South africa door thickness survey worksheet: use this South Africa and East Africa survey worksheet to capture door thickness, backset, frame context.

Diperbarui pada: Jun 06, 2025

Door Thickness and Backset Variance in South Africa and East Africa: A Survey Worksheet

Door Thickness and Backset Variance in South Africa and East Africa: A Survey Worksheet

Use the south africa door thickness survey worksheet as the controlled record for every opening that may receive an electronic lock. It separates measurements from assumptions, letting a consultant compare the door with the supplier's dated drawing before release. Record one line per door and photographs of both measurement points. The sheet supports South Africa and East Africa door hardware teams as a fit-control tool, not a compliance statement.

Set up one controlled door record Close the loop with [requesting

Direct answer. Create a unique door ID before measuring. Record the project, city, country, opening use, door-set type

FieldEntryControl
Project and countryProject, city and destinationSeparates fit and clearance evidence
Door IDUnique code and opening labelPreserves every photo and revision
Opening useUnit, communal, staff or serviceConnects the body to the access pattern
Door and frameTimber, steel, glass, aluminium or compositeIdentifies construction-specific fit questions
Door positionLatch side, hinge side and swingSupports handing and strike checks
Drawing sourceSupplier, dated drawing and revisionAnchors all dimensional comparisons

Run the south africa door thickness survey worksheet at the opening

Measure the finished leaf, not the frame stop or nominal board size. Take thickness readings at the latch edge, lock stile and hinge side where access allows. Record each reading and any local build-up rather than selecting the most convenient figure. Use millimetres consistently. If coatings, laminates or an uneven core make the reading uncertain, mark it and attach a close photograph.

Complete the door thickness and backset survey against the supplier's drawing, then define the backset by its datum. The distance from the door edge to the centre of the spindle, cylinder or through-bolt is not interchangeable between products. Record the exact centre used, show the rule in the photograph and transcribe the drawing reference. If the supplier has not defined the datum, leave the field open and issue a hold request.

Treat the backset measurement worksheet as evidence of measurement, not permission to guess. Confirm any permitted range on the dated product page for the specific SKU and its installation drawing; do not infer a tolerance from another model.

Capture the frame and installation context

A correct leaf measurement does not prove a complete fit. Record leaf material, profile, stile and rail width, frame rebate, frame depth, swing direction, handing, existing mortises and the space available for the lock body. Photograph the open door, edge profile and strike area. Where glass or aluminium constrains the body, note the door-set manufacturer and model rather than using a timber-door assumption. Glass and Aluminium Doors in South Africa and East Africa: Smart Lock Fit Constraints provides a separate fit-control route.

If the door is described as fire-rated, capture that description and supporting door-set evidence. Ask the supplier and door-set party how the electronic lock, faceplate, keep and sealing arrangement are handled; do not infer compatibility from leaf thickness alone. Use Fire-rated Doors and Smart Locks in South Africa and East Africa: The Assembly Question for the assembly question.

Apply the fit evidence test

Use each survey status only for dimensional readiness. “Fit ready” means the recorded evidence can support a sample trial; it is not a regulatory pass and does not guarantee site success. Release a survey only when critical dimensions have a named source and every open item has an owner. This is door fit verification, not product approval.

ConditionSurvey statusRequired action
Measurements match the dated drawingREADY FOR TRIALTest the proposed body and keep in the opening
Leaf readings varyHOLD — THICKNESSPhotograph the variance and request a fit decision
Backset datum is missingHOLD — DATUMAsk the supplier to define the measurement centre
Frame or obstruction is absentHOLD — CONTEXTComplete the site record before selection
Critical fields are completeRELEASE TO ORDER REVIEWRecord the approver, evidence set and trial conditions
flowchart TD
  A[Open door record] --> B[Identify door and destination]
  B --> C[Measure leaf thickness]
  C --> D[Measure backset to supplier datum]
  D --> E[Capture frame and installation context]
  E --> F{All critical evidence present}
  F -->|Yes| G[Assign survey status]
  F -->|No| H[Hold and request evidence]
  H --> B
  G --> I[Approve sample or order review]

Record installation and acceptance constraints

Fit evidence becomes commercially weak if field conditions are omitted. In an unstable-grid or load-affected environment, ask whether the intended operating mode must remain battery-first, offline-capable and able to use manual override. This records the project requirement; it does not declare that any model meets it. Ask the installer how service coverage and spares will be supported, how batteries will be replaced at unit turnover, and who will retain the door records. For rental or managed access, state what is included in the total cost per door over the tenancy, including battery changes and turnover.

Security questions should be tied to the opening: what mechanical attack resistance, visible deterrent, anti-snap arrangement or credential workflow is required? Ask for specification or test evidence for the proposed assembly rather than making a generic product claim. Use Smart Lock Installer Practice in South Africa and East Africa: Why Smart Lock Field Reliability Is Really Set There to assign installation checks to the people who will perform them.

Separate fit evidence from clearance evidence

Before commercial release, ask which clearance route applies to the destination and exact SKU: South Africa's LOA/NRCS process, Kenya's PVoC/KEBS route, or another country's route. Demand dated evidence showing its scope and the party that signed it. Store that reference beside the fit record rather than blending geometry and conformity. Use LOA and Pvoc-Style Clearance Evidence for Smart Locks Sold in South Africa and East Africa: A Buyer Document Checklist to keep the evidence sets separate.

CONFIRM-WITH-LOCAL-CONFORMITY: Verify the current route, product scope and sign-off authority for the destination country with the competent local authority or appointed conformity provider, and retain the dated evidence in the project file.

Close the survey with an auditable disposition

End with a release packet: completed worksheet, dated supplier drawing, photographs with IDs, measurement-device note, unresolved-item log, named approver and survey status. For a retrofit, preserve the old lock and frame evidence so the installer can test the proposed body and keep in the actual opening. Add the result to the Smart Lock Retrofit Site Survey. For a business-unit or estate programme, use the Office Smart Lock Site Survey to keep unit, communal and staff-door records consistent.

Readers comparing approaches usually start with smart lock oem marketing materials. That is the same question south africa door thickness survey worksheet has to answer here.Approve a sample trial where READY FOR TRIAL and RELEASE TO ORDER REVIEW matter. Ask the supplier to confirm on the dated product page for the specific SKU which dimensions and installation conditions apply. Record every change as a revision, then issue a replacement door record rather than obscuring what was known at approval.

The quote request is where the decision turns into a number: request a quote.