RFQ and require bidders to answer open evidence questions against the identified scope, not a generic “ANSI compliant” statement.

When the file is ready, request a quote against the written requirement.

Giỏ hàng của bạn
Trải nghiệm của bạn trên trang web này sẽ được cải thiện bằng cách cho phép cookie Chính sách cookie
Chat on WhatsApp