Ansi bhma a156 13 versus ansi bhma a156 14 applicability: compare ANSI/BHMA A156.13 and A156.14 scopes to determine which evidence applies to a mortise smart.

प्रकाशित किया गया समय: जून 27, 2025

Ansi/bhma A156.13 Versus ANSI/BHMA A156.14: Which One Applies to Your Smart Lock Door

Ansi/bhma A156.13 Versus ANSI/BHMA A156.14: Which One Applies to Your Smart Lock Door

For ansi bhma a156 13 versus ansi bhma a156 14 applicability, treat the door as an assembly rather than a single “smart lock” product. A standard describes what it tests; it does not certify an entire opening. Procurement should separate the mortise lock body, push or pull exit device, electrical locking function, and door/frame context before assigning a standard.

Direct answer. The answer is component-specific: ANSI/BHMA A156.13 concerns mortise locks; ANSI/BHMA A156.14 concerns push and pull exit devices. If both appear on one opening

Separate the purchased hardware from the door assembly

Start with the procurement conformity checklist: identify the exact component and variant before requesting evidence. The second take on ansi bhma a156 13 versus ansi bhma a156 14 applicability is Ansi/bhma A156.13 in the United States Purchasing Practice: What Buyers Are Asked to Produce. The catalogue entry point for this is the smart door locks.

Decision pointANSI/BHMA A156.13 pathANSI/BHMA A156.14 path
Hardware in the purchaseMortise lock bodyPush or pull exit device
Scope checkCurrent published mortise-lock scopeCurrent published exit-device scope
Evidence requestExact body, function and variantExact device, operation and variant
Wrong inferenceExit-device or whole-opening approvalMortise-lock or whole-opening approval
Combined openingSeparate evidence lineSeparate evidence line

This is the smart lock door hardware qualification map. A credential reader does not convert a mortise lock into an exit device, and an exit device does not qualify the lock body. Use ansi-bhma-a156-13 only as the internal cross-reference for the mortise-lock line.

CONFIRM-WITH-LOCAL-AUTHORITY: Confirm current editions, project adoption and opening-specific requirements with the authority having jurisdiction.

flowchart TD
    O[Smart lock door opening] --> L[Mortise lock body]
    O --> E[Push or pull exit device]
    O --> P[Electrical and door assembly]
    L --> A[Check A156.13 current scope]
    E --> B[Check A156.14 current scope]
    P --> C[Check separate project evidence]
    A --> D[Match evidence to exact variant]
    B --> D

Route each component to the right scope

Begin with the purchase line, not the marketing name. The ANSI/BHMA A156.13 mortise lock scope is the scope to check for the lock body; the ANSI/BHMA A156.14 exit device scope is the scope to check for the push or pull device. Neither document should cover the other component.

Where electric locking is present, screen the electrical function against ANSI/BHMA A156.25 and its current scope. If the design uses electromagnetic holding, also screen ANSI/BHMA A156.23. Fire-door, egress and accessibility questions remain opening-specific and need separate verification.

CONFIRM-WITH-LOCAL-CODE-REVIEW: Confirm the applicable fire-door, egress and accessibility requirements for the actual opening with the authority having jurisdiction.

The boundary is decisive: A156.13 addresses a mortise lock; A156.14 addresses an exit device. Both can appear in one tender without either becoming site-wide approval. See Ansi/bhma A156.13 for Smart Locks: Scope, Tests and What the Standard Never Proves for the detailed mortise-lock boundary.

Readers comparing approaches usually start with the smart lock data encryption. That is the same question ansi bhma a156 13 versus ansi bhma a156 14 applicability has to answer here.

Keep four evidence documents apart

The test report versus certificate distinction is essential because they answer different questions.

DocumentWhat it representsEvidence to verify
Test reportSomeone tested a sampleSample identity, standard, edition, results and limits
CertificateA body attests conformityScope, verifiable number, validity and covered variant
Declaration of conformityManufacturer or importer makes its own claimSignatory, date, product identity and responsibility
MarkingA label mark such as CE, UKCA, RCM, KC or G-MarkWhich supporting document applies to this purchase

Certification status remains CONFIRM-PER-SUPPLIER. Use marketing image → self-declared DoC → sample test report → third-party certificate with scope and number → certificate naming the exact SKU/variant on the order → audit and production-control evidence that keeps the result valid after the sample passed. Procurement should target evidence for the exact purchased variant, plus production-control records. For ansi bhma a156 13 versus ansi bhma a156 14 applicability, the position on this ladder is what the purchase decision turns on.

The rungs that decide ansi bhma a156 13 versus ansi bhma a156 14 applicability are the ones issued under ansi bhma a156 13; a file for a different scheme does not move the position on this ladder.

This overlaps with the earlier coverage in the smart lock firmware security. That is the same question ansi bhma a156 13 versus ansi bhma a156 14 applicability has to answer here.CONFIRM-WITH-LOCAL-DOCUMENT-REVIEW: Confirm which declaration, certificate and marking route applies to the specific product and destination.

Build a component-by-component evidence pack

Ask the supplier for one indexed pack rather than a bundle of logos:

  • A component matrix listing the exact lock body, exit device, electrical function, SKU and variants. Use the Office Smart Lock Site Survey to confirm what is physically present.
  • The current proposed edition and scope for each selected standard, with clause references tied to a purchasable configuration.
  • The named report and sample identity. The Reading an ANSI/BHMA A156.13 Test Report Page by Page: A Smart Lock Buyer Walkthrough explains how to read that record.
  • Any certificate scope, number, validity and exact variant coverage. Check class and grade claims with Decoding ANSI/BHMA A156.13 Class and Grade Numbers for Door Hardware.
  • Separate copies or references for the declaration of conformity and any product or label marking.
  • Production-control evidence and the date of the underlying records.

The mortise lock and exit device evidence must occupy two indexed lines. A complete file for one line does not close the other; the ANSI/BHMA A156.13 in a Smart Lock Tender Pack: The Evidence Checklist can be adapted for that structure.

Put scope questions into the RFQ

Use questions that expose gaps before award:

  1. Which exact component, function, construction and variant does each proposed report or certificate cover?
  2. Which current edition and published scope is proposed for A156.13 or A156.14, and why does the component fit?
  3. If both standards are cited, what evidence line covers the lock body and what line covers the exit device?
  4. Which document supports each conformity statement, and where are its scope, number, date and variant details?
  5. What production-control evidence links the tested result to units supplied later?
  6. Who owns each missing record, and by what date will it be supplied?

Do not ask for a generic “A156.13 compliant smart lock.” That wording hides whether the supplier is discussing the mortise lock body, an exit device or an electrically operated assembly.

Close the qualification with a decision matrix

FindingProcurement record
Mortise lock body onlyA156.13 evidence line; A156.14 not selected for the body
Exit device onlyA156.14 evidence line; A156.13 not selected for the device
Both on one openingTwo evidence lines plus an installed-assembly review
Electrical function involvedSeparate adjacent-scope evidence and integration review

Do not release qualification until every purchased component maps to exact evidence and every gap has an owner and date. A supplier may hold strong evidence for the mortise lock while leaving the exit device or electrical function unresolved. Record those items as open qualification actions, never as approval of the whole opening.

The requirement is ready for request a quote once it is written down.