Consider a small two-practitioner primary-care clinic on the ground floor of a mixed-use building, sixty feet of frontage on a busy street, four doors in

Zveřejněno v:: říj 09, 2026

Smart Locks for Clinics

Smart Locks for Clinics

Consider a small two-practitioner primary-care clinic on the ground floor of a mixed-use building, sixty feet of frontage on a busy street, four doors in total: a patient-facing front door, an internal practitioner corridor door, a sampling/treatment room at the back, and a staff-only rear door that doubles as the courier entry. The clinic opens at 08:30 and closes at 18:00 on weekdays, closes Saturday afternoon, and is fully shut Sunday. Monday morning the first practitioner arrives at 07:50 to open up; the second arrives at 09:15 after hospital rounds; a contracted cleaning crew arrives at 19:15 on weeknights; a courier from the reference lab stops between 11:30 and 14:00 every weekday to pick up blood and swab samples; a private phlebotomist rents the sampling room two afternoons a week and walks in through the front door with her own patients. That is one location, eight weeks into operation. It is an illustrative scenario assembled from what we see order-side at a factory that has shipped smart locks for more than ten years — not a customer story, not a testimonial — but the pattern is recurring in small outpatient clinics everywhere.

Here is the direct answer, stated before anything else for extractability:

Smart locks for clinics are a five-stage daily arc, not a product. A small clinic runs on five distinct door moments that behave differently — the open-prep moment when the first practitioner arrives, the practitioner-door discipline moment when staff cross between rooms during opening hours, the sample-pickup coordination moment when an outside courier arrives at an unscheduled window, the after-hours cleaning-crew moment when contracted labour enters an empty clinic, and the week-end lock moment when the clinic closes for forty-eight hours or longer. The right design separates five credential populations (lead practitioner / covering practitioner / contracted courier / contracted cleaning crew / phlebotomist-renter), picks a model whose lanes match those populations, and treats the open and close of every day as a written discipline rather than a memory. Off-the-shelf retail smart locks do most of this poorly because they were designed for a household of four, not a clinic of two practitioners with a daily courier and a weeknight cleaning crew all flowing through the same door.

What follows earns that paragraph stage by stage, then turns it into a specification conversation you can take to a supplier without inventing facts about any one model.

Why a clinic's door is not a household's door — and not a hospital's either

A clinic sits in a different neighbourhood from both the residential smart lock and the institutional one. A household sees a handful of trusted faces a day, rotating maybe forty distinct credentials a year. A small clinic in steady state can rotate that many contractor-issued codes in a single month — covering locums, lab couriers, cleaning crews, equipment technicians, fire-extinguisher inspectors, building managers for the upper-floor landlord — plus a stable staff lane for two or three practitioners and one or two receptionists, plus a patient-facing lane that on a busy day touches forty appointments and never recycles a credential.

A hospital, by contrast, runs twenty-four hours a day, sees hundreds of staff in three shifts, and serves inpatients who do not interact with door credentials at all. Hospital access is governed by department logic, badge tiers, controlled-substance rooms and emergency-department lockdown — questions answered elsewhere, on Smart Locks for Hospitals, and deliberately not duplicated here. What hospitals do not do well is be small. A hospital-grade access system on a clinic is a multi-thousand-dollar commissioning exercise on a fifty-thousand-dollar annual rent — the cost-to-traffic ratio is upside down.

A clinic sits between those two reference points. The lock product on the door is closer to a hotel-class electronic lock or a multi-function residential-class lock than to either a consumer deadbolt or a hospital wired ACS. That is what the rest of this article selects for. The clinic-specific work is not the model choice; the clinic-specific work is the credential choreography across one day, and that is what the rest of this article walks through.

Five clinic realities drive every recommendation in this article:

  • The first person through the door in the morning is not the same person as the last person through the door at night. A household has roughly the same opener and closer; a clinic rarely does. The Monday opener might be Practitioner A on this week's rota; Tuesday's opener is Practitioner B; Friday's closer is the cleaning crew who never opens.
  • The practitioner-door discipline is the security centre of gravity during opening hours. Patients see the front door. Practitioners move between the front, the practitioner corridor, and the sampling room. The corridor door is the actual perimeter during opening hours — not the front door.
  • The sample-pickup courier is a credential-shaped problem. The lab courier is not staff. They arrive at a window the clinic does not fully control. They need access to one room only, for under five minutes, and the clinic needs a record that ties the pickup to a credential that was issued for that window.
  • The cleaning crew is the most-overlooked credential population. They arrive after the clinic is empty. They have keys or codes from a previous arrangement. They are unsupervised. They touch every room. Their credential is the one that most often outlives the contract.
  • The week-end lock is a different problem from the night lock. A week-end lock is not "did we forget to set the alarm"; it is a forty-eight-hour period where the only authorised entry is the on-call practitioner, and that on-call identity rotates weekly.

The four doors behind a clinic — door schedule as the spine

Before any spec sheet is written, you sit down with the lead practitioner and walk the clinic as each user would, room by room. Below is the door schedule the exercise produces for a clinic roughly the size of our illustrative scenario. Every line is a buyer's planning output. Whether a particular model covers the lanes named in each cell is a separate question — that is the to verify in writing step that no proxy answer can replace.

DoorClassPrimary credentialBackup laneEgress / failureAudit-grade requirement
Patient-facing front doorPublic-facing clinic doorReception staff lane during opening hours + practitioner lane + time-bounded cleaning-crew code after hoursMechanical key in the practitioner-safeFree egress inside at all times; mechanical override accessible from inside; outside fail-securePer-day open / close event; cleaning-crew code issuance and entry
Practitioner corridor door (front → back-of-house)Staff-only internal doorStable practitioner lane (per-practitioner code or card)Mechanical key in practitioner-safeSame — fail-secure outside, free insidePer-practitioner entry log; flag for any entry outside opening hours
Sampling / treatment roomHigh-value clinical roomPractitioner lane + phlebotomist-renter lane + time-bounded courier codeMechanical key in practitioner-safeFree egress inside; mechanical override with custody logPer-procedure credential record; courier pickup event tied to issued code
Staff-only rear door (courier entry)After-hours / courier doorTime-bounded courier code + cleaning-crew codeMechanical key in practitioner-safeFree egress inside; mechanical override with custody logPer-window issuance with courier identity; cleaning-crew daily code with contract-tied identity

Three things are worth naming about the schedule above. First, the patient-facing front door and the practitioner corridor door are intentionally separate credentials even if they share a code value during opening hours — that way, a contractor who legitimately got into the front door can be revoked from the corridor without being revoked from the front. Second, the sampling room is named separately because it has the highest-value audit requirement and the most credential populations (practitioner, renter, courier, cleaning crew). Third, the rear door is named in the schedule because it is the courier's natural entry and the cleaning crew's natural entry, and pretending they will use the front door is the most common reason a clinic buys the wrong model on opening day and then retrofits within six months.

Walk the illustrative clinic through the doors above, from the 07:50 arrival on Monday to the Sunday close, and the five stages named at the top of this article appear as one continuous trip:

journey
    title One clinic day as five door moments
    section Open-prep
      Lead practitioner unlocks · reads the overnight cleaning log : 5 : Lead practitioner
      Second practitioner arrives after hospital rounds : 3 : Covering practitioner
    section Practitioner-door discipline
      Staff cross the corridor door during clinic hours : 4 : Practitioners · reception
      Patient stays on the lobby side of the corridor : 5 : Patients
    section Sample pickup
      Lab courier enters for the sampling-room window : 3 : Reference-lab courier
    section After-hours cleaning
      Contracted crew works the empty clinic : 2 : Cleaning crew
    section Week-end lock
      On-call credential carries forty-eight closed hours : 4 : On-call practitioner

Stage 1 — Open-prep: the first practitioner in

The day starts with the lead practitioner. They arrive ten to twenty minutes before the first appointment, disarm any alarm that the alarm company has installed alongside the lock, and walk the corridor to verify in writing the previous evening's cleaning-crew exit was logged. The credential they use is the most powerful single credential the clinic issues: it opens every door, every time, with no time window. That is appropriate — the lead practitioner on rota is the clinic's security principal for the day — but it is also the credential most likely to be lost, lent, or copied without thought.

Three design disciplines govern the open-prep stage:

  • The lead practitioner's master credential is named, not anonymous. It is issued to a specific person with a start date, and is revocable on the day they leave. Whether a particular model supports per-credential naming with audit-trail-friendly identifiers is a product-page question — check the model’s published specification.
  • The master credential is paired with a written open-and-close checklist. The checklist lives next to the lock, not in the practitioner's head. It names the alarm code, the mechanical-override key location, the day's rota, and the previous evening's cleaning-crew log. This is a discipline, not a product feature; the lock cannot enforce it.
  • The first-arrival event is the day's audit anchor. Every credential the lock issues that day is anchored in time by the first-arrival event. If that event is missing — the clinic opened, the lock says it did not — there is a credential-management problem on top of whatever else is wrong.

Stage 2 — Practitioner-door discipline during opening hours

Once the clinic is open, the practitioner's relationship to the doors changes. The patient-facing front door is the receptionist's responsibility — staff codes, scheduled appointments, walk-ins. The practitioner corridor door becomes the perimeter. The sampling room is reached only through the corridor, never from the front. Every practitioner carries a stable per-person credential — code or card — that works for the full shift and revokes cleanly when they leave.

Four design disciplines govern this stage:

  • Each practitioner has a named credential, not a shared "staff" code. If Practitioner A leaves on the Friday and Practitioner B starts on the Monday, the credential for A is removed before B's first shift. The lock does not enforce this; the rota does.
  • The covering-locum lane is its own population. When a locum covers a shift, they are issued a time-bounded credential — start date, end date, scope of doors — that does not outlive the engagement. Whether your model supports per-credential windows with named individuals is a product-page question — check the model’s published specification.
  • The practitioner corridor door is the lock's busiest door during opening hours. It opens and closes dozens of times a day. Battery wear, mechanical wear, latch wear all concentrate here. Spec for a model whose battery and latch duty cycle is honestly rated for this traffic — check the model’s published specification; the spec block in marketing copy often understates real-world door-open counts.
  • The patient never touches a credential. This sounds obvious but matters: the practitioner corridor door is the only door the patient should not be able to open from the lobby side. A model that lets a patient who has been admitted to the lobby push through the corridor door is the wrong model regardless of its other virtues.

The handover between practitioners at the shift change is its own moment. Where two practitioners overlap, the handover is a verbal plus a log-book event: who took over, when, and what was open at handover. Where they do not overlap, the morning practitioner's credential is the day's anchor until the afternoon arrives, and the afternoon practitioner's credential is issued only after the morning's audit is read.

Stage 3 — Sample-pickup coordination

The lab courier is the clinic's most time-sensitive and least-controlled credential. They arrive between 11:30 and 14:00 on a weekday, in a window the clinic does not fully control. They need access to the sampling room, sometimes briefly the corridor if the sampling room is locked from inside, for under five minutes, and the clinic needs a record that ties the pickup to a credential that was issued for that window.

Three design disciplines govern the sample-pickup stage:

  • The courier's credential is window-bounded and one-use-leaning. It is issued for the day's pickup window, scoped to the sampling-room door and the rear door if that is the courier's natural entry, and ideally rotates daily or weekly. Whether your model supports time-bounded credentials with named identity is a product-page question — check the model’s published specification.
  • The sampling room has a pickup-handover log separate from the lock's event log. The lock records who opened the door and when. The handover log records what was handed over and what the courier signed for. The two logs together are the clinic's audit-grade record. Neither replaces the other.
  • The courier's identity is the courier-company's responsibility, not the clinic's. The clinic does not vet the courier. The courier company does. The clinic's job is to issue a credential to a named individual provided by the courier company, not to a "courier role" or a shared pickup code.

A more sophisticated variant exists where the courier is one of several rotating between labs and clinics. In that variant the courier company maintains a roster and the clinic maintains a per-roster-entry credential, each tied to a photo ID the courier presents on arrival. The lock does not enforce photo ID; the receptionist does. The lock records who used which issued credential.

Where the clinic runs its own pickup — for example, a practitioner drops samples at a hospital lab on the way home — the practitioner's master credential covers the sampling-room door, and no courier credential is issued at all. This is simpler and worth naming: not every clinic needs a courier lane. The clinic that runs its own pickup skips Stage 3 entirely and re-tasks that credential population for the cleaning crew instead.

Stage 4 — After-hours cleaning crew

The cleaning crew arrives after the clinic is empty. They are unsupervised. They touch every room. Their credential is the most-overlooked population in the clinic's lock program and the one most likely to outlive the contract.

Four design disciplines govern the cleaning-crew stage:

  • The cleaning crew's credential is a time-bounded code, not a card or fob. Codes rotate weekly or monthly on contract anniversary. A lost or copied code is then a one-week or one-month exposure, not a permanent one.
  • The cleaning crew's credential is named to a roster, not to a company. The cleaning company provides a roster of named individuals; the clinic issues one credential per named individual, each with a contract-tied expiry. When an individual leaves the cleaning company, the cleaning company is responsible for telling the clinic to revoke that individual's credential — and the clinic's rota reflects that.
  • The cleaning-crew entry event is logged and reviewed. The lock records who entered and when. The lead practitioner reads that log on the next open-prep, and any anomaly (entry outside the contracted window, entry on a non-rota day, no corresponding exit event) is raised with the cleaning company on the next visit.
  • The cleaning crew is never given the master credential. They get the corridor, sampling-room and rear doors; they do not get the practitioner's master. The mechanical-override key is in the practitioner-safe, not in the cleaning-crew drawer.

A common shortcut is to give the cleaning crew a single shared "cleaning" code. Do not do this. A shared code removes the per-individual accountability that the contract is buying. If the cleaning company will not provide a roster, the clinic should change cleaning companies; the lock cannot fix that on its own.

Stage 5 — Week-end lock (and how it differs from the night lock)

The week-end lock is a forty-eight-hour or longer period where the only authorised entry is the on-call practitioner. The on-call identity rotates weekly in most clinics; some rotate monthly. The week-end lock is not "did we set the alarm"; it is the credential management of a multi-day empty building with one authorised entry path.

Three design disciplines govern the week-end lock:

  • The on-call credential is issued per rota-week, not per shift. It is scoped to the practitioner corridor door, the sampling room, and the rear door; it does not authorise cleaning-crew-style sweeping access. It starts Friday at close and ends Monday at open.
  • The week-end credential has an explicit expiry the lock enforces. Whether your model supports per-credential windows with hard expiry is a product-page question — check the model’s published specification. If the model only supports codes that the practitioner manually deletes, the week-end discipline depends on the practitioner's memory, which fails.
  • The week-end lock is paired with the alarm system, not substituted by it. The alarm is detection. The lock is prevention. The two are separate and both required; replacing one with the other is a category error that the lock spec cannot fix.

Where the clinic has a Sunday private-phlebotomist renter (some clinics do — the renter uses the sampling room on Sunday mornings for cash-pay blood draws), the renter's credential is a separate time-bounded lane layered on top of the week-end lock, scoped to the renter's actual hours. The week-end lock does not need to "open" for the renter; the renter's credential opens the specific door in the specific window and the rest of the clinic stays locked. This is the cleanest version of multi-population discipline the small-clinic program offers.

Cross-cutting concerns that survive across all five stages

A handful of issues cut across every stage of the day rather than belonging to one. They are worth naming separately because a buyer who designs for the stages but misses these will retrofit within a year.

ConcernWhat it isWhy it cuts across stagesWhere to confirm
Mechanical-override key custodyThe physical key that bypasses the lock entirelyEvery stage names it as the backup lane; its custody is a discipline, not a product featurePractitioner-safe, signed-out log, named holder per shift
Battery disciplineThe lock's battery is its only failure modeOpen-prep reads the battery state; practitioner-door traffic drains it; week-end lock cannot fail openProduct-page battery type and dead-battery behaviour
Audit-log reviewThe lock's event log is the clinic's audit trailOpen-prep reads yesterday's log; cleaning-crew events are reviewed the next morning; week-end credential events are reviewed MondayProduct-page audit depth and retrieval method
Credential naming conventionEvery issued credential has a human-readable nameStages 1–5 each depend on the practitioner reading the lock's user list and knowing what each credential isClinic-side discipline; lock supports per-credential naming if product page confirms
Dated product-page policySpec blocks change; the spec the clinic bought on day one is not the spec on day 365Every stage rests on a model whose features are documented as of the install dateClinic captures dated PDF of the product page at install and on each firmware update

Two of these deserve a second paragraph each.

Mechanical-override key custody. The mechanical-override key is the single physical artefact that bypasses the lock entirely. It is held in the practitioner-safe, not the reception desk, not the cleaning-crew drawer. Every shift that uses it signs it out and signs it back in. The lock cannot enforce this; the rota can. A clinic that treats the mechanical override as "a spare in the drawer" loses the audit-grade argument the lock is otherwise giving them.

Battery discipline. Most electronic locks in the small-clinic range run on standard cells — check the model’s published specification for the specific cell count and chemistry. The clinic's open-prep reads the battery indicator. The clinic's rota names a single battery brand so that no practitioner mixes chemistries and no cell-swap voids the lock's warranty path (warranty terms are quote-dependent and not asserted here — check the model’s published specification). The week-end lock cannot fail open; if the battery is uncertain on Friday afternoon, the lead practitioner swaps it before leaving.

Fact discipline — what this article claims and what it deliberately does not

A small clinic sits adjacent to several regulated domains — clinical care, specimen handling, patient privacy, controlled substances — and the temptation to claim territory in those domains is real. This article declines, by design, on three points.

  • No medical-grade or biocompatibility certification claims. Smart locks in this article's catalogue range are not medical devices in the regulatory sense; their enclosures are not characterised for body-fluid contact, sterile-field compatibility, or healthcare-specific electromagnetic compatibility. Where a clinic's procurement requires such characterisation, that is the practitioner's regulatory counsel's question — and is not answered here.
  • No patient-privacy or audit-compliance claims. The audit log a smart lock produces is a lock event log; it is not a clinical-record system, an access-control system for protected health information, or a substitute for the clinic's own privacy programme. Where a clinic operates under privacy regulation, the lock is a peripheral device in that programme, not the programme itself.
  • No infection-control claims. Door handles, keypads, RFID readers and biometric surfaces in this catalogue range are not characterised for cleanability, disinfection compatibility, or healthcare-facility surface standards. Where a clinic's procedures require such characterisation, that is the clinic's infection-control lead's question — and is not answered here.

What the article does claim, honestly and within the catalogue's evidence:

  • The catalogue includes 79 published models across 77 smart door locks, 24 hotel locks, 18 keypad locks, 9 RFID locks, 37 fingerprint locks, plus outdoor, face, cabinet, glass and video categories — a coverage map from which a small-clinic spec can plausibly be assembled, with per-model selection confirmed on the product page.
  • The factory has shipped smart locks for more than ten years and is sold into 80+ countries; OEM/ODM is the operating model; pricing is quote-based and not asserted here.
  • The hotel-class lock format (illustrated by the SLK-9936S spec block — door thickness 36–100 mm, RFID Mifare 1 @ 13.56 MHz, read distance 0–5 cm, read time under 0.25 s, four AA cells, battery operating cycles above 15,000, audit records up to 1,000, 5-pin mechanical cylinder, 3-point latch, stainless steel and alloy body, mechanical emergency access, multilingual management software, standalone or centralised database modes, positioned across one- to five-star properties) is the closest format analogue to a small-clinic door population; treat the SLK-9936S block as a documentation format ruler for what a per-model spec block should look like, and confirm per-model on the product page.

That last point is the discipline that runs through every recommendation in this article. The article names populations, windows, and disciplines. The article does not name specific models as the right answer for your clinic — because no article can, in good faith, without seeing the door, the door frame, the existing credential population, and the buyer's local regulations.

How this article differs from the siblings — explicit non-duplication

This article lives in a healthcare cluster of five siblings. The cluster is a deliberate set, and the differences matter so the buyer does not read the same article twice.

  • Smart Locks for Hospitals. Hospitals are 24/7, multi-shift, department-governed, controlled-substance-aware, and serve inpatients who do not touch credentials. That article owns the department-tier badge governance and the wired ACS coordination; this article deliberately does not.
  • Smart Locks for Medical Offices: A Solo-Doctor Scenario Across Front Door, Records Room, Sample Cooler and Drug Cabinet. Medical offices are larger multi-physician practices with front-desk volume and a steady patient-flow cadence that runs longer hours than a small clinic. That piece owns the multi-physician-rota and patient-flow credential population; this article's small-clinic lens is narrower — two or three practitioners in a sixty-foot-frontage unit — and the daily-arc structure is the differentiator.
  • Smart Locks for Pharmacies: A Door-by-Door Annotated Datasheet. Pharmacies are medication-dispensing points with controlled-substance storage, regulator-facing recordkeeping, and a different patient-credential model. That datasheet owns the controlled-substance and dispensing-record lens; this article deliberately does not.
  • Smart Locks for Medical Storage Rooms. Medical storage rooms are single-door specialty spaces (cold storage, specimen refrigerators, equipment closets, controlled-substance cabinets). Those rooms get a single-door specialty lens; this article is the four-door whole-clinic daily arc.
  • Smart Locks for Healthcare Staff Areas. Healthcare staff areas are the staff-only side of a larger healthcare building (break rooms, locker rooms, on-call rooms). The staff-area lens inside a hospital or large practice is that article's subject; this article's lens is the small standalone clinic where the staff area is one of four doors, not a wing of its own.

The cluster is a reading order, not a replacement set. A buyer who runs a small clinic should read this article first, then jump to Smart Locks for Hospitals only if their clinic is part of a hospital estate, to Smart Locks for Medical Offices: A Solo-Doctor Scenario Across Front Door, Records Room, Sample Cooler and Drug Cabinet only if their practice has grown past the small-clinic profile, and to Smart Locks for Medical Storage Rooms only if they are designing a single specialty storage room within an otherwise-unlocked clinic.

Putting the program together — a short decision walk

Three decisions sit on top of everything in this article. They are written as rules, not as product claims, because the rule is what survives the per-model confirmation step.

  • Decision 1 — Lead-practitioner master credential. Issue one named, dated, revocable master credential to the rota's lead practitioner per shift. Pair it with a written open-and-close checklist that lives next to the lock. The mechanical-override key is in the practitioner-safe, signed out and back in per use.
  • Decision 2 — Window-bounded credentials for every non-staff population. Couriers, cleaning crew, locum cover, renter phlebotomists — each is a separate time-bounded credential with named identity, scoped to the specific doors they need and the specific window they need it. None of them is a shared role credential.
  • Decision 3 — Week-end lock as a per-rota credential, not a setting. The week-end is a credential issued to the on-call practitioner for the rota-week, with a hard expiry the lock enforces. It is not a "set the lock to closed mode" toggle; it is a credential the lock grants or denies.

Three confirmations follow those decisions, and none of them can be skipped:

  • Confirmation A — Per-credential windows with named identity. Check the model’s published specification that the shortlisted model supports per-credential time windows, per-credential naming, and per-credential expiry that the lock enforces rather than relying on the issuer to remember to delete.
  • Confirmation B — Audit-log depth and retrieval. Check the model’s published specification that the lock's event log retains the volume of entries the clinic's audit cadence requires (the hotel-class spec block illustrates a 1,000-event ceiling; clinic volumes are typically lower but the retrieval path — app, software export, on-device read — is the question to verify in writing).
  • Confirmation C — Battery and mechanical-override behaviour. Check the model’s published specification the cell count, the dead-battery behaviour (does it fail-secure or fail-open? does it warn before?), and the mechanical-override cylinder type and keyway. The 5-pin mechanical cylinder in the hotel-class spec block is a format reference, not a recommendation; per-model is on the product page.

What to do with this article next is straightforward. Take the door schedule in this article's second section, take the five-stage discipline in the body, and take the three confirmations above to a supplier. The supplier's job is to show, on the product page, the per-model answer to each confirmation. Anything a supplier tells you that the product page does not back up is, at best, marketing copy — and is, at worst, a feature the clinic will rely on that does not actually exist.

For a clinic operator ready to specify, the right next step is a quote request against the four-door schedule with the five-stage arc named. The right secondary step is a sample order of one lock, installed on one door for a four-week evaluation against this article's discipline list. Pricing, minimum order quantity, and lead times are quote-dependent and not asserted here; the request-a-quote page is the path to those numbers.

For a multi-clinic operator or a healthcare-property owner reading this article as a template, the same five stages scale: the practitioner population grows, the cleaning crew's roster is consolidated, the courier lane is shared across sites, and the week-end lock becomes a per-site rota. The discipline does not change; only the credential counts do. That scaling is a procurement exercise, not a spec exercise, and belongs in a follow-on conversation with the supplier after the first clinic's program is proven.

The cluster — hospitals, medical offices, pharmacies, medical storage rooms, healthcare staff areas — is the wider reading. Within it, this article owns the small-clinic daily arc, and the five-stage discipline is what the next clinic you specify should be measured against.