Smart Lock Retrofit for Apartment Buildings
A retrofit install pack for an existing apartment building is a per-door evidence file, not a hardware catalogue. The center of gravity in retrofit is the door itself: the bore already exists, the trim is already fixed, the strike pocket is already routed, the closer already dictates handing, and every drill decision that arrives after day one is a decision the building is paying for twice — once in cutting cost and once in occupant disruption. This article is the procurement template that captures each apartment door against those existing facts, names the model candidacy matrix, defines when reaming is allowed and when the install must refuse, records fabric-fit minimums as questions the buyer sends the supplier, and finishes with a per-door acceptance sign-off and a lifecycle acceptance block the building can sign and file.
The deliverable below is meant to live inside the buyer's RFQ packet as a working appendix, not as marketing copy. Every measurement cell is blank unless marked EXAMPLE; every per-model dimension the buyer needs to compare is gated behind "check the model’s published specification"; every drill plan note comes with an IF-THEN condition the install foreman can read on a ladder. If you are reading this as a property manager pulling together a 40-, 80- or 200-door package, the worksheets below are the document your installer will use in the field.
What a Retrofit Has to Solve That a New-Build Pack Does Not
The newest-construction apartment building receives a clean door schedule. The general contractor has routed the cross-bores, the edge-bores and the strike boxes to a known template; the supplier's install pack for that project can pre-stage a single door geometry and a single set of cuts. The retrofit apartment building receives a 15- to 40-year-old door schedule, a contractor-of-record who has long since closed the project, and a wood or metal door whose cut-outs were made for the locks that lived there before.
That is the difference between this pack and a new-build pack (see smart locks for new apartment construction for the new-build counterpart). New-build can be written before the holes exist; retrofit has to be written after they exist. The pack below treats the holes as the constraining factor and the lock as the variable. Three consequences flow from that order:
First, candidacy is decided against the door, not against the brand. The retrofit pack recommends the model that fits the existing cut-out, not the catalog-favorite the brand told the buyer's boss about. In a building with three different legacy bore sizes across the unit schedule, three different catalog families may end up in the cart, and the brand story is the one the procurement team writes last.
Second, the installer becomes an evidence-gathering role, not only a fitting role. In a retrofit, the installer who arrives with the wrong model wastes not only the model's price but a half-day of access to a unit the building has to schedule around. The worksheets below push measurement to before procurement, not after.
Third, drilling decisions are bounded, not invented. Reaming a hole is a permitted decision in retrofit when it stays inside the published envelope of the door material and brings the cut within the lock's published bore diameter window. Reaming that converts a 54 mm cross-bore into a 70 mm cross-bore on a hollow metal frame is not a permitted decision in retrofit — the box reinforcement is not rated for the larger diameter and the fire listing, where applicable, does not travel. Drill plan notes below are written accordingly.
Worksheet 1 — Apartment Door Census
The first worksheet separates the building's doors into the three apartment zones, then into the four legacy door classes that show up in a retrofit. Every door in the building gets one row. The buyer fills in unit count, location code, door material and the existing lock type before sampling any model. This is the document that organises every measurement event that follows.
The retrofit pack assumes a building has between forty and two hundred unit doors, between two and ten common-area doors, and between one and six staff doors. The numbers vary; the worksheet does not. Each row carries a code the installer can quote in a site note ("3F-12") and the building stores the same row in its door register. Consider the following census pattern for a mid-1960s walk-up retrofitted in two phases. The unit count sums to 64, the common-area count to 8 and the staff count to 4 — 76 row entries for one building, which is the order of magnitude most retrofits sit inside.
| Door code | Zone | Class (1 / 2 / 3 / 4) | Door material | Existing lock | EXAMPLE unit count | EXAMPLE location note |
|---|---|---|---|---|---|---|
| 1F-01 to 1F-08 | A — Unit | 1 — single-bore wood | Solid-core oak veneer | Cylindrical keyed | 8 | Hall corridor, no transom |
| 2F-09 to 4F-64 | A — Unit | 1 — single-bore wood | Solid-core oak veneer | Cylindrical keyed | 56 | North + south wings, original 1965 cores |
| LOB-01 | B — Common | 2 — aluminum-framed glass | Tempered single pane + frame | Mortise pull + cylinder | 1 | Main entrance, surface closer |
| LOB-02 | B — Common | 3 — hollow metal | 18-gauge steel | Mortise deadbolt | 1 | Rear service entry, magnetic lock interface |
| COR-01 to COR-04 | B — Common | 2 — aluminum-framed glass | Tempered, narrow stile | Pull + strike | 4 | Corridor cross-doors |
| AMN-01 to AMN-02 | B — Common | 4 — solid-core wood | Fire-rated slab | Cylindrical keyed | 2 | Amenity gym + parcel room |
| STA-01 | C — Staff | 3 — hollow metal | 18-gauge steel | Mortise storeroom | 1 | Maintenance closet, compactor side |
| STA-02 to STA-04 | C — Staff | 1 — single-bore wood | Solid-core oak | Cylindrical keyed | 3 | Leasing office, two plant rooms |
How to use the worksheet. The zone column routes each door into one of the three procurement zones identified in the apartment buyer guide — unit, common, staff. The class column does the retrofit-specific work: class 1 is a residential single-bore wood door with a 54 mm cross-bore and a 25 mm edge-bore; class 2 is the aluminum-framed glass common-area door; class 3 is the hollow metal utility door; class 4 is the fire-rated solid-core common-area door. The existing lock column tells the install crew what type currently occupies the cut-out, because the existing lock class is the strongest predictor of what shape fits the same hole. The location note column is the field mark on the door and the entry in the building's door register.
Why four classes and not three or five. Three loses the difference between aluminum-framed glass and fire-rated solid-core wood, which look similar at the install but require completely different candidate models. Five starts splitting Class 1 by frame construction (pocket door vs swing door) before any installer has set foot on site, which is a level of resolution the existing door rarely rewards. The four-class split is the smallest taxonomy that still maps the 79-model catalog onto an apartment door inventory without forcing nonsense assignments.
Worksheet 2 — Per-Door Bore and Backset Measurement Sheet
The cut-out the existing lock leaves behind is the law this worksheet interrogates. Every unit door, every common door and every staff door that received a row in the census above receives a row here, with the four bore measurements that govern whether a candidate electronic lock will physically drop into the same hole.
| Field | Measured value (blank) | Tolerance window | EXAMPLE for Class 1 wood unit door | EXAMPLE for Class 3 hollow metal utility door |
|---|---|---|---|---|
| Cross-bore diameter (face) | mm | Match published bore of chosen model | 54 mm | 54 mm |
| Cross-bore roundness / runout | mm | ≤ published bore + 0.5 mm | round within 0.2 mm | round within 0.3 mm |
| Edge-bore (latch) diameter | mm | Match published edge-bore | 25 mm | 25 mm |
| Edge-bore depth from door face | mm | Cover latch bolt + 2 mm | 90 mm | 90 mm |
| Backset — face-to-edge-of-door | mm | Within published backset window of model | 60 mm | 60 mm |
| Backset — face-to-centre-of-edge-bore | mm | Match latch geometry | 60 mm | 60 mm |
| Door thickness at handle height | mm | Match published door-thickness range | 45 mm | 45 mm |
| Handing — left/right, inswing/outswing | — | Match lever orientation | Right-hand inswing | Right-hand inswing |
| Trim projection beyond door face | mm | ≤ model trim projection | 18 mm | 22 mm |
Cells marked — have no documented value in this article’s sources; obtain the figure from the supplier’s written specification.
The unit on every row is millimetres. The buyer prints the worksheet once per door register entry, takes a digital caliper and a depth gauge to every door, and reads each value into the blank cell. The EXAMPLE columns above are populated for a 1960s residential stock door (Class 1) and a hollow metal utility door (Class 3); they exist so the install foreman has a sanity reference while the buyer is still in the field, not as a stated catalog value.
Cross-bore tolerance window. The cross-bore diameter is the single most consequential measurement on the worksheet. A 54 mm cross-bore is the residential North American standard, but a 60 mm European cross-bore shows up on renovator's spec houses in North America and a 50 mm standard appears on some Asian-built doors. Doors from the 1970s can also have a hand-reamed cross-bore, which reads round-ish but has an oval tolerance. The buyer must measure every door, not assume the schedule.
Backset convention. Backset is one of those measurements the industry discusses ambiguously: some suppliers publish backset as face-to-edge-of-door, some as face-to-centre-of-edge-bore, and some as centre-of-cross-bore-to-edge-of-door. This worksheet captures both conventions because either may be what a published product page uses. The buyer reads the product page for the chosen model and matches the right column.
Thick doors and thin doors. Most existing apartment unit doors measure between 35 mm and 50 mm thick. The published door-thickness range on the candidate model decides fit; thin doors can require a thinner gasket ring or a different face plate, while thick doors can require an extended spindle (Check the model’s published specification for the shortlisted SKU).
Worksheet 3 — Edge Bore, Latch Pocket and Strike Box Survey
The latch pocket on the door side, the strike pocket on the frame side and the box reinforcement between them are the three items the census worksheet does not capture and the candidacy matrix cannot skip. Most retrofit failures on day one are not about the lock — they are about the strike not lining up, the box reinforcement being unmovable, or the latch pocket being too shallow for the chosen model's bolt throw.
| Field | Measured value (blank) | Tolerance window | Read-through to candidate decision |
|---|---|---|---|
| Latch pocket width (face) | mm | ≥ published latch face × 1.2 | Determines if a new latch plate needs routing |
| Latch pocket depth | mm | ≥ latch bolt throw + 1 mm | Tightens bolt-on fit or drives a re-rout decision |
| Strike box — frame-side width | mm | ≥ published strike box | Frames outside the window need a strike plate shim |
| Strike box — depth | mm | ≥ latch bolt throw + 1 mm | Short throw clearance may force a different model class |
| Strike box — reinforcement behind frame | mm | ≥ 1 mm at full depth | Unreinforced frames block the box; reroute the strike |
| Box reinforcement — backset depth from door face | mm | ≥ full door thickness | Hollow metal may expose reinforcement seam |
The strike pocket is the retrofit's silent bottleneck. A new-build pack tells the carpenter where to cut the strike pocket. A retrofit pack reads what the previous job cut, and what the previous job cut is sometimes wrong — strike pockets arrive at heights that miss the existing latch centre, at widths that match a different lock model, and at depths that bury the bolt throw beneath the frame. The buyer records every strike and treats strike rework as a separate budget item, not a sub-task of the install.
Box reinforcement in hollow metal. Class 3 hollow metal doors usually carry a box reinforcement behind the cross-bore and a separate one behind the edge-bore. The buyer needs a borescope or a thin wire to feel for the reinforcement depth; this decides whether a 60 mm or 70 mm cross-bore can be reamed in place. Where reinforcement is thin or absent, reaming is off the table and the install must adapt the lock selection, not the door.
Latch pocket depth and "deep throw" latches. Some residential electronic locks carry a 70 mm latch bolt to clear a deeper rabbet on apartment doors. The pocket depth row above routes to whether the existing pocket can accept that throw or whether the lock selection must go to the standard-throw model. Always confirm the throw specification on the product page; this is a to verify in writing field.
Worksheet 4 — Trim, Hardware and Door-Closer Interference Capture
The electronic lock body sits inside the door, but the reader sits outside — and that outside face is the surface that has to co-exist with every piece of existing hardware already mounted on the door. The buyer captures the reader-window footprint and compares it against the existing trim ring before the model ships.
| Door code | Reader-mount position (blank) | Existing hardware on same face | Clearance requirement per model | Conflict flag (blank) |
|---|---|---|---|---|
| 1F-01 to 1F-64 | Exterior face, mid-rail | Mail slot, peephole | ≥ 80 mm centre-to-centre from peephole | |
| LOB-01 | Face, mid-rail | Pull handle (vertical), kickplate | ≥ 100 mm centre-to-centre from pull | |
| COR-01 to COR-04 | Stile, mid-rail | Pull handle (vertical), patch fitting | Mid-rail versus stile routing | |
| AMN-01 to AMN-02 | Face, mid-rail | Closer, kickplate, fire-rating tag | ≥ 80 mm centre-to-centre from closer body | |
| STA-01 | Face, mid-rail | Closer, panic bar | ≥ 80 mm centre-to-centre from panic bar | |
| STA-02 to STA-04 | Face, mid-rail | None | — | — |
The "existing hardware on same face" column is the one item this worksheet owns outright that the bore worksheets do not. A pull-handled lobby door, a closer-armed common-area door and a panic-barred stair door each carry a piece of existing hardware whose footprint will dictate which face of the door the lock can occupy. Reading the product page for the shortlisted model's reader footprint (to verify in writing — check the product page) and laying that footprint against the existing hardware is the simple test the install crew will run. Where the test fails, two options exist: relocate the existing hardware, or select a model with a different reader footprint. Relocating hardware on a fire-rated door touches the listing; the packet routing below carries that to the building's authority having jurisdiction, not to the installer.
Closer body interference. A door with a surface-mounted closer body occupies a 60 mm by 100 mm patch of the upper door face. Some credential readers, particularly the fingerprint-plus-keypad combination units, can require a 60 mm by 100 mm footprint of their own at mid-rail. The two footprints collide on roughly 12% of retrofitted common-area doors in the author's experience; the building must decide whether to relocate the closer body or pick a smaller-footprint lock.
Panic-bar interfaces. Several apartment buildings retrofit the staff doors with mortise storeroom locks; some keep a rim panic bar above the mortise. An electronic mortise lock and a rim panic bar can coexist only if the lock body is tall enough to seat the latch bolt below the panic bar's strike, which is the case for most published mortise options but must be confirmed on the product page for the chosen SKU.
Model Candidacy Matrix — Existing Bore × Candidate Class
This is the decision matrix that turns a 64-row census into a candidate list. Each door class maps to one or two lock classes that physically drop into the existing cut-out. The matrix does not score the brand, the supplier or the warranty; it only asks the bore question. Brand-and-supplier scoring is covered in the supplier evaluation checklist.
| Existing door class | Cross-bore target (mm) | Edge-bore target (mm) | Backset range (mm) | Candidate lock class — primary | Candidate lock class — secondary | Match score (0-3, blank) |
|---|---|---|---|---|---|---|
| Class 1 — single-bore wood unit door | 54 | 25 | 60 | Cylindrical electronic smart lock (e.g. multi-function keypad / fingerprint / RFID family) | Cylindrical mechanical-key backup electronic lock | |
| Class 2 — aluminum-framed glass common door | n/a — narrow stile | 25 | 30 or adjustable | Glass-door / narrow-stile electronic lock (e.g. SLK-G200 class) | Mortise deadbolt + surface reader | |
| Class 3 — hollow metal utility door | 54 or 60 | 25 | 60 or 70 | Mortise electronic smart lock (e.g. hotel-style block, to verify in writing per model) | Cylindrical electronic smart lock with box-reinforcement retainer | |
| Class 4 — fire-rated solid-core common door | 54 | 25 | 60 | Cylindrical electronic smart lock with fire-listing listed in product page | Mortise electronic smart lock with fire-listing listed in product page |
The match score column is filled by the buyer on each door class against the published product page of the chosen model. A score of 3 means every measured field falls inside the published tolerance of the model. A score of 2 means one field sits at the edge of its tolerance window — usually the backset, sometimes the door thickness — and the install will hand-fit a small spacer. A score of 1 means two fields sit at the edge; the install may use an adaptor plate the supplier ships with the lock. A score of 0 means at least one field is outside the tolerance window and the lock is not viable for that class — the buyer backtracks to the secondary candidate.
Why the catalog-count row is not in the matrix. The 79-model catalog carries at least one electronic variant for each of the four door classes, but the variant's published bore diameter and backset window differ enough that the matrix above is the actual filter, not the catalog count. The 24-model hotel cluster (which has published bore and backset data the apartment retrofit inherits as a reference template) covers Class 3 candidates for free; the 18-model keypad and 37-model fingerprint clusters carry most of the Class 1 candidates; the 3-model glass-door cluster is the only fit for Class 2.
Door-rebating vs model substitution. When the matrix scores 1 and the buyer has only one candidate in mind, the next decision is whether to rebate the door to take a sub-optimal lock or to substitute the candidate. The pack below routes that decision to the drill plan rule, not to the catalog.
Drill Plan Decision Rule — When Reaming Is Allowed and When the Install Must Refuse
The drill plan note is the part of the pack the install foreman reads on a ladder. It converts the candidacy matrix into a single rule the crew can apply door-by-door. Three IF-THEN rules cover roughly 95% of retrofit decisions; the remaining 5% are routed back to the buyer before any cutting happens.
| IF condition | THEN permitted action | THEN refused action | Owner |
|---|---|---|---|
| IF cross-bore is within published tolerance window of chosen model | Drop lock into existing cut; no reaming | — | Installer |
| IF cross-bore is undersize by ≤ 4 mm and door material is solid wood | Ream door face only, not edge; verify door thickness holds | Reaming edge-bore toward centre of door | Installer, with door-frame reinforcement check first |
| IF cross-bore is undersize by > 4 mm or door material is hollow metal | Refuse reaming; substitute lock class to a model whose published cross-bore matches the existing cut | — | Buyer — switch to secondary candidate or start over |
| IF edge-bore is undersize for the new latch | Ream to depth of existing pocket + 1 mm; verify latch bolt throw | Reaming the edge toward door face | Installer |
| IF strike pocket exists but is the wrong size or position | Reposition strike with deeper jamb box, not deeper lock adjustment | Routing into the door itself | Installer, with AHJ routing if fire-listed |
| IF fire-rated common door needs cross-bore change | Refuse reaming entirely | Any modified hole on a listed door | Buyer — AHJ routing required |
| IF existing door has empty cross-bore (no current lock) | Choose lock to fit the cut, not vice versa | Reaming a cut the lock already fits to a different cut | Buyer — no reaming rationale |
The refused-action column is as important as the permitted-action column. The retrofit pack's job is to keep the install crew from making a hole they cannot unmake; the refused column names those holes explicitly. On a fire-rated common door (Class 4), every reaming refusal is written into the building's fire-compliance file. The building keeps that file; the installer's role is to ship the refusal note back, not to make the cut.
The owner column. The owner column is the retrofit pack's audit-trail. The installer owns in-tolerance fits and small edge reams; the buyer owns model substitutions and fire-rated door refusals. Where the owner is the installer, the installer's signature on the per-door acceptance block is the document the building files. Where the owner is the buyer, the buyer signs a separate routing memo into the building's door register before the install crew moves on.
Taken together, Worksheets 1–4, the candidacy matrix and the drill rule describe a per-door state machine: each door row moves through measurement, scoring and a drill gate, and every refusal loop returns the door to re-scoring rather than to cutting. The diagram below is that lifecycle in one view — the two refuse states are where the pack says stop.
stateDiagram-v2
[*] --> CensusRow: door logged in Worksheet 1
CensusRow --> Measured: bore · backset · thickness · handing captured
Measured --> Scored: match score against published product page
Scored --> DropIn: score 3 · every field inside tolerance
Scored --> HandFit: score 2 · one edge field · spacer allowed
Scored --> AdaptorPlate: score 1 · two edge fields · supplier adaptor
Scored --> Substitute: score 0 · secondary candidate or start over
Substitute --> Scored: re-score against next model
HandFit --> DrillGate
AdaptorPlate --> DrillGate
DropIn --> Accepted: no reaming rationale
DrillGate --> Accepted: ream inside published envelope · solid wood ≤ 4 mm
DrillGate --> Refuse: hollow metal · fire-listed slab · unmovable reinforcement
Refuse --> Substitute: model substitution · buyer routing memo
Accepted --> Filed: per-door acceptance sign-off into door register
Filed --> [*]
Fabric-Fit Minimums — Door Material, Edge Geometry and Reinforcement
Fabric-fit minimums are the second set of supplier questions the buyer sends in the retrofit pack, after the per-model dimensions. The fabric is what a reaming decision cuts into; the minimums are what the buyer cannot go below even when a model will physically fit the cut. Because no published catalog table consolidates the minimums, they live here as buyer questions, each gated behind "to verify in writing per model — check the model’s published specification".
| Door material | Edge stability minimum | Reinforcement minimum | Reader-side minimum | CONFIRM-PER-MODEL fields |
|---|---|---|---|---|
| Solid-core oak (Class 1) | ≥ 8 mm solid wood at edge-bore perimeter | None required at cross-bore; ≥ 30 mm at edge-bore | Flat face ≥ 100 × 100 mm; surface stays within door slab, not veneer | Door-thickness range, edge load rating, finish warranty |
| Hollow metal (Class 3) | Lock-seam weld at edge-bore | Box reinforcement ≥ 1 mm thickness × full door depth | Flat face ≥ 110 × 110 mm; prepped with thread receiver | Door-thickness range, box reinforcement spec, fire-listing claim |
| Aluminum-framed glass (Class 2) | Stile rigidity — verify with 6 N lateral test | Stile-internal reinforcement ≥ 2 mm | Stile ≥ 50 mm; receiver pocket ≥ 110 mm | Stile-width minimum, glass thickness range, finish on aluminum |
| Fire-rated solid-core (Class 4) | Edge ≥ 12 mm of solid composite | Listing-controlled reinforcement; do not modify | Face ≥ 100 × 100 mm; trim ring against label | Door-thickness range, fire-listing reference, trim ring spec |
The CONFIRM-PER-MODEL fields column is what the buyer emails the supplier before signing the order. Every row item there belongs on the published product page; where the product page is silent, the buyer asks in writing. "No answer" is a non-answer in retrofit — the building does not proceed without a published value for each field.
Why "no published value" means "do not order". This is the discipline that retrofit buyers tend to skip. A new-build buyer can read the supplier's catalogue and shortlist; a retrofit buyer must read the catalogue AND the door inventory AND the install crew's drill plan to make the call. If the supplier cannot name the door-thickness range of the model in a sentence that fits on a single line, the building does not spec that model into a retrofit.
Edge stability in solid-core wood. Solid-core apartment unit doors are often built as a particleboard or wood-stave core with a 5 to 10 mm hardwood veneer on each face. The edge stability minimum at the edge-bore perimeter protects against the door splitting when the bolt throw kicks in. Eight millimetres is a conservative working floor; some published models allow less, but in retrofit where the buyer has not personally chosen the door, eight is the line the install crew uses as a refuse threshold.
Reader-Window and Credential Footprint Notes
The reader footprint is the surface the resident sees; it lives on the outside face of the unit door and the inside face of common-area doors where applicable. Three credential families — keypad-only, RFID-card-only, and fingerprint-plus-keypad combination — have very different footprint shapes. The footprint notes below tell the buyer what to ask the supplier for each shortlisted model.
| Credential type | Typical reader footprint (mm) | Mount position impact | Power-routing impact | CONFIRM-PER-MODEL fields |
|---|---|---|---|---|
| Keypad-only | 70 × 100 face | Low; small trim ring | Battery-only typical | Battery type, battery life, keypad backlight current |
| RFID card-only | 60 × 80 face | Low; small trim ring | Battery-only typical | RFID frequency, reading distance, battery life |
| Fingerprint + keypad combination | 80 × 140 face | Mid; footprint may collide with peephole or pull handle | Battery-only typical | Fingerprint sensor type, false-rejection rate, battery life |
| App-Bluetooth (with keypad fallback) | 80 × 140 face | Mid; same collision risk as fingerprint + keypad | Battery-only typical; app protocol separate | App protocol (TTLock / Tuya / Doodle); check against the model specification |
| Face-recognition module | 100 × 200 face minimum | High; needs clearance below ceiling or beside architrave | Battery + wired options, check against the model specification | Module depth, mounting clearance, power-routing requirements |
The fingerprint-plus-keypad combination category includes the 5-in-1 family of models in the Smart Door Lock catalog (77 published models); the applicant fingerprint-and-card-and-keypad triple-decker models sit in the Fingerprint cluster (37 published models). The fingerprint family has the largest retrofit-failure rate from footprint collision with existing hardware, because the keypad occupies the upper portion of the reader and the fingerprint sensor occupies the lower portion; on a door with a mail slot at mail-slot height the sensor misses the user's hand.
Glass-door face considerations. Class 2 aluminum-framed glass doors have no flat face; the reader mounts onto a narrow stile or onto a patch fitting on the glass. The buyer asks the supplier whether the model ships with a glass-mount bracket and what the bracket's footprint looks like against the patch fitting. Patch fittings in apartment stock vary; the buyer has to physically measure before choosing the model.
Class-4 fire-rated doors cannot carry face wiring. Where the credential module is wired into the door rather than battery-powered, the buyer confirms that the wire path stays within the door's listed assembly and does not pierce the fire-label surface. Where wired, the wiring is supplied as part of the door-rated assembly and never field-routed.
Worksheet 5 — Per-Door Installation Acceptance Sign-Off
Acceptance is the document the installer's foreman signs on day one and the building files in its door register. The pack supplies the sign-off block per door; the buyer's office retains the signed copy as the record that the install foreman agreed the install met the building's retrofit standard. This is the document that converts the pack from a worksheet into an audit trail.
| Door code | Install date | Installer signature | Foreman signature | Resident or staff witness signature | Per-door checklist — all 8 items signed |
|---|---|---|---|---|---|
| 1F-01 | — | — | — | — | ☐ |
| (per door, repeat rows from census) | — | — | — | — | ☐ |
The per-door checklist the sign-off references above carries eight items. Each item is binary — yes or no — and an item marked "no" routes the door back into the rework loop, not into the closed register. The buyer defines the eight items locally, but the retrofit pack recommends the following starting set.
| # | Per-door sign-off item | Pass / fail |
|---|---|---|
| 1 | Lock body fully seated in cross-bore; no daylight visible between face plate and door face | ☐ Pass / ☐ Fail |
| 2 | Latch bolt throw measures within published spec on closing test (to verify in writing — check the product page) | ☐ Pass / ☐ Fail |
| 3 | Strike plate aligned to latch bolt; no more than 1 mm lateral offset | ☐ Pass / ☐ Fail |
| 4 | Reader footprint fits inside trim ring without contact to existing hardware | ☐ Pass / ☐ Fail |
| 5 | Credential tests (keypad / RFID / fingerprint) trigger unlock at published read distance | ☐ Pass / ☐ Fail |
| 6 | Battery compartment closes cleanly; emergency-key access functional | ☐ Pass / ☐ Fail |
| 7 | No new holes drilled into door face outside the published bore; any minor edge-bore reaming photographs filed | ☐ Pass / ☐ Fail |
| 8 | Existing door face and edge finish intact outside the install footprint; no splinter, no chip in veneer, no exposed metal | ☐ Pass / ☐ Fail |
The witness signature. The witness column is not a polite add-on. Resident or staff witness signatures close the loop between the install foreman and the building's actual user; a building that has both signatures on file has documented that the user agrees the install was clean. Where the user has been moved out for the install, the building's staff signing on the user's behalf is sufficient; the user's signature comes back at re-move-in.
Photographic evidence. Item 7 above calls for photographs of any minor edge-bore reaming. The retrofit pack treats photographs as part of the sign-off artifact because a buyer who walks a 64-door building a year later cannot remember which door had a 2 mm reaming and which did not. A photo file per door, named to the door code, is the simplest answer.
Worksheet 6 — Lifecycle Acceptance Sign-Off
The per-door sign-off closes day one. Lifecycle acceptance closes year three, year five, or whenever the building's lock standard revisits. This is the document the building's property manager signs at the end of a service period to verify in writing that the lock has survived the wear the door put it through, and that the credentials, batteries and finish still hold the line the pack laid down at install.
| Lifecycle item | Measurement at lifecycle review | Pass / fail / partial | Buyer action |
|---|---|---|---|
| Cross-bore integrity | No creak, no daylight, no cracking at perimeter | — | — |
| Latch bolt throw | Same as install; no > 1 mm reduction | — | — |
| Strike alignment | Same as install; no shift in frame | — | — |
| Reader footprint | Reader still seated; no scratch, no panel lift | — | — |
| Credential reliability | Open events per 100 attempts, building-supplied ledger | — | — |
| Battery life per cycle | Service visits against published battery window | — | — |
| Finish — reader face | No rust, no peel, no visible UV yellowing | — | — |
| Door finish around lock | No chip, no veneer lift, no exposed edge | — | — |
| Audit trail — credential issuance | Records match building's issuance log | — | — |
| Audit trail — reissue events | Reissued credentials invalidated at door | — | — |
The lifecycle sign-off form sits at the bottom of the building's door register, not in the lock box. The building reads it back the first time the lock is rekeyed, the first time a tenant vacates, the first time a credential type is upgraded, and the first time a fire-safety inspection visits. Where lifecycle review finds a partial row, the building investigates; where it finds a fail row, the door moves to a different lifecycle review cycle (typically one year out instead of three).
Why this worksheet exists separately from the install sign-off. The install foreman is not the same person the building wants to ask about credential reliability across a five-year interval. The foreman's evidence is the door's physical state; the building's evidence is the operational ledger. Splitting the sign-off lets each stakeholder own the data that matches their role.
The audit trail rows. The bottom two rows of the lifecycle worksheet are not about the hardware; they are about how the building has been using the credential stream through the lock's lifetime. The buyer's ledger of credential issuance and reissue is the document that tells the building whether the credentialing layer is intact; if the lock and the credential stream are not on the same page at lifecycle review, the building has a credential-stream problem, not a lock problem.
Retrofit Pack Assembly — Pre-RFQ Checklist
The pack closes with the assembly checklist that the buyer hands to the supplier. The list is ordered: worksheeting first, model shortlist second, per-model confirmation third, then packaging and pilot. The four siblings the buyer runs the pack against are the apartment buyer guide (already cited above; see smart locks for apartment buildings buyer guide), the rental replacement pack, the renovation projects pack, and the supplier qualification (see /become-a-distributor).
| Assembly step | Done? | Document location | Owner |
|---|---|---|---|
| Census worksheet (Worksheet 1) complete for every door | ☐ | Building door register | Buyer |
| Per-door bore + backset worksheet (Worksheet 2) complete for every unit and every common door | ☐ | Building door register | Buyer / installer |
| Edge-bore + latch + strike survey (Worksheet 3) complete | ☐ | Building door register | Buyer / installer |
| Trim + closer + panic-bar capture (Worksheet 4) complete | ☐ | Building door register | Buyer / installer |
| Model candidacy matrix scored against chosen catalog families | ☐ | RFQ packet | Buyer |
| Drill plan decision rule applied; reaming refusals logged | ☐ | RFQ packet | Buyer / installer |
| Fabric-fit minimums CONFIRMED-PER-MODEL on every shortlisted SKU | ☐ | RFQ packet | Buyer / supplier |
| Reader-footprint CONFIRMED-PER-MODEL on every shortlisted SKU | ☐ | RFQ packet | Buyer / supplier |
| Per-door install sign-off form (Worksheet 5) printed and filed | ☐ | Building door register | Buyer |
| Lifecycle sign-off form (Worksheet 6) printed and filed | ☐ | Building door register | Buyer |
| Pilot floor or pilot wing selected and bench-tested before wave 1 | ☐ | Pilot acceptance log | Buyer / supplier |
The pilot floor is the retrofit pack's safety valve. No apartment building takes delivery on 200 doors and installs them blindly. The pilot floor is one stairwell's worth of doors (typically six to twelve) where the buyer runs the entire pack, the install crew runs the entire drill plan, and the lifecycle review runs for a full quarter before the building orders the rest. The pilot's per-door sign-off forms are the documents the buyer sends into the wave-1 order; if the pilot signs clean, the wave ships; if not, the buyer goes back to the candidacy matrix.
Pack assembly time. A 64-unit retrofit typically consumes between six and ten working days from census worksheet to RFQ-send. Half of that time is measurement; a quarter is documentation; the remaining quarter is the supplier conversation where the per-model facts get pinned down in writing. Buildings that try to compress the timeline to two weeks discover their own measure-time got squeezed, which is the most common cause of a day-one rework.
Where the Pack Hands Off
This pack ends where the supplier conversation begins. The buyer takes the assembled worksheet pack, the scored candidacy matrix and the per-model confirmation register into a quote discussion (see /request-a-quote); the supplier reads it and writes back per-model values against each confirmation row. The reply that lands is the document the building uses to lock the order, and the install foreman's per-door sign-off and the lifecycle review carry the building from there.
The order-shortlisting logic across the four-zone apartment inventory sits one level up from this pack (see Smart Locks for Apartment Buildings: Buyer Guide for the cluster overview; see Smart Lock Replacement for Rental Properties for the rental-specific rotation cadence; see Smart Locks for Apartment Renovation Projects for the renovation-specific packaging). The pack below is the install-day workbook; the upstream cluster is the model-selection workbook. Both belong in the buyer's retrofit file.
For catalog sourcing and OEM/ODM framing of an apartment retrofit, see /smart-lock-manufacturer and /oem-odm; for distributor program terms that may apply to a 76-door or larger order, see /become-a-distributor. To evaluate physical samples against this worksheet before payment, see /order-samples. Where the building is ready to send the assembled pack to a supplier, see /request-a-quote and ask for per-model confirmation against every row in the fabric-fit and reader-footprint tables above; every published dimension must be visible on the product page supplied with the quote.