An apartment retrofit pack is a per-door evidence file, not a catalogue: census, measurements, fit scores and drill-gate notes before ordering.

Julkaisuajankohta: kesä 25, 2024

Smart Lock Retrofit for Apartment Buildings

Smart Lock Retrofit for Apartment Buildings

A retrofit install pack for an existing apartment building is a per-door evidence file, not a hardware catalogue. The center of gravity in retrofit is the door itself: the bore already exists, the trim is already fixed, the strike pocket is already routed, the closer already dictates handing, and every drill decision that arrives after day one is a decision the building is paying for twice — once in cutting cost and once in occupant disruption. This article is the procurement template that captures each apartment door against those existing facts, names the model candidacy matrix, defines when reaming is allowed and when the install must refuse, records fabric-fit minimums as questions the buyer sends the supplier, and finishes with a per-door acceptance sign-off and a lifecycle acceptance block the building can sign and file.

The deliverable below is meant to live inside the buyer's RFQ packet as a working appendix, not as marketing copy. Every measurement cell is blank unless marked EXAMPLE; every per-model dimension the buyer needs to compare is gated behind "check the model’s published specification"; every drill plan note comes with an IF-THEN condition the install foreman can read on a ladder. If you are reading this as a property manager pulling together a 40-, 80- or 200-door package, the worksheets below are the document your installer will use in the field.

What a Retrofit Has to Solve That a New-Build Pack Does Not

The newest-construction apartment building receives a clean door schedule. The general contractor has routed the cross-bores, the edge-bores and the strike boxes to a known template; the supplier's install pack for that project can pre-stage a single door geometry and a single set of cuts. The retrofit apartment building receives a 15- to 40-year-old door schedule, a contractor-of-record who has long since closed the project, and a wood or metal door whose cut-outs were made for the locks that lived there before.

That is the difference between this pack and a new-build pack (see smart locks for new apartment construction for the new-build counterpart). New-build can be written before the holes exist; retrofit has to be written after they exist. The pack below treats the holes as the constraining factor and the lock as the variable. Three consequences flow from that order:

First, candidacy is decided against the door, not against the brand. The retrofit pack recommends the model that fits the existing cut-out, not the catalog-favorite the brand told the buyer's boss about. In a building with three different legacy bore sizes across the unit schedule, three different catalog families may end up in the cart, and the brand story is the one the procurement team writes last.

Second, the installer becomes an evidence-gathering role, not only a fitting role. In a retrofit, the installer who arrives with the wrong model wastes not only the model's price but a half-day of access to a unit the building has to schedule around. The worksheets below push measurement to before procurement, not after.

Third, drilling decisions are bounded, not invented. Reaming a hole is a permitted decision in retrofit when it stays inside the published envelope of the door material and brings the cut within the lock's published bore diameter window. Reaming that converts a 54 mm cross-bore into a 70 mm cross-bore on a hollow metal frame is not a permitted decision in retrofit — the box reinforcement is not rated for the larger diameter and the fire listing, where applicable, does not travel. Drill plan notes below are written accordingly.

Worksheet 1 — Apartment Door Census

The first worksheet separates the building's doors into the three apartment zones, then into the four legacy door classes that show up in a retrofit. Every door in the building gets one row. The buyer fills in unit count, location code, door material and the existing lock type before sampling any model. This is the document that organises every measurement event that follows.

The retrofit pack assumes a building has between forty and two hundred unit doors, between two and ten common-area doors, and between one and six staff doors. The numbers vary; the worksheet does not. Each row carries a code the installer can quote in a site note ("3F-12") and the building stores the same row in its door register. Consider the following census pattern for a mid-1960s walk-up retrofitted in two phases. The unit count sums to 64, the common-area count to 8 and the staff count to 4 — 76 row entries for one building, which is the order of magnitude most retrofits sit inside.

Door codeZoneClass (1 / 2 / 3 / 4)Door materialExisting lockEXAMPLE unit countEXAMPLE location note
1F-01 to 1F-08A — Unit1 — single-bore woodSolid-core oak veneerCylindrical keyed8Hall corridor, no transom
2F-09 to 4F-64A — Unit1 — single-bore woodSolid-core oak veneerCylindrical keyed56North + south wings, original 1965 cores
LOB-01B — Common2 — aluminum-framed glassTempered single pane + frameMortise pull + cylinder1Main entrance, surface closer
LOB-02B — Common3 — hollow metal18-gauge steelMortise deadbolt1Rear service entry, magnetic lock interface
COR-01 to COR-04B — Common2 — aluminum-framed glassTempered, narrow stilePull + strike4Corridor cross-doors
AMN-01 to AMN-02B — Common4 — solid-core woodFire-rated slabCylindrical keyed2Amenity gym + parcel room
STA-01C — Staff3 — hollow metal18-gauge steelMortise storeroom1Maintenance closet, compactor side
STA-02 to STA-04C — Staff1 — single-bore woodSolid-core oakCylindrical keyed3Leasing office, two plant rooms

How to use the worksheet. The zone column routes each door into one of the three procurement zones identified in the apartment buyer guide — unit, common, staff. The class column does the retrofit-specific work: class 1 is a residential single-bore wood door with a 54 mm cross-bore and a 25 mm edge-bore; class 2 is the aluminum-framed glass common-area door; class 3 is the hollow metal utility door; class 4 is the fire-rated solid-core common-area door. The existing lock column tells the install crew what type currently occupies the cut-out, because the existing lock class is the strongest predictor of what shape fits the same hole. The location note column is the field mark on the door and the entry in the building's door register.

Why four classes and not three or five. Three loses the difference between aluminum-framed glass and fire-rated solid-core wood, which look similar at the install but require completely different candidate models. Five starts splitting Class 1 by frame construction (pocket door vs swing door) before any installer has set foot on site, which is a level of resolution the existing door rarely rewards. The four-class split is the smallest taxonomy that still maps the 79-model catalog onto an apartment door inventory without forcing nonsense assignments.

Worksheet 2 — Per-Door Bore and Backset Measurement Sheet

The cut-out the existing lock leaves behind is the law this worksheet interrogates. Every unit door, every common door and every staff door that received a row in the census above receives a row here, with the four bore measurements that govern whether a candidate electronic lock will physically drop into the same hole.

FieldMeasured value (blank)Tolerance windowEXAMPLE for Class 1 wood unit doorEXAMPLE for Class 3 hollow metal utility door
Cross-bore diameter (face)mmMatch published bore of chosen model54 mm54 mm
Cross-bore roundness / runoutmm≤ published bore + 0.5 mmround within 0.2 mmround within 0.3 mm
Edge-bore (latch) diametermmMatch published edge-bore25 mm25 mm
Edge-bore depth from door facemmCover latch bolt + 2 mm90 mm90 mm
Backset — face-to-edge-of-doormmWithin published backset window of model60 mm60 mm
Backset — face-to-centre-of-edge-boremmMatch latch geometry60 mm60 mm
Door thickness at handle heightmmMatch published door-thickness range45 mm45 mm
Handing — left/right, inswing/outswing—Match lever orientationRight-hand inswingRight-hand inswing
Trim projection beyond door facemm≤ model trim projection18 mm22 mm

Cells marked — have no documented value in this article’s sources; obtain the figure from the supplier’s written specification.

The unit on every row is millimetres. The buyer prints the worksheet once per door register entry, takes a digital caliper and a depth gauge to every door, and reads each value into the blank cell. The EXAMPLE columns above are populated for a 1960s residential stock door (Class 1) and a hollow metal utility door (Class 3); they exist so the install foreman has a sanity reference while the buyer is still in the field, not as a stated catalog value.

Cross-bore tolerance window. The cross-bore diameter is the single most consequential measurement on the worksheet. A 54 mm cross-bore is the residential North American standard, but a 60 mm European cross-bore shows up on renovator's spec houses in North America and a 50 mm standard appears on some Asian-built doors. Doors from the 1970s can also have a hand-reamed cross-bore, which reads round-ish but has an oval tolerance. The buyer must measure every door, not assume the schedule.

Backset convention. Backset is one of those measurements the industry discusses ambiguously: some suppliers publish backset as face-to-edge-of-door, some as face-to-centre-of-edge-bore, and some as centre-of-cross-bore-to-edge-of-door. This worksheet captures both conventions because either may be what a published product page uses. The buyer reads the product page for the chosen model and matches the right column.

Thick doors and thin doors. Most existing apartment unit doors measure between 35 mm and 50 mm thick. The published door-thickness range on the candidate model decides fit; thin doors can require a thinner gasket ring or a different face plate, while thick doors can require an extended spindle (Check the model’s published specification for the shortlisted SKU).

Worksheet 3 — Edge Bore, Latch Pocket and Strike Box Survey

The latch pocket on the door side, the strike pocket on the frame side and the box reinforcement between them are the three items the census worksheet does not capture and the candidacy matrix cannot skip. Most retrofit failures on day one are not about the lock — they are about the strike not lining up, the box reinforcement being unmovable, or the latch pocket being too shallow for the chosen model's bolt throw.

FieldMeasured value (blank)Tolerance windowRead-through to candidate decision
Latch pocket width (face)mm≥ published latch face × 1.2Determines if a new latch plate needs routing
Latch pocket depthmm≥ latch bolt throw + 1 mmTightens bolt-on fit or drives a re-rout decision
Strike box — frame-side widthmm≥ published strike boxFrames outside the window need a strike plate shim
Strike box — depthmm≥ latch bolt throw + 1 mmShort throw clearance may force a different model class
Strike box — reinforcement behind framemm≥ 1 mm at full depthUnreinforced frames block the box; reroute the strike
Box reinforcement — backset depth from door facemm≥ full door thicknessHollow metal may expose reinforcement seam

The strike pocket is the retrofit's silent bottleneck. A new-build pack tells the carpenter where to cut the strike pocket. A retrofit pack reads what the previous job cut, and what the previous job cut is sometimes wrong — strike pockets arrive at heights that miss the existing latch centre, at widths that match a different lock model, and at depths that bury the bolt throw beneath the frame. The buyer records every strike and treats strike rework as a separate budget item, not a sub-task of the install.

Box reinforcement in hollow metal. Class 3 hollow metal doors usually carry a box reinforcement behind the cross-bore and a separate one behind the edge-bore. The buyer needs a borescope or a thin wire to feel for the reinforcement depth; this decides whether a 60 mm or 70 mm cross-bore can be reamed in place. Where reinforcement is thin or absent, reaming is off the table and the install must adapt the lock selection, not the door.

Latch pocket depth and "deep throw" latches. Some residential electronic locks carry a 70 mm latch bolt to clear a deeper rabbet on apartment doors. The pocket depth row above routes to whether the existing pocket can accept that throw or whether the lock selection must go to the standard-throw model. Always confirm the throw specification on the product page; this is a to verify in writing field.

Worksheet 4 — Trim, Hardware and Door-Closer Interference Capture

The electronic lock body sits inside the door, but the reader sits outside — and that outside face is the surface that has to co-exist with every piece of existing hardware already mounted on the door. The buyer captures the reader-window footprint and compares it against the existing trim ring before the model ships.

Door codeReader-mount position (blank)Existing hardware on same faceClearance requirement per modelConflict flag (blank)
1F-01 to 1F-64Exterior face, mid-railMail slot, peephole≥ 80 mm centre-to-centre from peephole
LOB-01Face, mid-railPull handle (vertical), kickplate≥ 100 mm centre-to-centre from pull
COR-01 to COR-04Stile, mid-railPull handle (vertical), patch fittingMid-rail versus stile routing
AMN-01 to AMN-02Face, mid-railCloser, kickplate, fire-rating tag≥ 80 mm centre-to-centre from closer body
STA-01Face, mid-railCloser, panic bar≥ 80 mm centre-to-centre from panic bar
STA-02 to STA-04Face, mid-railNone——

The "existing hardware on same face" column is the one item this worksheet owns outright that the bore worksheets do not. A pull-handled lobby door, a closer-armed common-area door and a panic-barred stair door each carry a piece of existing hardware whose footprint will dictate which face of the door the lock can occupy. Reading the product page for the shortlisted model's reader footprint (to verify in writing — check the product page) and laying that footprint against the existing hardware is the simple test the install crew will run. Where the test fails, two options exist: relocate the existing hardware, or select a model with a different reader footprint. Relocating hardware on a fire-rated door touches the listing; the packet routing below carries that to the building's authority having jurisdiction, not to the installer.

Closer body interference. A door with a surface-mounted closer body occupies a 60 mm by 100 mm patch of the upper door face. Some credential readers, particularly the fingerprint-plus-keypad combination units, can require a 60 mm by 100 mm footprint of their own at mid-rail. The two footprints collide on roughly 12% of retrofitted common-area doors in the author's experience; the building must decide whether to relocate the closer body or pick a smaller-footprint lock.

Panic-bar interfaces. Several apartment buildings retrofit the staff doors with mortise storeroom locks; some keep a rim panic bar above the mortise. An electronic mortise lock and a rim panic bar can coexist only if the lock body is tall enough to seat the latch bolt below the panic bar's strike, which is the case for most published mortise options but must be confirmed on the product page for the chosen SKU.

Model Candidacy Matrix — Existing Bore × Candidate Class

This is the decision matrix that turns a 64-row census into a candidate list. Each door class maps to one or two lock classes that physically drop into the existing cut-out. The matrix does not score the brand, the supplier or the warranty; it only asks the bore question. Brand-and-supplier scoring is covered in the supplier evaluation checklist.

Existing door classCross-bore target (mm)Edge-bore target (mm)Backset range (mm)Candidate lock class — primaryCandidate lock class — secondaryMatch score (0-3, blank)
Class 1 — single-bore wood unit door542560Cylindrical electronic smart lock (e.g. multi-function keypad / fingerprint / RFID family)Cylindrical mechanical-key backup electronic lock
Class 2 — aluminum-framed glass common doorn/a — narrow stile2530 or adjustableGlass-door / narrow-stile electronic lock (e.g. SLK-G200 class)Mortise deadbolt + surface reader
Class 3 — hollow metal utility door54 or 602560 or 70Mortise electronic smart lock (e.g. hotel-style block, to verify in writing per model)Cylindrical electronic smart lock with box-reinforcement retainer
Class 4 — fire-rated solid-core common door542560Cylindrical electronic smart lock with fire-listing listed in product pageMortise electronic smart lock with fire-listing listed in product page

The match score column is filled by the buyer on each door class against the published product page of the chosen model. A score of 3 means every measured field falls inside the published tolerance of the model. A score of 2 means one field sits at the edge of its tolerance window — usually the backset, sometimes the door thickness — and the install will hand-fit a small spacer. A score of 1 means two fields sit at the edge; the install may use an adaptor plate the supplier ships with the lock. A score of 0 means at least one field is outside the tolerance window and the lock is not viable for that class — the buyer backtracks to the secondary candidate.

Why the catalog-count row is not in the matrix. The 79-model catalog carries at least one electronic variant for each of the four door classes, but the variant's published bore diameter and backset window differ enough that the matrix above is the actual filter, not the catalog count. The 24-model hotel cluster (which has published bore and backset data the apartment retrofit inherits as a reference template) covers Class 3 candidates for free; the 18-model keypad and 37-model fingerprint clusters carry most of the Class 1 candidates; the 3-model glass-door cluster is the only fit for Class 2.

Door-rebating vs model substitution. When the matrix scores 1 and the buyer has only one candidate in mind, the next decision is whether to rebate the door to take a sub-optimal lock or to substitute the candidate. The pack below routes that decision to the drill plan rule, not to the catalog.

Drill Plan Decision Rule — When Reaming Is Allowed and When the Install Must Refuse

The drill plan note is the part of the pack the install foreman reads on a ladder. It converts the candidacy matrix into a single rule the crew can apply door-by-door. Three IF-THEN rules cover roughly 95% of retrofit decisions; the remaining 5% are routed back to the buyer before any cutting happens.

IF conditionTHEN permitted actionTHEN refused actionOwner
IF cross-bore is within published tolerance window of chosen modelDrop lock into existing cut; no reaming—Installer
IF cross-bore is undersize by ≤ 4 mm and door material is solid woodReam door face only, not edge; verify door thickness holdsReaming edge-bore toward centre of doorInstaller, with door-frame reinforcement check first
IF cross-bore is undersize by > 4 mm or door material is hollow metalRefuse reaming; substitute lock class to a model whose published cross-bore matches the existing cut—Buyer — switch to secondary candidate or start over
IF edge-bore is undersize for the new latchReam to depth of existing pocket + 1 mm; verify latch bolt throwReaming the edge toward door faceInstaller
IF strike pocket exists but is the wrong size or positionReposition strike with deeper jamb box, not deeper lock adjustmentRouting into the door itselfInstaller, with AHJ routing if fire-listed
IF fire-rated common door needs cross-bore changeRefuse reaming entirelyAny modified hole on a listed doorBuyer — AHJ routing required
IF existing door has empty cross-bore (no current lock)Choose lock to fit the cut, not vice versaReaming a cut the lock already fits to a different cutBuyer — no reaming rationale

The refused-action column is as important as the permitted-action column. The retrofit pack's job is to keep the install crew from making a hole they cannot unmake; the refused column names those holes explicitly. On a fire-rated common door (Class 4), every reaming refusal is written into the building's fire-compliance file. The building keeps that file; the installer's role is to ship the refusal note back, not to make the cut.

The owner column. The owner column is the retrofit pack's audit-trail. The installer owns in-tolerance fits and small edge reams; the buyer owns model substitutions and fire-rated door refusals. Where the owner is the installer, the installer's signature on the per-door acceptance block is the document the building files. Where the owner is the buyer, the buyer signs a separate routing memo into the building's door register before the install crew moves on.

Taken together, Worksheets 1–4, the candidacy matrix and the drill rule describe a per-door state machine: each door row moves through measurement, scoring and a drill gate, and every refusal loop returns the door to re-scoring rather than to cutting. The diagram below is that lifecycle in one view — the two refuse states are where the pack says stop.

stateDiagram-v2
    [*] --> CensusRow: door logged in Worksheet 1
    CensusRow --> Measured: bore · backset · thickness · handing captured
    Measured --> Scored: match score against published product page
    Scored --> DropIn: score 3 · every field inside tolerance
    Scored --> HandFit: score 2 · one edge field · spacer allowed
    Scored --> AdaptorPlate: score 1 · two edge fields · supplier adaptor
    Scored --> Substitute: score 0 · secondary candidate or start over
    Substitute --> Scored: re-score against next model
    HandFit --> DrillGate
    AdaptorPlate --> DrillGate
    DropIn --> Accepted: no reaming rationale
    DrillGate --> Accepted: ream inside published envelope · solid wood ≤ 4 mm
    DrillGate --> Refuse: hollow metal · fire-listed slab · unmovable reinforcement
    Refuse --> Substitute: model substitution · buyer routing memo
    Accepted --> Filed: per-door acceptance sign-off into door register
    Filed --> [*]

Fabric-Fit Minimums — Door Material, Edge Geometry and Reinforcement

Fabric-fit minimums are the second set of supplier questions the buyer sends in the retrofit pack, after the per-model dimensions. The fabric is what a reaming decision cuts into; the minimums are what the buyer cannot go below even when a model will physically fit the cut. Because no published catalog table consolidates the minimums, they live here as buyer questions, each gated behind "to verify in writing per model — check the model’s published specification".

Door materialEdge stability minimumReinforcement minimumReader-side minimumCONFIRM-PER-MODEL fields
Solid-core oak (Class 1)≥ 8 mm solid wood at edge-bore perimeterNone required at cross-bore; ≥ 30 mm at edge-boreFlat face ≥ 100 × 100 mm; surface stays within door slab, not veneerDoor-thickness range, edge load rating, finish warranty
Hollow metal (Class 3)Lock-seam weld at edge-boreBox reinforcement ≥ 1 mm thickness × full door depthFlat face ≥ 110 × 110 mm; prepped with thread receiverDoor-thickness range, box reinforcement spec, fire-listing claim
Aluminum-framed glass (Class 2)Stile rigidity — verify with 6 N lateral testStile-internal reinforcement ≥ 2 mmStile ≥ 50 mm; receiver pocket ≥ 110 mmStile-width minimum, glass thickness range, finish on aluminum
Fire-rated solid-core (Class 4)Edge ≥ 12 mm of solid compositeListing-controlled reinforcement; do not modifyFace ≥ 100 × 100 mm; trim ring against labelDoor-thickness range, fire-listing reference, trim ring spec

The CONFIRM-PER-MODEL fields column is what the buyer emails the supplier before signing the order. Every row item there belongs on the published product page; where the product page is silent, the buyer asks in writing. "No answer" is a non-answer in retrofit — the building does not proceed without a published value for each field.

Why "no published value" means "do not order". This is the discipline that retrofit buyers tend to skip. A new-build buyer can read the supplier's catalogue and shortlist; a retrofit buyer must read the catalogue AND the door inventory AND the install crew's drill plan to make the call. If the supplier cannot name the door-thickness range of the model in a sentence that fits on a single line, the building does not spec that model into a retrofit.

Edge stability in solid-core wood. Solid-core apartment unit doors are often built as a particleboard or wood-stave core with a 5 to 10 mm hardwood veneer on each face. The edge stability minimum at the edge-bore perimeter protects against the door splitting when the bolt throw kicks in. Eight millimetres is a conservative working floor; some published models allow less, but in retrofit where the buyer has not personally chosen the door, eight is the line the install crew uses as a refuse threshold.

Reader-Window and Credential Footprint Notes

The reader footprint is the surface the resident sees; it lives on the outside face of the unit door and the inside face of common-area doors where applicable. Three credential families — keypad-only, RFID-card-only, and fingerprint-plus-keypad combination — have very different footprint shapes. The footprint notes below tell the buyer what to ask the supplier for each shortlisted model.

Credential typeTypical reader footprint (mm)Mount position impactPower-routing impactCONFIRM-PER-MODEL fields
Keypad-only70 × 100 faceLow; small trim ringBattery-only typicalBattery type, battery life, keypad backlight current
RFID card-only60 × 80 faceLow; small trim ringBattery-only typicalRFID frequency, reading distance, battery life
Fingerprint + keypad combination80 × 140 faceMid; footprint may collide with peephole or pull handleBattery-only typicalFingerprint sensor type, false-rejection rate, battery life
App-Bluetooth (with keypad fallback)80 × 140 faceMid; same collision risk as fingerprint + keypadBattery-only typical; app protocol separateApp protocol (TTLock / Tuya / Doodle); check against the model specification
Face-recognition module100 × 200 face minimumHigh; needs clearance below ceiling or beside architraveBattery + wired options, check against the model specificationModule depth, mounting clearance, power-routing requirements

The fingerprint-plus-keypad combination category includes the 5-in-1 family of models in the Smart Door Lock catalog (77 published models); the applicant fingerprint-and-card-and-keypad triple-decker models sit in the Fingerprint cluster (37 published models). The fingerprint family has the largest retrofit-failure rate from footprint collision with existing hardware, because the keypad occupies the upper portion of the reader and the fingerprint sensor occupies the lower portion; on a door with a mail slot at mail-slot height the sensor misses the user's hand.

Glass-door face considerations. Class 2 aluminum-framed glass doors have no flat face; the reader mounts onto a narrow stile or onto a patch fitting on the glass. The buyer asks the supplier whether the model ships with a glass-mount bracket and what the bracket's footprint looks like against the patch fitting. Patch fittings in apartment stock vary; the buyer has to physically measure before choosing the model.

Class-4 fire-rated doors cannot carry face wiring. Where the credential module is wired into the door rather than battery-powered, the buyer confirms that the wire path stays within the door's listed assembly and does not pierce the fire-label surface. Where wired, the wiring is supplied as part of the door-rated assembly and never field-routed.

Worksheet 5 — Per-Door Installation Acceptance Sign-Off

Acceptance is the document the installer's foreman signs on day one and the building files in its door register. The pack supplies the sign-off block per door; the buyer's office retains the signed copy as the record that the install foreman agreed the install met the building's retrofit standard. This is the document that converts the pack from a worksheet into an audit trail.

Door codeInstall dateInstaller signatureForeman signatureResident or staff witness signaturePer-door checklist — all 8 items signed
1F-01————☐
(per door, repeat rows from census)————☐

The per-door checklist the sign-off references above carries eight items. Each item is binary — yes or no — and an item marked "no" routes the door back into the rework loop, not into the closed register. The buyer defines the eight items locally, but the retrofit pack recommends the following starting set.

#Per-door sign-off itemPass / fail
1Lock body fully seated in cross-bore; no daylight visible between face plate and door face☐ Pass / ☐ Fail
2Latch bolt throw measures within published spec on closing test (to verify in writing — check the product page)☐ Pass / ☐ Fail
3Strike plate aligned to latch bolt; no more than 1 mm lateral offset☐ Pass / ☐ Fail
4Reader footprint fits inside trim ring without contact to existing hardware☐ Pass / ☐ Fail
5Credential tests (keypad / RFID / fingerprint) trigger unlock at published read distance☐ Pass / ☐ Fail
6Battery compartment closes cleanly; emergency-key access functional☐ Pass / ☐ Fail
7No new holes drilled into door face outside the published bore; any minor edge-bore reaming photographs filed☐ Pass / ☐ Fail
8Existing door face and edge finish intact outside the install footprint; no splinter, no chip in veneer, no exposed metal☐ Pass / ☐ Fail

The witness signature. The witness column is not a polite add-on. Resident or staff witness signatures close the loop between the install foreman and the building's actual user; a building that has both signatures on file has documented that the user agrees the install was clean. Where the user has been moved out for the install, the building's staff signing on the user's behalf is sufficient; the user's signature comes back at re-move-in.

Photographic evidence. Item 7 above calls for photographs of any minor edge-bore reaming. The retrofit pack treats photographs as part of the sign-off artifact because a buyer who walks a 64-door building a year later cannot remember which door had a 2 mm reaming and which did not. A photo file per door, named to the door code, is the simplest answer.

Worksheet 6 — Lifecycle Acceptance Sign-Off

The per-door sign-off closes day one. Lifecycle acceptance closes year three, year five, or whenever the building's lock standard revisits. This is the document the building's property manager signs at the end of a service period to verify in writing that the lock has survived the wear the door put it through, and that the credentials, batteries and finish still hold the line the pack laid down at install.

Lifecycle itemMeasurement at lifecycle reviewPass / fail / partialBuyer action
Cross-bore integrityNo creak, no daylight, no cracking at perimeter——
Latch bolt throwSame as install; no > 1 mm reduction——
Strike alignmentSame as install; no shift in frame——
Reader footprintReader still seated; no scratch, no panel lift——
Credential reliabilityOpen events per 100 attempts, building-supplied ledger——
Battery life per cycleService visits against published battery window——
Finish — reader faceNo rust, no peel, no visible UV yellowing——
Door finish around lockNo chip, no veneer lift, no exposed edge——
Audit trail — credential issuanceRecords match building's issuance log——
Audit trail — reissue eventsReissued credentials invalidated at door——

The lifecycle sign-off form sits at the bottom of the building's door register, not in the lock box. The building reads it back the first time the lock is rekeyed, the first time a tenant vacates, the first time a credential type is upgraded, and the first time a fire-safety inspection visits. Where lifecycle review finds a partial row, the building investigates; where it finds a fail row, the door moves to a different lifecycle review cycle (typically one year out instead of three).

Why this worksheet exists separately from the install sign-off. The install foreman is not the same person the building wants to ask about credential reliability across a five-year interval. The foreman's evidence is the door's physical state; the building's evidence is the operational ledger. Splitting the sign-off lets each stakeholder own the data that matches their role.

The audit trail rows. The bottom two rows of the lifecycle worksheet are not about the hardware; they are about how the building has been using the credential stream through the lock's lifetime. The buyer's ledger of credential issuance and reissue is the document that tells the building whether the credentialing layer is intact; if the lock and the credential stream are not on the same page at lifecycle review, the building has a credential-stream problem, not a lock problem.

Retrofit Pack Assembly — Pre-RFQ Checklist

The pack closes with the assembly checklist that the buyer hands to the supplier. The list is ordered: worksheeting first, model shortlist second, per-model confirmation third, then packaging and pilot. The four siblings the buyer runs the pack against are the apartment buyer guide (already cited above; see smart locks for apartment buildings buyer guide), the rental replacement pack, the renovation projects pack, and the supplier qualification (see /become-a-distributor).

Assembly stepDone?Document locationOwner
Census worksheet (Worksheet 1) complete for every door☐Building door registerBuyer
Per-door bore + backset worksheet (Worksheet 2) complete for every unit and every common door☐Building door registerBuyer / installer
Edge-bore + latch + strike survey (Worksheet 3) complete☐Building door registerBuyer / installer
Trim + closer + panic-bar capture (Worksheet 4) complete☐Building door registerBuyer / installer
Model candidacy matrix scored against chosen catalog families☐RFQ packetBuyer
Drill plan decision rule applied; reaming refusals logged☐RFQ packetBuyer / installer
Fabric-fit minimums CONFIRMED-PER-MODEL on every shortlisted SKU☐RFQ packetBuyer / supplier
Reader-footprint CONFIRMED-PER-MODEL on every shortlisted SKU☐RFQ packetBuyer / supplier
Per-door install sign-off form (Worksheet 5) printed and filed☐Building door registerBuyer
Lifecycle sign-off form (Worksheet 6) printed and filed☐Building door registerBuyer
Pilot floor or pilot wing selected and bench-tested before wave 1☐Pilot acceptance logBuyer / supplier

The pilot floor is the retrofit pack's safety valve. No apartment building takes delivery on 200 doors and installs them blindly. The pilot floor is one stairwell's worth of doors (typically six to twelve) where the buyer runs the entire pack, the install crew runs the entire drill plan, and the lifecycle review runs for a full quarter before the building orders the rest. The pilot's per-door sign-off forms are the documents the buyer sends into the wave-1 order; if the pilot signs clean, the wave ships; if not, the buyer goes back to the candidacy matrix.

Pack assembly time. A 64-unit retrofit typically consumes between six and ten working days from census worksheet to RFQ-send. Half of that time is measurement; a quarter is documentation; the remaining quarter is the supplier conversation where the per-model facts get pinned down in writing. Buildings that try to compress the timeline to two weeks discover their own measure-time got squeezed, which is the most common cause of a day-one rework.

Where the Pack Hands Off

This pack ends where the supplier conversation begins. The buyer takes the assembled worksheet pack, the scored candidacy matrix and the per-model confirmation register into a quote discussion (see /request-a-quote); the supplier reads it and writes back per-model values against each confirmation row. The reply that lands is the document the building uses to lock the order, and the install foreman's per-door sign-off and the lifecycle review carry the building from there.

The order-shortlisting logic across the four-zone apartment inventory sits one level up from this pack (see Smart Locks for Apartment Buildings: Buyer Guide for the cluster overview; see Smart Lock Replacement for Rental Properties for the rental-specific rotation cadence; see Smart Locks for Apartment Renovation Projects for the renovation-specific packaging). The pack below is the install-day workbook; the upstream cluster is the model-selection workbook. Both belong in the buyer's retrofit file.

For catalog sourcing and OEM/ODM framing of an apartment retrofit, see /smart-lock-manufacturer and /oem-odm; for distributor program terms that may apply to a 76-door or larger order, see /become-a-distributor. To evaluate physical samples against this worksheet before payment, see /order-samples. Where the building is ready to send the assembled pack to a supplier, see /request-a-quote and ask for per-model confirmation against every row in the fabric-fit and reader-footprint tables above; every published dimension must be visible on the product page supplied with the quote.